SLAC Magnetic Measurements Date: 09-21-2009 Time: 17:52:56 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 09-08-2009 Time: 16:21:54 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-27 DATASET Number: 1 Tuning Stage: Fine Tuning Run Number: 4 Measurement Type: Z Scans Operator: YL Comment: final Session first run: 4 Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-27\DATASET0001\Fine Tuning\Z Scans\Run 004\bscanz.dat Temperature (C) L143-112000-27:--> T5 19.03 --> T2 19.06 --> T1 19.09 --> T3 19.05 --> Air 19.13 --> T4 19.04 Axes position (m) X:0.024970 Y:0.000346 Initial Hall Probe Zero Measurements: Vx_0i = 0.001439 V Vy_0i = -0.001670 V Final Hall Probe Zero Measurements: Vx_0f = 0.001394 V Vy_0f = -0.001624 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.001439 V, increment = -2.116E-09 V Vy:offset = -0.001670 V, increment = 2.184E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = C:\Magdata\SN27 Temperature Test\dKdx_19p0C_2\ Input file name = x-01000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000024 T Correction, By additive constant = 0.000001 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26635.500000 Electron energy = 13.610716 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.487608 Nominal radiation wavelength = 1.497295e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000024 T CORR_BY_ADD = 0.000001 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.270874 T, RMS = 0.006003 T Peak Field Spacing: Ave = 0.015000 m, RMS = 0.000022 m Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000043 m Average Undulator Period = 0.030000 m Hall Probe Overall Field Integrals: Int Bx dz = -1.6515e-005 Tm Int Int Bx dz dz = 2.8613e-005 Tm^2 Int By dz = 3.4481e-005 Tm Int Int By dz dz = 8.6453e-005 Tm^2 Trajectory Exit Information: X at exit = 1.9042e-006 m X slope at exit = 7.5948e-007 Y at exit = -6.3024e-007 m Y slope at exit = 3.6377e-007 Calculated Undulator Parameters: Keff = 3.484945 Beff = 1.244088 T Lambda_rad = 1.495341e-010 m Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.98444e-009 Undulator Period = 0.030000 m Radiation Wavelength = 1.49534e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 3.400478 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49729e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = -2.044276 deg, RMS = 3.046921 deg Center: Phase Error Of All Poles In Undulator Center: Ave = -29.219573 deg, RMS = 15.652680 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = -2.898279 deg, RMS = 5.335951 deg Cell: Phase Change Of Cell = 40622.761 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = -57.239 deg