SLAC Magnetic Measurements Date: 01-27-2004 Time: 15:26:46 Project: Orion Magnet Type: solenoid Magnet Name: Ecomp Serial Number: Run Number: 12 Measurement Device: B9900 Hall probe Operator: sa Comment: Bz vs z, x = -10 mm, y = 0 Standardization: 4 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 50.0 150.0 220.0 15:26:59 Stage Zeroed 15:26:59 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:27:56 Move Stage, position = -0.250000 15:28:38 Hall Probe Zeroed 15:29:00 Hall Probe Type Being Used, type = B9900 15:29:57 Move Stage, position = 0.000000 15:29:58 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:30:02 Hall Probe Range Set, range = 5 15:30:02 Magnet current ramping to 220.0000 A... 15:32:38 Magnet current ramping to 0.0000 A... 15:35:14 Magnet current ramping to 220.0000 A... 15:37:50 Magnet current ramping to 0.0000 A... 15:40:26 Magnet current ramping to 220.0000 A... 15:43:02 Magnet current ramping to 0.0000 A... 15:45:38 Magnet current ramping to 220.0000 A... 15:48:14 Magnet current ramping to 0.0000 A... 15:50:50 Magnet current ramping to 50.0000 A... 15:52:45 Move Stage, position = -0.250000 15:52:47 Stage Position Measurement, pos = -0.250000 m 15:52:48 Magnet Current, Imag = 49.9266 A Vtrans = 0.499266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:49 Hall Probe Field Measurement, B = -0.000200 T 15:52:56 Move Stage, position = -0.240000 15:52:57 Stage Position Measurement, pos = -0.240000 m 15:52:58 Magnet Current, Imag = 49.9265 A Vtrans = 0.499265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:59 Hall Probe Field Measurement, B = -0.000200 T 15:53:06 Move Stage, position = -0.230000 15:53:08 Stage Position Measurement, pos = -0.230000 m 15:53:09 Magnet Current, Imag = 49.9268 A Vtrans = 0.499268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:10 Hall Probe Field Measurement, B = -0.000200 T 15:53:17 Move Stage, position = -0.220000 15:53:18 Stage Position Measurement, pos = -0.220000 m 15:53:20 Magnet Current, Imag = 49.9294 A Vtrans = 0.499294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:20 Hall Probe Field Measurement, B = -0.000300 T 15:53:27 Move Stage, position = -0.210000 15:53:29 Stage Position Measurement, pos = -0.210000 m 15:53:30 Magnet Current, Imag = 49.9282 A Vtrans = 0.499282 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:30 Hall Probe Field Measurement, B = -0.000300 T 15:53:37 Move Stage, position = -0.200000 15:53:39 Stage Position Measurement, pos = -0.200000 m 15:53:40 Magnet Current, Imag = 49.9252 A Vtrans = 0.499252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:41 Hall Probe Field Measurement, B = -0.000400 T 15:53:48 Move Stage, position = -0.190000 15:53:49 Stage Position Measurement, pos = -0.190000 m 15:53:51 Magnet Current, Imag = 49.9263 A Vtrans = 0.499263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:51 Hall Probe Field Measurement, B = -0.000600 T 15:53:58 Move Stage, position = -0.180000 15:54:00 Stage Position Measurement, pos = -0.180000 m 15:54:01 Magnet Current, Imag = 49.9277 A Vtrans = 0.499277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:02 Hall Probe Field Measurement, B = -0.000800 T 15:54:09 Move Stage, position = -0.170000 15:54:10 Stage Position Measurement, pos = -0.170000 m 15:54:11 Magnet Current, Imag = 49.9268 A Vtrans = 0.499268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:12 Hall Probe Field Measurement, B = -0.001100 T 15:54:19 Move Stage, position = -0.160000 15:54:21 Stage Position Measurement, pos = -0.160000 m 15:54:22 Magnet Current, Imag = 49.9303 A Vtrans = 0.499303 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:22 Hall Probe Field Measurement, B = -0.001700 T 15:54:29 Move Stage, position = -0.150000 15:54:31 Stage Position Measurement, pos = -0.150000 m 15:54:32 Magnet Current, Imag = 49.9259 A Vtrans = 0.499259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:33 Hall Probe Field Measurement, B = -0.002600 T 15:54:40 Move Stage, position = -0.140000 15:54:41 Stage Position Measurement, pos = -0.140000 m 15:54:43 Magnet Current, Imag = 49.9261 A Vtrans = 0.499261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:43 Hall Probe Field Measurement, B = -0.004200 T 15:54:50 Move Stage, position = -0.130000 15:54:52 Stage Position Measurement, pos = -0.130000 m 15:54:53 Magnet Current, Imag = 49.9265 A Vtrans = 0.499265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:53 Hall Probe Field Measurement, B = -0.007100 T 15:55:01 Move Stage, position = -0.120000 15:55:02 Stage Position Measurement, pos = -0.120000 m 15:55:03 Magnet Current, Imag = 49.9284 A Vtrans = 0.499284 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:04 Hall Probe Field Measurement, B = -0.012400 T 15:55:11 Move Stage, position = -0.110000 15:55:13 Stage Position Measurement, pos = -0.110000 m 15:55:14 Magnet Current, Imag = 49.9262 A Vtrans = 0.499262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:14 Hall Probe Field Measurement, B = -0.021200 T 15:55:21 Move Stage, position = -0.100000 15:55:23 Stage Position Measurement, pos = -0.100000 m 15:55:24 Magnet Current, Imag = 49.9300 A