SLAC Magnetic Measurements
Date: 02-22-2007
Time: 14:54:17
 
Planar Insertion Device Analysis
--------------------------------

Data File Header:
SLAC Magnetic Measurements
Date: 02-20-2007
Time: 17:57:33
Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-17
DATASET Number: 1
Tuning Stage: Rough Tuning
Run Number: 22
Measurement Type: Z Scans
Operator: AW
Comment: x=0.028151 y=0.000268 new center 
Measurement Device x: 
Measurement Device y: SENIS_24-06
Data File: s:\magdata\LCLS\Undulator\L143-112000-17\DATASET0001\Rough Tuning\Z Scans\Run 022\bscanz_dat.001
Temperature (C)
L143-112000-17:--> start 20.16 --> mid 20.17 --> end 20.07 --> bot 20.14 --> gra 20.10 --> air 20.05 
Axes position (m) X:0.028151 Y:0.000268
Initial Hall Probe Zero Measurements:
Vx_0i = -0.000320 V
Vy_0i = -0.000323 V
Final Hall Probe Zero Measurements:
Vx_0f = -0.000376 V
Vy_0f = -0.000346 V
Offset Correction Voff = offset+index*increment
index = 0,1...19850
Vx:offset = -0.000320 V, increment = -2.814E-09 V
Vy:offset = -0.000323 V, increment = -1.182E-09 V
Hall Probe Calibration File:
Y: C:\CVI\current_calib\SENIS_24-06\SENIS_24-06_y.ini
X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
Reference Magnet Measurements:
Bx_ref = 0.0000xx (T)
By_ref = 0.0000xx (T)
Magnetic Field Measurements vs Z

Analysis Parameters:
Input file directory = S:\MagData\LCLS\Undulator\L143-112000-17\DATASET0001\Rough Tuning\Z Scans\Run 022\
Input file name = bscanz_dat.001
Input file type = ZVXYBXYH
Correction required = 1
Correction file = S:\Magdata\Earth Field Correction\earth_field_corr.dat
Correction file type = CORR_ZBXY
Electron gamma = 26692.700000
Electron energy = 13.639949 Gev
Nominal undulator period = 0.030000 m
Nominal K value = 3.500000
Nominal radiation wavelength = 1.500000e-010 m
Number of undulator poles = 226
Number of end poles (used in analysis) = 4
Cell length = 3.656000 m

Field Correction:
The file
S:\Magdata\Earth Field Correction\earth_field_corr.dat
was used to correct Bx and By.

Peak And Zero Field Summary:
Number of Poles = 226
Number of End Poles (excluded in statistics) = 4
Peak Fields: Ave = 1.276270 T, RMS = 0.003600 T
Peak Field Spacing: Ave = 0.015001 m, RMS = 0.000024 m
Zero Field Spacing: Ave = 0.015001 m, RMS = 0.000032 m
Average Undulator Period = 0.030001 m

Hall Probe Overall Field Integrals:
Int Bx dz =   3.5043e-004 Tm
Int Int Bx dz dz =   5.9240e-004 Tm^2
Int By dz =   4.4066e-005 Tm
Int Int By dz dz =   4.2971e-004 Tm^2

Trajectory Exit Information:
X at exit =   9.4446e-006 m
X slope at exit =   9.6852e-007
Y at exit =  -1.3020e-005 m
Y slope at exit =  -7.7021e-006

Calculated Undulator Parameters:
Keff = 3.503277
Beff = 1.250617 T
Lambda_rad = 1.502443e-010 m

Phase Fluctuations:
Slippage vs Z At Peaks Fitted Slope =   5.00805e-009
Undulator Period = 0.030001 m
Radiation Wavelength =   1.50244e-010 m
Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 11.990573 deg

Phase Relative To Nominal Radiation Wave:
Nominal Radiation Wavelength =   1.50000e-010 m
Cell Length = 3.656000 m
Number Of End Poles = 4
Phase Change Into Undulator (To Pole After End Poles) =     852.855 deg, mod_360 =     132.855 deg
Phase Change Through Undulator (Poles Between End Poles) =   39114.293 deg, mod_360 =     234.293 deg
Phase Change Out Of Undulator (To Pole Before End Poles) =     853.527 deg, mod_360 =     133.527 deg
Phase Change Of Cell =   40820.676 deg
Nominal Phase Change Of Cell =   40680.000 deg
Phase Error Of Cell =     140.676 deg