SLAC Magnetic Measurements Date: 09-23-2008 Time: 11:54:43 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 09-23-2008 Time: 11:39:19 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-40 DATASET Number: 1 Tuning Stage: Rough Tuning Run Number: 51 Measurement Type: Z Scans Operator: aw Comment: f.p. 0.370833, x=0.026436 y=0.00023504. Replace x-shim. at 43 by 2-screw 0.28 in one. Measurement Device x: Measurement Device y: SENIS_24-06 Data File: s:\magdata\LCLS\Undulator\L143-112000-40\DATASET0001\Rough Tuning\Z Scans\Run 051\bscanz.dat Temperature (C) L143-112000-40:--> top_start 20.06 --> top_mid 20.07 --> top_end 19.95 --> bot 20.05 --> granite 19.98 --> Air 19.96 Axes position (m) X:0.026436 Y:0.000234 Initial Hall Probe Zero Measurements: Vx_0i = -0.000340 V Vy_0i = -0.000328 V Final Hall Probe Zero Measurements: Vx_0f = -0.000332 V Vy_0f = -0.000320 V Offset Correction Voff = offset+index*increment index = 0,1...19850 Vx:offset = -0.000340 V, increment = 4.397E-10 V Vy:offset = -0.000328 V, increment = 4.430E-10 V Hall Probe Calibration File: Y: C:\CVI\current_calib\SENIS_24-06\SENIS_24-06_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-40\DATASET0001\Rough Tuning\Z Scans\Run 051\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = 0.000015 T Correction, By additive constant = 0.000000 T Correction Bxy additive file = S:\Magdata\Earth Field Correction\earth_field_corr.dat Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26658.880000 Electron energy = 13.622663 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.492672 Nominal radiation wavelength = 1.498400e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = 0.000015 T CORR_BY_ADD = 0.000000 T CORR_BX_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat CORR_BY_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.273802 T, RMS = 0.007390 T Peak Field Spacing: Ave = 0.015000 m, RMS = 0.000023 m Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000046 m Average Undulator Period = 0.029999 m Hall Probe Overall Field Integrals: Int Bx dz = 1.8029e-006 Tm Int Int Bx dz dz = 1.3108e-005 Tm^2 Int By dz = 1.9235e-005 Tm Int Int By dz dz = 2.0338e-004 Tm^2 Trajectory Exit Information: X at exit = 4.4759e-006 m X slope at exit = 4.2331e-007 Y at exit = -2.8847e-007 m Y slope at exit = -3.9675e-008 Calculated Undulator Parameters: Keff = 3.493161 Beff = 1.247056 T Lambda_rad = 1.498728e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.032500 C Measured Keff = 3.493161 Calculated Keff at 20 C = 3.493217 Relative Change (Keff_20C - Keff) / Keff = 0.000016 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99587e-009 Undulator Period = 0.029999 m Radiation Wavelength = 1.49873e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, Phase error RMS = 6.265201 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49840e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 2.311690 deg, RMS = 4.655870 deg Center: Phase Error Of All Poles In Undulator Center: Ave = 0.587701 deg, RMS = 6.790715 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = -1.222341 deg, RMS = 4.239138 deg Cell: Phase Change Of Cell = 40697.407 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 17.407 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.032500 C Measured Phase Change Of Cell = 40697.407 deg Calculated Phase Change Of Cell At 20 C = 40698.544 deg Phase Change Due To Temperature (Phase_20C - Phase) = 1.136 deg