Vtrans = 0.499300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:25 Hall Probe Field Measurement, B = -0.033300 T 15:55:32 Move Stage, position = -0.090000 15:55:33 Stage Position Measurement, pos = -0.090000 m 15:55:35 Magnet Current, Imag = 49.9278 A Vtrans = 0.499278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:35 Hall Probe Field Measurement, B = -0.046500 T 15:55:42 Move Stage, position = -0.080000 15:55:44 Stage Position Measurement, pos = -0.080000 m 15:55:45 Magnet Current, Imag = 49.9308 A Vtrans = 0.499308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:45 Hall Probe Field Measurement, B = -0.056900 T 15:55:52 Move Stage, position = -0.070000 15:55:54 Stage Position Measurement, pos = -0.070000 m 15:55:55 Magnet Current, Imag = 49.9250 A Vtrans = 0.499250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:56 Hall Probe Field Measurement, B = -0.064000 T 15:56:03 Move Stage, position = -0.060000 15:56:05 Stage Position Measurement, pos = -0.060000 m 15:56:06 Magnet Current, Imag = 49.9273 A Vtrans = 0.499273 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:06 Hall Probe Field Measurement, B = -0.068400 T 15:56:13 Move Stage, position = -0.050000 15:56:15 Stage Position Measurement, pos = -0.050000 m 15:56:16 Magnet Current, Imag = 49.9267 A Vtrans = 0.499267 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:17 Hall Probe Field Measurement, B = -0.071000 T 15:56:24 Move Stage, position = -0.040000 15:56:25 Stage Position Measurement, pos = -0.040000 m 15:56:27 Magnet Current, Imag = 49.9238 A Vtrans = 0.499238 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:27 Hall Probe Field Measurement, B = -0.072400 T 15:56:34 Move Stage, position = -0.030000 15:56:36 Stage Position Measurement, pos = -0.030000 m 15:56:37 Magnet Current, Imag = 49.9270 A Vtrans = 0.499270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:37 Hall Probe Field Measurement, B = -0.073200 T 15:56:44 Move Stage, position = -0.020000 15:56:46 Stage Position Measurement, pos = -0.020000 m 15:56:47 Magnet Current, Imag = 49.9289 A Vtrans = 0.499289 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:48 Hall Probe Field Measurement, B = -0.074000 T 15:56:55 Move Stage, position = -0.010000 15:56:57 Stage Position Measurement, pos = -0.010000 m 15:56:58 Magnet Current, Imag = 49.9281 A Vtrans = 0.499281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:58 Hall Probe Field Measurement, B = -0.074400 T 15:57:05 Move Stage, position = 0.000000 15:57:07 Stage Position Measurement, pos = 0.000000 m 15:57:08 Magnet Current, Imag = 49.9248 A Vtrans = 0.499248 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:09 Hall Probe Field Measurement, B = -0.075000 T 15:57:16 Move Stage, position = 0.010000 15:57:17 Stage Position Measurement, pos = 0.010000 m 15:57:19 Magnet Current, Imag = 49.9232 A Vtrans = 0.499232 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:19 Hall Probe Field Measurement, B = -0.075500 T 15:57:26 Move Stage, position = 0.020000 15:57:28 Stage Position Measurement, pos = 0.020000 m 15:57:29 Magnet Current, Imag = 49.9249 A Vtrans = 0.499249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:29 Hall Probe Field Measurement, B = -0.075700 T 15:57:36 Move Stage, position = 0.030000 15:57:38 Stage Position Measurement, pos = 0.030000 m 15:57:39 Magnet Current, Imag = 49.9278 A Vtrans = 0.499278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:40 Hall Probe Field Measurement, B = -0.075100 T 15:57:47 Move Stage, position = 0.040000 15:57:49 Stage Position Measurement, pos = 0.040000 m 15:57:50 Magnet Current, Imag = 49.9262 A Vtrans = 0.499262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:50 Hall Probe Field Measurement, B = -0.073500 T 15:57:57 Move Stage, position = 0.050000 15:57:59 Stage Position Measurement, pos = 0.050000 m 15:58:00 Magnet Current, Imag = 49.9279 A Vtrans = 0.499279 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:01 Hall Probe Field Measurement, B = -0.071100 T 15:58:08 Move Stage, position = 0.060000 15:58:09 Stage Position Measurement, pos = 0.060000 m 15:58:11 Magnet Current, Imag = 49.9272 A Vtrans = 0.499272 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:11 Hall Probe Field Measurement, B = -0.068000 T 15:58:18 Move Stage, position = 0.070000 15:58:20 Stage Position Measurement, pos = 0.070000 m 15:58:21 Magnet Current, Imag = 49.9248 A Vtrans = 0.499248 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:21 Hall Probe Field Measurement, B = -0.063000 T 15:58:28 Move Stage, position = 0.080000 15:58:30 Stage Position Measurement, pos = 0.080000 m 15:58:31 Magnet Current, Imag = 49.9301 A Vtrans = 0.499301 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:32 Hall Probe Field Measurement, B = -0.055700 T 15:58:39 Move Stage, position = 0.090000 15:58:41 Stage Position Measurement, pos = 0.090000 m 15:58:42 Magnet Current, Imag = 49.9280 A Vtrans = 0.499280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:42 Hall Probe Field Measurement, B = -0.044900 T 15:58:49 Move Stage, position = 0.100000 15:58:51 Stage Position Measurement, pos = 0.100000 m 