SLAC Magnetic Measurements Date: 12-15-1994 Time: 14:52:35 Magnet Name: 082 Test Operator: bmd Test Stand: D1 Apparatus: Coil 1 Run Number: 1 Comment: Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 FIELD UNIFORMITY MEASUREMENTS BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.20 1 0.95682 0.00007 0.99325 0.00007 650.20 2 0.95681 0.00005 0.99325 0.00005 650.20 3 0.95681 0.00006 0.99324 0.00006 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.19 1 0.95636 0.00008 0.99278 0.00008 0.99954 0.00011 650.19 2 0.95626 0.00006 0.99267 0.00007 0.99944 0.00009 650.20 3 0.95624 0.00009 0.99265 0.00009 0.99941 0.00011