SLAC Magnetic Measurements Date: 01-31-2008 Time: 13:18:14 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 01-31-2008 Time: 13:09:23 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-10 DATASET Number: 1 Tuning Stage: Fine Tuning Run Number: 7 Measurement Type: Z Scans Operator: YL Comment: find Y at min K; before final scans Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-10\DATASET0001\Fine Tuning\Z Scans\Run 007\bscanz.dat Temperature (C) L143-112000-10:--> top_end 19.91 --> top_mid 19.93 --> top_start 19.95 --> bottom 19.93 --> Air 20.03 --> Granite 19.91 Axes position (m) X:0.030310 Y:0.000465 Initial Hall Probe Zero Measurements: Vx_0i = 0.001659 V Vy_0i = -0.000879 V Final Hall Probe Zero Measurements: Vx_0f = 0.001639 V Vy_0f = -0.000871 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.001659 V, increment = -9.361E-10 V Vy:offset = -0.000879 V, increment = 3.538E-10 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-10\DATASET0001\Fine Tuning\Z Scans\Run 007\ Input file name = x+00000_y+100_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000004 T Correction, By additive constant = 0.000006 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26671.590000 Electron energy = 13.629158 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.495426 Nominal radiation wavelength = 1.499001e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000004 T CORR_BY_ADD = 0.000006 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.274926 T, RMS = 0.006825 T Peak Field Spacing: Ave = 0.015001 m, RMS = 0.000024 m Zero Field Spacing: Ave = 0.015001 m, RMS = 0.000033 m Average Undulator Period = 0.030002 m Hall Probe Overall Field Integrals: Int Bx dz = -1.3799e-004 Tm Int Int Bx dz dz = -2.9000e-004 Tm^2 Int By dz = 7.4183e-006 Tm Int Int By dz dz = -1.3677e-005 Tm^2 Trajectory Exit Information: X at exit = -3.0084e-007 m X slope at exit = 1.6318e-007 Y at exit = 6.3789e-006 m Y slope at exit = 3.0353e-006 Calculated Undulator Parameters: Keff = 3.496809 Beff = 1.248268 T Lambda_rad = 1.500098e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.930000 C Measured Keff = 3.496809 Calculated Keff at 20 C = 3.496687 Relative Change (Keff_20C - Keff) / Keff = -0.000035 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 5.00007e-009 Undulator Period = 0.030002 m Radiation Wavelength = 1.50010e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = 0.000000 deg, RMS = 4.014975 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49900e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 1.751725 deg, RMS = 4.922593 deg Center: Phase Error Of All Poles In Undulator Center: Ave = 7.667556 deg, RMS = 9.112422 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 4.170055 deg, RMS = 5.020533 deg Cell: Phase Change Of Cell = 40704.107 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 24.107 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.930000 C Measured Phase Change Of Cell = 40704.107 deg Calculated Phase Change Of Cell At 20 C = 40701.658 deg Phase Change Due To Temperature (Phase_20C - Phase) = -2.449 deg