15:58:52 Magnet Current, Imag = 49.9264 A Vtrans = 0.499264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:53 Hall Probe Field Measurement, B = -0.031800 T 15:59:00 Move Stage, position = 0.110000 15:59:01 Stage Position Measurement, pos = 0.110000 m 15:59:03 Magnet Current, Imag = 49.9239 A Vtrans = 0.499239 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:04 Hall Probe Field Measurement, B = -0.019900 T 15:59:11 Move Stage, position = 0.120000 15:59:13 Stage Position Measurement, pos = 0.120000 m 15:59:14 Magnet Current, Imag = 49.9251 A Vtrans = 0.499251 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:14 Hall Probe Field Measurement, B = -0.011700 T 15:59:21 Move Stage, position = 0.130000 15:59:23 Stage Position Measurement, pos = 0.130000 m 15:59:24 Magnet Current, Imag = 49.9231 A Vtrans = 0.499231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:25 Hall Probe Field Measurement, B = -0.006700 T 15:59:32 Move Stage, position = 0.140000 15:59:33 Stage Position Measurement, pos = 0.140000 m 15:59:35 Magnet Current, Imag = 49.9254 A Vtrans = 0.499254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:35 Hall Probe Field Measurement, B = -0.004000 T 15:59:42 Move Stage, position = 0.150000 15:59:44 Stage Position Measurement, pos = 0.150000 m 15:59:45 Magnet Current, Imag = 49.9241 A Vtrans = 0.499241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:45 Hall Probe Field Measurement, B = -0.002500 T 15:59:53 Move Stage, position = 0.160000 15:59:54 Stage Position Measurement, pos = 0.160000 m 15:59:55 Magnet Current, Imag = 49.9273 A Vtrans = 0.499273 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:56 Hall Probe Field Measurement, B = -0.001600 T 16:00:03 Move Stage, position = 0.170000 16:00:05 Stage Position Measurement, pos = 0.170000 m 16:00:06 Magnet Current, Imag = 49.9284 A Vtrans = 0.499284 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:06 Hall Probe Field Measurement, B = -0.001100 T 16:00:13 Move Stage, position = 0.180000 16:00:15 Stage Position Measurement, pos = 0.180000 m 16:00:16 Magnet Current, Imag = 49.9277 A Vtrans = 0.499277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:17 Hall Probe Field Measurement, B = -0.000700 T 16:00:24 Move Stage, position = 0.190000 16:00:25 Stage Position Measurement, pos = 0.190000 m 16:00:27 Magnet Current, Imag = 49.9263 A Vtrans = 0.499263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:27 Hall Probe Field Measurement, B = -0.000600 T 16:00:34 Move Stage, position = 0.200000 16:00:36 Stage Position Measurement, pos = 0.200000 m 16:00:37 Magnet Current, Imag = 49.9260 A Vtrans = 0.499260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:37 Hall Probe Field Measurement, B = -0.000400 T 16:00:45 Move Stage, position = 0.210000 16:00:46 Stage Position Measurement, pos = 0.210000 m 16:00:47 Magnet Current, Imag = 49.9279 A Vtrans = 0.499279 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:48 Hall Probe Field Measurement, B = -0.000300 T 16:00:55 Move Stage, position = 0.220000 16:00:57 Stage Position Measurement, pos = 0.220000 m 16:00:58 Magnet Current, Imag = 49.9282 A Vtrans = 0.499282 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:58 Hall Probe Field Measurement, B = -0.000300 T 16:01:05 Move Stage, position = 0.230000 16:01:07 Stage Position Measurement, pos = 0.230000 m 16:01:08 Magnet Current, Imag = 49.9258 A Vtrans = 0.499258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:09 Hall Probe Field Measurement, B = -0.000200 T 16:01:16 Move Stage, position = 0.240000 16:01:17 Stage Position Measurement, pos = 0.240000 m 16:01:19 Magnet Current, Imag = 49.9262 A Vtrans = 0.499262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:19 Hall Probe Field Measurement, B = -0.000200 T 16:01:26 Move Stage, position = 0.250000 16:01:28 Stage Position Measurement, pos = 0.250000 m 16:01:29 Magnet Current, Imag = 49.9278 A Vtrans = 0.499278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:29 Hall Probe Field Measurement, B = -0.000200 T 16:02:25 Move Stage, position = 0.000000 16:02:25 Magnet current ramping to 150.0000 A... 16:04:48 Move Stage, position = -0.250000 16:04:49 Stage Position Measurement, pos = -0.250000 m 16:04:51 Magnet Current, Imag = 149.9524 A Vtrans = 1.499524 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:51 Hall Probe Field Measurement, B = -0.000500 T 16:04:58 Move Stage, position = -0.240000 16:05:00 Stage Position Measurement, pos = -0.240000 m 16:05:01 Magnet Current, Imag = 149.9492 A Vtrans = 1.499492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:01 Hall Probe Field Measurement, B = -0.000600 T 16:05:09 Move Stage, position = -0.230000 16:05:10 Stage Position Measurement, pos = -0.230000 m 16:05:11 Magnet Current, Imag = 149.9491 A Vtrans = 1.499491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:12 Hall Probe Field Measurement, B = -0.000700 T 16:05:19 Move Stage, position = -0.220000 16:05:21 Stage Position Measurement, pos = -0.220000 m 16:05:22 Magnet Current, Imag = 149.9489 A Vtrans = 1.499489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:22 Hall Probe Field