SLAC Magnetic Measurements Date: 09-12-2007 Time: 10:17:46 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 09-12-2007 Time: 10:05:54 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-25 DATASET Number: 1 Tuning Stage: Fine Tuning Run Number: 8 Measurement Type: Z Scans Operator: YL Comment: find y at min K; before final scans Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-25\DATASET0001\Fine Tuning\Z Scans\Run 008\bscanz.dat Temperature (C) L143-112000-25:--> top_end 19.90 --> top_mid 19.93 --> top_start 19.96 --> bottom 19.92 --> Air 19.93 --> Granite 19.91 Axes position (m) X:0.029853 Y:0.000158 Initial Hall Probe Zero Measurements: Vx_0i = 0.001485 V Vy_0i = -0.000674 V Final Hall Probe Zero Measurements: Vx_0f = 0.001503 V Vy_0f = -0.000668 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.001485 V, increment = 8.540E-10 V Vy:offset = -0.000674 V, increment = 2.640E-10 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-25\DATASET0001\Fine Tuning\Z Scans\Run 008\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000012 T Correction, By additive constant = -0.000014 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26673.630000 Electron energy = 13.630200 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.495869 Nominal radiation wavelength = 1.499099e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000012 T CORR_BY_ADD = -0.000014 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.275115 T, RMS = 0.006128 T Peak Field Spacing: Ave = 0.014999 m, RMS = 0.000023 m Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000034 m Average Undulator Period = 0.029999 m Hall Probe Overall Field Integrals: Int Bx dz = -3.3198e-005 Tm Int Int Bx dz dz = 3.0266e-005 Tm^2 Int By dz = 4.2945e-006 Tm Int Int By dz dz = -2.3527e-005 Tm^2 Trajectory Exit Information: X at exit = -5.1747e-007 m X slope at exit = 9.4457e-008 Y at exit = -6.6570e-007 m Y slope at exit = 7.3018e-007 Calculated Undulator Parameters: Keff = 3.495838 Beff = 1.248035 T Lambda_rad = 1.499015e-010 m Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99692e-009 Undulator Period = 0.029999 m Radiation Wavelength = 1.49901e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = 0.000000 deg, RMS = 3.717494 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49910e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Phase Error Relative To Nominal Radiation Wave In Undulator Center: Ave = 1.872550 deg, RMS = 3.863549 deg Entrance: Phase Change From Cell Boundary To Pole After End Poles = 814.200 deg Nominal Phase Change From Cell Boundary To Pole After End Poles = 810.000 deg Phase Error At Pole After End Poles = 4.200 deg Center: Phase Change In Center (Center Poles Between End Poles) = 39044.325 deg Nominal Phase Change In Center = 39060.000 deg Phase Error In Center Poles Between End Poles = -15.675 deg Exit: Phase Change From Pole Before End Poles To Cell Boundary = 821.594 deg Nominal Phase Change From Pole Before End Poles To Cell Boundary = 810.000 deg Phase Error From Pole Before End Poles To Cell Boundary = 11.594 deg Cell: Phase Change Of Cell = 40680.119 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 0.119 deg