SLAC Magnetic Measurements Date: 07-12-1994 Time: 09:03:31 Magnet Name: 177 Test Operator: PDR Test Stand: D2 Apparatus: Coil 2 Run Number: 1 Comment: Standardization and Harmonic Measurements Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 Coil 0 Ibefore = 650.102 Iafter = 650.09 VT+- = 0.95664 -0.95670 0.95683 -0.95672 0.95674 -0.95673 VT+- = 0.95685 -0.95678 0.95682 -0.95673 Average: VT = .9567538 +- 6.233464E-05 Coil 2 Ibefore = 650.1 Iafter = 650.098 VT+- = 0.95375 -0.95376 0.95372 -0.95369 0.95377 -0.95377 VT+- = 0.95389 -0.95373 0.95379 -0.95371 Average: VT = .9537566 +- 5.207786E-05 Coil 0 Ibefore = 650.098 Iafter = 650.106 VT+- = 0.95682 -0.95676 0.95677 -0.95678 0.95676 -0.95675 VT+- = 0.95680 -0.95679 0.95682 -0.95675 Average: VT = .9567792 +- 2.439896E-05 Coil 2 Ibefore = 650.102 Iafter = 650.098 VT+- = 0.95373 -0.95361 0.95385 -0.95373 0.95378 -0.95361 VT+- = 0.95367 -0.95370 0.95371 -0.95383 Average: VT = .9537212 +- 7.628687E-05 Coil 0 Ibefore = 650.11 Iafter = 650.094 VT+- = 0.95675 -0.95679 0.95670 -0.95675 0.95676 -0.95672 VT+- = 0.95681 -0.95676 0.95676 -0.95672 Average: VT = .956753 +- 3.081102E-05 Coil 2 Ibefore = 650.104 Iafter = 650.098 VT+- = 0.95366 -0.95359 0.95372 -0.95372 0.95369 -0.95372 VT+- = 0.95365 -0.95356 0.95379 -0.95359 Average: VT = .9536684 +- 6.966306E-05 BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.10 1 0.95675 0.00006 0.99188 0.00006 650.10 2 0.95678 0.00002 0.99190 0.00003 650.10 3 0.95675 0.00003 0.99188 0.00003 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.10 1 0.95470 0.00005 0.98975 0.00005 0.99785 0.00008 650.10 2 0.95467 0.00008 0.98971 0.00008 0.99779 0.00008 650.10 3 0.95461 0.00007 0.98966 0.00007 0.99776 0.00008