SLAC Magnetic Measurements Date: 12-22-1994 Time: 13:31:17 Magnet Name: 042 Test Operator: bmd Test Stand: D1 Apparatus: Coil 1 Run Number: 3 Comment: Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 FIELD UNIFORMITY MEASUREMENTS BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.18 1 0.95673 0.00005 0.99316 0.00005 650.19 2 0.95672 0.00009 0.99314 0.00009 650.19 3 0.95674 0.00004 0.99316 0.00005 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.19 1 0.95497 0.00006 0.99133 0.00006 0.99815 0.00008 650.20 2 0.95494 0.00007 0.99129 0.00007 0.99813 0.00011 650.20 3 0.95493 0.00008 0.99129 0.00008 0.99811 0.00010