SLAC Magnetic Measurements
Date: 03-03-1995
Time: 14:00:55

Magnet Name: 2Q10-07
Project: PEP II Injection Line
Test Stand: Rotating Coil Stand 2
Measurement Coil: DC100
Operator: steven garcia
Run Number: 1
Comment: standard measurement

Standardization Currents (A):
   160.0     2.0   160.0     2.0   160.0     2.0

Test Currents (A):
    10.0    30.0    45.0    60.0    75.0    90.0   100.0
   110.0   125.0   140.0   160.0   130.0   100.0    60.0


                      HARMONICS MEASUREMENTS

Date: 03-03-1995
Time: 14:27:22
Magnet Name: 2Q10-07
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  60.01234  +-  5.458484E-05  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   5.350   0.018  175.78    0.09   1.479   0.004
  2 361.772   0.159  -48.41    0.01 100.000   0.000
  3   0.662   0.016   -1.67    0.43   0.183   0.005
  4   0.191   0.032   41.27    0.91   0.053   0.009
  5   0.264   0.020   -5.34    0.95   0.073   0.005
  6   0.342   0.011   -7.78    1.06   0.094   0.003
  7   0.068   0.030  -13.24    8.73   0.019   0.008
  8   0.341   0.078  -19.67    0.69   0.094   0.022
  9   0.241   0.011   -3.00    0.51   0.066   0.003
 10   0.806   0.003    5.01    0.03   0.223   0.001
 11   0.013   0.005  -11.06    2.46   0.004   0.002
 12   0.033   0.004   13.46    0.40   0.009   0.001
 13   0.041   0.002   -3.10    0.32   0.011   0.001
 14   0.147   0.004    2.97    0.12   0.041   0.001
 15   0.018   0.004    6.05    1.41   0.005   0.001
 16   0.013   0.003   -4.46    1.82   0.004   0.001


The magnetic center is at
X =    20.7 +-     0.5 microns
Y =  -280.2 +-     0.9 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non-lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 03-03-1995
Time: 14:43:34
Magnet Name: 2Q10-07
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  99.99563  +-  2.789428E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   9.059   0.008  175.75    0.09   1.504   0.001
  2 602.315   0.243  -48.41    0.01 100.000   0.000
  3   1.104   0.046   -1.52    0.66   0.183   0.008
  4   0.365   0.059   41.75    1.85   0.061   0.010
  5   0.418   0.038   -2.91    0.45   0.069   0.006
  6   0.496   0.103   -8.23    2.18   0.082   0.017
  7   0.149   0.035   -4.29    6.81   0.025   0.006
  8   0.438   0.149  -18.66    1.13   0.073   0.025
  9   0.367   0.029   -2.89    0.44   0.061   0.005
 10   1.333   0.016    5.04    0.16   0.221   0.003
 11   0.041   0.011  -10.68    1.28   0.007   0.002
 12   0.055   0.005   13.66    0.40   0.009   0.001
 13   0.066   0.008   -3.62    0.19   0.011   0.001
 14   0.257   0.006    3.03    0.13   0.043   0.001
 15   0.029   0.010    4.60    0.34   0.005   0.002
 16   0.017   0.004   -4.92    2.35   0.003   0.001


The magnetic center is at
X =    21.2 +-     0.4 microns
Y =  -284.9 +-     0.3 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non-lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 03-03-1995
Time: 14:59:45
Magnet Name: 2Q10-07
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  139.9973  +-  3.17148E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1  12.722   0.021  175.72    0.06   1.512   0.002
  2 841.285   0.313  -48.40    0.01 100.000   0.000
  3   1.519   0.034   -1.97    0.36   0.181   0.004
  4   0.468   0.055   41.80    0.77   0.056   0.006
  5   0.544   0.052   -6.13    1.42   0.065   0.006
  6   0.699   0.155   -8.70    1.55   0.083   0.018
  7   0.150   0.085   -5.63    2.76   0.018   0.010
  8   0.699   0.129  -15.60    1.08   0.083   0.015
  9   0.553   0.027   -2.44    0.32   0.066   0.003
 10   1.847   0.014    5.00    0.08   0.220   0.002
 11   0.031   0.004  -11.98    2.91   0.004   0.000
 12   0.078   0.009   13.90    0.25   0.009   0.001
 13   0.094   0.005   -3.40    0.14   0.011   0.001
 14   0.348   0.010    3.14    0.18   0.041   0.001
 15   0.038   0.009    5.33    1.77   0.005   0.001
 16   0.036   0.015   -5.67    1.27   0.004   0.002


The magnetic center is at
X =    21.4 +-     0.3 microns
Y =  -286.5 +-     0.5 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non-lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       


           SUMMARY OF THE CALCULATIONS AND CONVENTIONS USED


Calculation of GL using a double coil (assumed flat):
V2 = (Nturns * velocity * B2 * L)_1 + (Nturns * velocity * B2 * L)_2
   = (Nturns1 * Rcoil1 * ang_freq * GL * Rcoil1)
          + (Nturns2 * Rcoil2 * ang_freq * GL * Rcoil2)
   = (Nturns1 * Rcoil1^2 + Nturns2 * Rcoil2^2) * ang_freq * GL
If Nturns1 = Nturns2 == Nturns12, then
V2 = Nturns12 * (Rcoil1^2 + Rcoil2^2) * ang_freq * GL
Let Reff^2 = Rcoil1^2 + Rcoil2^2, then
V2 = Nturns12 * Reff^2 * ang_freq * GL
Or,
GL = V2 / (Nturns12 * Reff^2 * ang_freq)


Calculation of the harmonics:
The integrated radial field for the n'th harmonic at the
coil radius is given by
BLn(th) = BLn * cos(n*(th - THspole))
The coil voltage is V = Nturns * v_theta * B_r * L
Vn(th) = Nturns * velocity * BLn(th)
       = Nturns * Rcoil * ang_freq * BLn * cos(n*(th - THspole))
The FFT gives Vn and PhiVn in the formula
Vn(i) = Vn * cos(n*2pi*i/N + PhiVn)
Then,
Vn = Nturns * Rcoil * ang_freq * BLn
PhiVn = - n * THspole
Or,
BLn = Vn / (Nturns * Rcoil * ang_freq)
THspole = - PhiVn / n


Calculation of the magnetic center:
Xcenter = - (1/GL) * BL1 * sin(THspole1)
Ycenter = - (1/GL) * BL1 * cos(THspole1)