Measurement, B = -0.000800 T 16:05:29 Move Stage, position = -0.210000 16:05:31 Stage Position Measurement, pos = -0.210000 m 16:05:32 Magnet Current, Imag = 149.9517 A Vtrans = 1.499517 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:33 Hall Probe Field Measurement, B = -0.001100 T 16:05:40 Move Stage, position = -0.200000 16:05:41 Stage Position Measurement, pos = -0.200000 m 16:05:43 Magnet Current, Imag = 149.9583 A Vtrans = 1.499583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:43 Hall Probe Field Measurement, B = -0.001300 T 16:05:50 Move Stage, position = -0.190000 16:05:52 Stage Position Measurement, pos = -0.190000 m 16:05:53 Magnet Current, Imag = 149.9482 A Vtrans = 1.499482 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:54 Hall Probe Field Measurement, B = -0.001700 T 16:06:02 Move Stage, position = -0.180000 16:06:03 Stage Position Measurement, pos = -0.180000 m 16:06:04 Magnet Current, Imag = 149.9502 A Vtrans = 1.499502 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:05 Hall Probe Field Measurement, B = -0.002500 T 16:06:12 Move Stage, position = -0.170000 16:06:14 Stage Position Measurement, pos = -0.170000 m 16:06:15 Magnet Current, Imag = 149.9489 A Vtrans = 1.499489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:15 Hall Probe Field Measurement, B = -0.003300 T 16:06:22 Move Stage, position = -0.160000 16:06:24 Stage Position Measurement, pos = -0.160000 m 16:06:25 Magnet Current, Imag = 149.9514 A Vtrans = 1.499514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:26 Hall Probe Field Measurement, B = -0.004800 T 16:06:33 Move Stage, position = -0.150000 16:06:34 Stage Position Measurement, pos = -0.150000 m 16:06:36 Magnet Current, Imag = 149.9518 A Vtrans = 1.499518 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:36 Hall Probe Field Measurement, B = -0.007600 T 16:06:43 Move Stage, position = -0.140000 16:06:45 Stage Position Measurement, pos = -0.140000 m 16:06:46 Magnet Current, Imag = 149.9423 A Vtrans = 1.499423 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:46 Hall Probe Field Measurement, B = -0.012400 T 16:06:54 Move Stage, position = -0.130000 16:06:55 Stage Position Measurement, pos = -0.130000 m 16:06:56 Magnet Current, Imag = 149.9480 A Vtrans = 1.499480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:57 Hall Probe Field Measurement, B = -0.021200 T 16:07:04 Move Stage, position = -0.120000 16:07:06 Stage Position Measurement, pos = -0.120000 m 16:07:07 Magnet Current, Imag = 149.9496 A Vtrans = 1.499496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:07 Hall Probe Field Measurement, B = -0.037000 T 16:07:14 Move Stage, position = -0.110000 16:07:16 Stage Position Measurement, pos = -0.110000 m 16:07:17 Magnet Current, Imag = 149.9496 A Vtrans = 1.499496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:18 Hall Probe Field Measurement, B = -0.063400 T 16:07:25 Move Stage, position = -0.100000 16:07:26 Stage Position Measurement, pos = -0.100000 m 16:07:28 Magnet Current, Imag = 149.9513 A Vtrans = 1.499513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:28 Hall Probe Field Measurement, B = -0.099900 T 16:07:35 Move Stage, position = -0.090000 16:07:37 Stage Position Measurement, pos = -0.090000 m 16:07:38 Magnet Current, Imag = 149.9540 A Vtrans = 1.499540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:39 Hall Probe Field Measurement, B = -0.139300 T 16:07:46 Move Stage, position = -0.080000 16:07:47 Stage Position Measurement, pos = -0.080000 m 16:07:48 Magnet Current, Imag = 149.9483 A Vtrans = 1.499483 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:49 Hall Probe Field Measurement, B = -0.170600 T 16:07:56 Move Stage, position = -0.070000 16:07:58 Stage Position Measurement, pos = -0.070000 m 16:07:59 Magnet Current, Imag = 149.9531 A Vtrans = 1.499531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:59 Hall Probe Field Measurement, B = -0.191900 T 16:08:06 Move Stage, position = -0.060000 16:08:08 Stage Position Measurement, pos = -0.060000 m 16:08:09 Magnet Current, Imag = 149.9533 A Vtrans = 1.499533 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:10 Hall Probe Field Measurement, B = -0.205100 T 16:08:17 Move Stage, position = -0.050000 16:08:19 Stage Position Measurement, pos = -0.050000 m 16:08:20 Magnet Current, Imag = 149.9529 A Vtrans = 1.499529 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:20 Hall Probe Field Measurement, B = -0.212700 T 16:08:27 Move Stage, position = -0.040000 16:08:29 Stage Position Measurement, pos = -0.040000 m 16:08:30 Magnet Current, Imag = 149.9514 A Vtrans = 1.499514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:31 Hall Probe Field Measurement, B = -0.217000 T 16:08:38 Move Stage, position = -0.030000 16:08:39 Stage Position Measurement, pos = -0.030000 m 16:08:41 Magnet Current, Imag = 149.9479 A Vtrans = 1.499479 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:41 Hall Probe Field Measurement, B = -0.219600 T 16:08:48 Move Stage, position = -0.020000 16:08:50 Stage Position Measurement, pos = -0.020000 m 16:08:51 Magnet Current, Imag = 149.9505 A Vtrans = 