SLAC Magnetic Measurements Date: 03-09-1995 Time: 09:42:39 Magnet Name: 048 Test Operator: bmd Test Stand: D2 Apparatus: Coil 2 Run Number: 2 Comment: Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 FIELD UNIFORMITY MEASUREMENTS BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.23 1 0.95695 0.00009 0.99339 0.00010 650.25 2 0.95696 0.00012 0.99339 0.00012 650.24 3 0.95697 0.00007 0.99341 0.00007 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.24 1 0.95524 0.00004 0.99161 0.00004 0.99820 0.00010 650.24 2 0.95516 0.00005 0.99153 0.00005 0.99813 0.00013 650.24 3 0.95511 0.00005 0.99148 0.00005 0.99806 0.00008