SLAC Magnetic Measurements
Date: 12-16-2015
Time: 12:12:31

Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-13
DATASET Number: 52
Tuning Stage: Fine Tuning
Run Number: 4
Measurement Type: Align X Scan
Operator: YL
Comment: alignment 
 Device:HP3458 , integration time = 0.060000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
12:12:50  Stage Zeroed
12:12:50 Move node 0:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:12:50 Move node 1:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:12:50 Move node 2:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:12:50 Move node 3:  Move Device = NONE, Read Device = NONE
*****************************************************************
------------------> get_data <----------------------
12:12:50 : humidity :  22.27
------------------> get_data <----------------------
12:12:50 : pressure : 1011.07
------------------> get_data <----------------------
12:12:50 : ambient : --> Ambient 19.84 
------------------> get_data <----------------------
12:12:50 : L143-112000-13 : --> T1 19.90 --> T2 19.93 --> T3 19.89 --> T4 19.91 --> T5 20.02 --> T(C) 19.97 --> RefM_2 20.02 

BSCANX: :  --== BscanX started ==--
 	 at 12-16-2015 12:12:54	 
Initial first pole position = 0.855957	 
Ycenter = 0.000000
BSCANX: : Calibration is up to date.
BSCANX: : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BSCANX: : CALIBRATION PROBE:	 poly_calib

BSCANX: : Zero field Y at start-> voltage:-0.003454	field: -0.000692T
BSCANX: : Zero field X at start-> voltage:0.000000	field: 0.000000T
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 5301
scans number = 0, threshold = 5300, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 45, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
12:13:05  Move:node 1 absolute position = 0.000400 m
12:13:10  Move:node 2 absolute position = 0.200000 m

Position (counts) fixed:1, secondary:1
12:13:21  Move:node 2 position incremented by = 0.855956 m

Position (counts) fixed:1, secondary:1
12:13:34  Move:node 2 position incremented by = 0.855956 m

Position (counts) fixed:1, secondary:1
12:13:47  Move:node 2 position incremented by = 0.855956 m