1.499505 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:51 Hall Probe Field Measurement, B = -0.221500 T 16:08:59 Move Stage, position = -0.010000 16:09:00 Stage Position Measurement, pos = -0.010000 m 16:09:01 Magnet Current, Imag = 149.9494 A Vtrans = 1.499494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:02 Hall Probe Field Measurement, B = -0.223100 T 16:09:09 Move Stage, position = 0.000000 16:09:11 Stage Position Measurement, pos = 0.000000 m 16:09:12 Magnet Current, Imag = 149.9522 A Vtrans = 1.499522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:12 Hall Probe Field Measurement, B = -0.224600 T 16:09:19 Move Stage, position = 0.010000 16:09:21 Stage Position Measurement, pos = 0.010000 m 16:09:22 Magnet Current, Imag = 149.9532 A Vtrans = 1.499532 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:23 Hall Probe Field Measurement, B = -0.226400 T 16:09:30 Move Stage, position = 0.020000 16:09:31 Stage Position Measurement, pos = 0.020000 m 16:09:33 Magnet Current, Imag = 149.9507 A Vtrans = 1.499507 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:33 Hall Probe Field Measurement, B = -0.227100 T 16:09:40 Move Stage, position = 0.030000 16:09:42 Stage Position Measurement, pos = 0.030000 m 16:09:43 Magnet Current, Imag = 149.9487 A Vtrans = 1.499487 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:44 Hall Probe Field Measurement, B = -0.225200 T 16:09:51 Move Stage, position = 0.040000 16:09:52 Stage Position Measurement, pos = 0.040000 m 16:09:53 Magnet Current, Imag = 149.9482 A Vtrans = 1.499482 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:54 Hall Probe Field Measurement, B = -0.220400 T 16:10:01 Move Stage, position = 0.050000 16:10:03 Stage Position Measurement, pos = 0.050000 m 16:10:04 Magnet Current, Imag = 149.9485 A Vtrans = 1.499485 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:04 Hall Probe Field Measurement, B = -0.213400 T 16:10:11 Move Stage, position = 0.060000 16:10:13 Stage Position Measurement, pos = 0.060000 m 16:10:14 Magnet Current, Imag = 149.9464 A Vtrans = 1.499464 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:15 Hall Probe Field Measurement, B = -0.203900 T 16:10:22 Move Stage, position = 0.070000 16:10:24 Stage Position Measurement, pos = 0.070000 m 16:10:25 Magnet Current, Imag = 149.9516 A Vtrans = 1.499516 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:25 Hall Probe Field Measurement, B = -0.189000 T 16:10:32 Move Stage, position = 0.080000 16:10:34 Stage Position Measurement, pos = 0.080000 m 16:10:35 Magnet Current, Imag = 149.9530 A Vtrans = 1.499530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:36 Hall Probe Field Measurement, B = -0.166700 T 16:10:43 Move Stage, position = 0.090000 16:10:44 Stage Position Measurement, pos = 0.090000 m 16:10:46 Magnet Current, Imag = 149.9491 A Vtrans = 1.499491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:46 Hall Probe Field Measurement, B = -0.134300 T 16:10:53 Move Stage, position = 0.100000 16:10:55 Stage Position Measurement, pos = 0.100000 m 16:10:56 Magnet Current, Imag = 149.9530 A Vtrans = 1.499530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:56 Hall Probe Field Measurement, B = -0.095300 T 16:11:04 Move Stage, position = 0.110000 16:11:05 Stage Position Measurement, pos = 0.110000 m 16:11:06 Magnet Current, Imag = 149.9511 A Vtrans = 1.499511 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:07 Hall Probe Field Measurement, B = -0.059700 T 16:11:14 Move Stage, position = 0.120000 16:11:16 Stage Position Measurement, pos = 0.120000 m 16:11:17 Magnet Current, Imag = 149.9541 A Vtrans = 1.499541 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:17 Hall Probe Field Measurement, B = -0.034700 T 16:11:24 Move Stage, position = 0.130000 16:11:26 Stage Position Measurement, pos = 0.130000 m 16:11:27 Magnet Current, Imag = 149.9482 A Vtrans = 1.499482 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:28 Hall Probe Field Measurement, B = -0.019900 T 16:11:35 Move Stage, position = 0.140000 16:11:36 Stage Position Measurement, pos = 0.140000 m 16:11:38 Magnet Current, Imag = 149.9506 A Vtrans = 1.499506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:38 Hall Probe Field Measurement, B = -0.011700 T 16:11:45 Move Stage, position = 0.150000 16:11:47 Stage Position Measurement, pos = 0.150000 m 16:11:48 Magnet Current, Imag = 149.9544 A Vtrans = 1.499544 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:49 Hall Probe Field Measurement, B = -0.007200 T 16:11:56 Move Stage, position = 0.160000 16:11:57 Stage Position Measurement, pos = 0.160000 m 16:11:59 Magnet Current, Imag = 149.9528 A Vtrans = 1.499528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:59 Hall Probe Field Measurement, B = -0.004600 T 16:12:06 Move Stage, position = 0.170000 16:12:08 Stage Position Measurement, pos = 0.170000 m 16:12:09 Magnet Current, Imag = 149.9501 A Vtrans = 1.499501 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:10 Hall Probe Field Measurement, B = -0.003200 T 16:12:17 Move Stage, position = 0.180000 16:12:18 Stage Position Measurement, pos = 0.180000 m 16:12:20 Magnet Current, Imag = 149.9476 A Vtrans = 1.499476 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:20 Hall Probe Field Measurement, B = -0.002200 T 16:12:27 Move Stage, position = 0.190000 16:12:29 Stage Position Measurement, pos = 0.190000 m 16:12:30 Magnet Current, Imag = 149.9524 A Vtrans = 1.499524 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:30 Hall Probe Field Measurement, B = -0.001700 T 16:12:38 Move Stage, position = 0.200000 16:12:39 Stage Position Measurement, pos = 0.200000 m 16:12:40 Magnet Current, Imag = 149.9473 A Vtrans = 1.499473 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:41 Hall Probe Field Measurement, B = -0.001300 T 16:12:48 Move Stage, position = 0.210000 16:12:50 Stage Position Measurement, pos = 0.210000 m 16:12:51 Magnet Current, Imag = 149.9549 A Vtrans = 1.499549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:51 Hall Probe Field Measurement, B = -0.001000 T 16:12:58 Move Stage, position = 0.220000 16:13:00 Stage Position Measurement, pos = 0.220000 m 16:13:01 Magnet Current, Imag = 149.9494 A Vtrans = 1.499494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:02 Hall Probe Field Measurement, B = -0.000800 T 16:13:09 Move Stage, position = 0.230000 16:13:11 Stage Position Measurement, pos = 0.230000 m 16:13:12 Magnet Current, Imag = 149.9547 A Vtrans = 1.499547 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:12 Hall Probe Field Measurement, B = -0.000700 T 16:13:19 Move Stage, position = 0.240000 16:13:21 Stage Position Measurement, pos = 0.240000 m 16:13:22 Magnet Current, Imag = 149.9479 A Vtrans = 1.499479 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:23 Hall Probe Field Measurement, B = -0.000600 T 16:13:30 Move Stage, position = 0.250000 16:13:31 Stage Position Measurement, pos = 0.250000 m 16:13:33 Magnet Current, Imag = 149.9510 A Vtrans = 1.499510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:33 Hall Probe Field Measurement, B = -0.000400 T 16:14:28 Move Stage, position = 0.000000 16:14:28 Magnet current ramping to 220.0000 A... 16:16:34 Move Stage, position = -0.250000 16:16:36 Stage Position Measurement, pos = -0.250000 m 16:16:37 Magnet Current, Imag = 219.9436 A Vtrans = 2.199436 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:38 Hall Probe Field Measurement, B = -0.000700 T 16:16:45 Move Stage, position = -0.240000 16:16:46 Stage Position Measurement, pos = -0.240000 m 16:16:48 Magnet Current, Imag = 219.9398 A Vtrans = 2.199398 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:48 Hall Probe Field Measurement, B = -0.001000 T 16:16:55 Move Stage, position = -0.230000 16:16:57 Stage Position Measurement, pos = -0.230000 m 16:16:58 Magnet Current, Imag = 219.9368 A Vtrans = 2.199368 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:58 Hall Probe Field Measurement, B = -0.001100 T 16:17:06 Move Stage, position = -0.220000 16:17:07 Stage Position Measurement, pos = -0.220000 m 16:17:08 Magnet Current, Imag = 219.9405 A Vtrans = 2.199405 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:09 Hall Probe Field Measurement, B = -0.001200 T 16:17:16 Move Stage, position = -0.210000 16:17:18 Stage Position Measurement, pos = -0.210000 m 16:17:19 Magnet Current, Imag = 219.9424 A Vtrans = 2.199424 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:20 Hall Probe Field Measurement, B = -0.001600 T 16:17:28 Move Stage, position = -0.200000 16:17:29 Stage Position Measurement, pos = -0.200000 m 16:17:30 Magnet Current, Imag = 219.9410 A Vtrans = 2.199410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:31 Hall Probe Field Measurement, B = -0.002000 T 16:17:38 Move Stage, position = -0.190000 16:17:40 Stage Position Measurement, pos = -0.190000 m 16:17:41 Magnet Current, Imag = 219.9413 A Vtrans = 2.199413 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:41 Hall Probe Field Measurement, B = -0.002600 T 16:17:48 Move Stage, position = -0.180000 16:17:50 Stage Position Measurement, pos = -0.180000 m 16:17:51 Magnet Current, Imag = 219.9406 A Vtrans = 2.199406 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:52 Hall Probe Field Measurement, B = -0.003500 T 16:17:59 Move Stage, position = -0.170000 16:18:01 Stage Position Measurement, pos = -0.170000 m 16:18:02 Magnet Current, Imag = 219.9418 A Vtrans = 2.199418 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:02 Hall Probe Field Measurement, B = -0.005000 T 16:18:09 Move Stage, position = -0.160000 16:18:11 Stage Position Measurement, pos = -0.160000 m 16:18:12 Magnet Current, Imag = 219.9409 A Vtrans = 2.199409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:13 Hall Probe Field Measurement, B = -0.007200 T 16:18:20 Move Stage, position = -0.150000 16:18:21 Stage Position Measurement, pos = -0.150000 m 16:18:23 Magnet Current, Imag = 219.9393 A Vtrans = 2.199393 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:23 Hall Probe Field Measurement, B = -0.011200 T 16:18:30 Move Stage, position = -0.140000 16:18:32 Stage Position Measurement, pos = -0.140000 m 16:18:33 Magnet Current, Imag = 219.9439 A Vtrans = 2.199439 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:34 Hall Probe Field Measurement, B = -0.018300 T 16:18:41 Move Stage, position = -0.130000 16:18:42 Stage Position Measurement, pos = -0.130000 m 16:18:44 Magnet Current, Imag = 219.9407 A Vtrans = 2.199407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:44 Hall Probe Field Measurement, B = -0.031100 T 16:18:51 Move Stage, position = -0.120000 16:18:53 Stage Position Measurement, pos = -0.120000 m 16:18:54 Magnet Current, Imag = 219.9412 A Vtrans = 2.199412 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:54 Hall Probe Field Measurement, B = -0.054200 T 16:19:02 Move Stage, position = -0.110000 16:19:03 Stage Position Measurement, pos = -0.110000 m 16:19:04 Magnet Current, Imag = 219.9459 A Vtrans = 2.199459 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:05 Hall Probe Field Measurement, B = -0.093000 T 16:19:12 Move Stage, position = -0.100000 16:19:14 Stage Position Measurement, pos = -0.100000 m 16:19:15 Magnet Current, Imag = 219.9373 A Vtrans = 2.199373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:15 Hall Probe Field Measurement, B = -0.146300 T 16:19:22 Move Stage, position = -0.090000 16:19:24 Stage Position Measurement, pos = -0.090000 m 16:19:25 Magnet Current, Imag = 219.9436 A Vtrans = 2.199436 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:26 Hall Probe Field Measurement, B = -0.204000 T 16:19:33 Move Stage, position = -0.080000 16:19:34 Stage Position Measurement, pos = -0.080000 m 16:19:36 Magnet Current, Imag = 219.9404 A Vtrans = 2.199404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:37 Hall Probe Field Measurement, B = -0.250100 T 16:19:45 Move Stage, position = -0.070000 16:19:46 Stage Position Measurement, pos = -0.070000 m 16:19:47 Magnet Current, Imag = 219.9451 A Vtrans = 2.199451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:48 Hall Probe Field Measurement, B = -0.281300 T 16:19:55 Move Stage, position = -0.060000 16:19:57 Stage Position Measurement, pos = -0.060000 m 16:19:58 Magnet Current, Imag = 219.9414 A Vtrans = 2.199414 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:58 Hall Probe Field Measurement, B = -0.300600 T 16:20:05 Move Stage, position = -0.050000 16:20:07 Stage Position Measurement, pos = -0.050000 m 16:20:08 Magnet Current, Imag = 219.9396 A Vtrans = 2.199396 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:09 Hall Probe Field Measurement, B = -0.311700 T 16:20:16 Move Stage, position = -0.040000 16:20:17 Stage Position Measurement, pos = -0.040000 m 16:20:19 Magnet Current, Imag = 219.9404 A Vtrans = 2.199404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:19 Hall Probe Field Measurement, B = -0.318100 T 16:20:26 Move Stage, position = -0.030000 16:20:28 Stage Position Measurement, pos = -0.030000 m 16:20:29 Magnet Current, Imag = 219.9399 A Vtrans = 2.199399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:30 Hall Probe Field Measurement, B = -0.322100 T 16:20:37 Move Stage, position = -0.020000 16:20:38 Stage Position Measurement, pos = -0.020000 m 16:20:40 Magnet Current, Imag = 219.9413 A Vtrans = 2.199413 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:40 Hall Probe Field Measurement, B = -0.324700 T 16:20:47 Move Stage, position = -0.010000 16:20:49 Stage Position Measurement, pos = -0.010000 m 16:20:50 Magnet Current, Imag = 219.9427 A Vtrans = 2.199427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:50 Hall Probe Field Measurement, B = -0.327100 T 16:20:58 Move Stage, position = 0.000000 16:20:59 Stage Position Measurement, pos = 0.000000 m 16:21:00 Magnet Current, Imag = 219.9408 A Vtrans = 2.199408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:01 Hall Probe Field Measurement, B = -0.329300 T 16:21:08 Move Stage, position = 0.010000 16:21:10 Stage Position Measurement, pos = 0.010000 m 16:21:11 Magnet Current, Imag = 219.9392 A Vtrans = 2.199392 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:11 Hall Probe Field Measurement, B = -0.331800 T 16:21:18 Move Stage, position = 0.020000 16:21:20 Stage Position Measurement, pos = 0.020000 m 16:21:21 Magnet Current, Imag = 219.9445 A Vtrans = 2.199445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:22 Hall Probe Field Measurement, B = -0.333000 T 16:21:29 Move Stage, position = 0.030000 16:21:30 Stage Position Measurement, pos = 0.030000 m 16:21:32 Magnet Current, Imag = 219.9394 A Vtrans = 2.199394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:32 Hall Probe Field Measurement, B = -0.330300 T 16:21:39 Move Stage, position = 0.040000 16:21:41 Stage Position Measurement, pos = 0.040000 m 16:21:42 Magnet Current, Imag = 219.9399 A Vtrans = 2.199399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:43 Hall Probe Field Measurement, B = -0.323200 T 16:21:50 Move Stage, position = 0.050000 16:21:51 Stage Position Measurement, pos = 0.050000 m 16:21:53 Magnet Current, Imag = 219.9478 A Vtrans = 2.199478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:53 Hall Probe Field Measurement, B = -0.312800 T 16:22:00 Move Stage, position = 0.060000 16:22:02 Stage Position Measurement, pos = 0.060000 m 16:22:03 Magnet Current, Imag = 219.9408 A Vtrans = 2.199408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:03 Hall Probe Field Measurement, B = -0.298800 T 16:22:11 Move Stage, position = 0.070000 16:22:12 Stage Position Measurement, pos = 0.070000 m 16:22:13 Magnet Current, Imag = 219.9395 A Vtrans = 2.199395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:14 Hall Probe Field Measurement, B = -0.276900 T 16:22:21 Move Stage, position = 0.080000 16:22:23 Stage Position Measurement, pos = 0.080000 m 16:22:24 Magnet Current, Imag = 219.9394 A Vtrans = 2.199394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:24 Hall Probe Field Measurement, B = -0.244200 T 16:22:31 Move Stage, position = 0.090000 16:22:33 Stage Position Measurement, pos = 0.090000 m 16:22:34 Magnet Current, Imag = 219.9412 A Vtrans = 2.199412 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:35 Hall Probe Field Measurement, B = -0.196800 T 16:22:42 Move Stage, position = 0.100000 16:22:43 Stage Position Measurement, pos = 0.100000 m 16:22:45 Magnet Current, Imag = 219.9443 A Vtrans = 2.199443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:45 Hall Probe Field Measurement, B = -0.139500 T 16:22:52 Move Stage, position = 0.110000 16:22:54 Stage Position Measurement, pos = 0.110000 m 16:22:55 Magnet Current, Imag = 219.9385 A Vtrans = 2.199385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:56 Hall Probe Field Measurement, B = -0.087300 T 16:23:03 Move Stage, position = 0.120000 16:23:04 Stage Position Measurement, pos = 0.120000 m 16:23:05 Magnet Current, Imag = 219.9437 A Vtrans = 2.199437 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:06 Hall Probe Field Measurement, B = -0.050700 T 16:23:13 Move Stage, position = 0.130000 16:23:15 Stage Position Measurement, pos = 0.130000 m 16:23:16 Magnet Current, Imag = 219.9389 A Vtrans = 2.199389 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:16 Hall Probe Field Measurement, B = -0.029100 T 16:23:23 Move Stage, position = 0.140000 16:23:25 Stage Position Measurement, pos = 0.140000 m 16:23:26 Magnet Current, Imag = 219.9372 A Vtrans = 2.199372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:27 Hall Probe Field Measurement, B = -0.017100 T 16:23:34 Move Stage, position = 0.150000 16:23:36 Stage Position Measurement, pos = 0.150000 m 16:23:37 Magnet Current, Imag = 219.9400 A Vtrans = 2.199400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:37 Hall Probe Field Measurement, B = -0.010500 T 16:23:44 Move Stage, position = 0.160000 16:23:46 Stage Position Measurement, pos = 0.160000 m 16:23:47 Magnet Current, Imag = 219.9410 A Vtrans = 2.199410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:48 Hall Probe Field Measurement, B = -0.006800 T 16:23:55 Move Stage, position = 0.170000 16:23:56 Stage Position Measurement, pos = 0.170000 m 16:23:58 Magnet Current, Imag = 219.9402 A Vtrans = 2.199402 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:58 Hall Probe Field Measurement, B = -0.004700 T 16:24:05 Move Stage, position = 0.180000 16:24:07 Stage Position Measurement, pos = 0.180000 m 16:24:08 Magnet Current, Imag = 219.9381 A Vtrans = 2.199381 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:08 Hall Probe Field Measurement, B = -0.003300 T 16:24:16 Move Stage, position = 0.190000 16:24:17 Stage Position Measurement, pos = 0.190000 m 16:24:18 Magnet Current, Imag = 219.9391 A Vtrans = 2.199391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:19 Hall Probe Field Measurement, B = -0.002500 T 16:24:26 Move Stage, position = 0.200000 16:24:28 Stage Position Measurement, pos = 0.200000 m 16:24:29 Magnet Current, Imag = 219.9370 A Vtrans = 2.199370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:29 Hall Probe Field Measurement, B = -0.002000 T 16:24:36 Move Stage, position = 0.210000 16:24:38 Stage Position Measurement, pos = 0.210000 m 16:24:39 Magnet Current, Imag = 219.9417 A Vtrans = 2.199417 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:40 Hall Probe Field Measurement, B = -0.001500 T 16:24:47 Move Stage, position = 0.220000 16:24:48 Stage Position Measurement, pos = 0.220000 m 16:24:50 Magnet Current, Imag = 219.9406 A Vtrans = 2.199406 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:50 Hall Probe Field Measurement, B = -0.001200 T 16:24:57 Move Stage, position = 0.230000 16:24:59 Stage Position Measurement, pos = 0.230000 m 16:25:00 Magnet Current, Imag = 219.9401 A Vtrans = 2.199401 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:01 Hall Probe Field Measurement, B = -0.001100 T 16:25:08 Move Stage, position = 0.240000 16:25:09 Stage Position Measurement, pos = 0.240000 m 16:25:10 Magnet Current, Imag = 219.9433 A Vtrans = 2.199433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:11 Hall Probe Field Measurement, B = -0.001000 T 16:25:18 Move Stage, position = 0.250000 16:25:20 Stage Position Measurement, pos = 0.250000 m 16:25:21 Magnet Current, Imag = 219.9413 A Vtrans = 2.199413 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:21 Hall Probe Field Measurement, B = -0.000800 T 16:26:17 Move Stage, position = 0.000000 16:26:17 Magnet current ramping to 0.0000 A...