SLAC Magnetic Measurements Date: 10-02-2013 Time: 09:43:29 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 10-02-2013 Time: 09:34:22 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-07 DATASET Number: 3 Tuning Stage: Fine Tuning Run Number: 6 Measurement Type: Z Scans Operator: YL Comment: find Y at min K; before final Session first run: 6 Measurement Device x: Measurement Device y: SENTRON_441 Data File: c:\magdata\LCLS\Undulator\L143-112000-07\DATASET0003\Fine Tuning\Z Scans\Run 006\bscanz.dat Temperature (C) L143-112000-07:--> T1 20.01 --> T2 19.99 --> T5 19.95 --> T3 20.00 --> Air 19.98 --> T4 19.96 Axes position (m) X:0.030023 Y:0.000127 Initial Hall Probe Zero Measurements: Vx_0i = 0.000904 V Vy_0i = -0.003307 V Final Hall Probe Zero Measurements: Vx_0f = 0.000931 V Vy_0f = -0.003341 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.000904 V, increment = 1.241E-09 V Vy:offset = -0.003307 V, increment = -1.593E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = c:\Magdata\LCLS\Undulator\L143-112000-07\DATASET0003\Fine Tuning\Z Scans\Run 006\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000015 T Correction, By additive constant = -0.000003 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26654.560000 Electron energy = 13.620455 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.491738 Nominal radiation wavelength = 1.498197e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000015 T CORR_BY_ADD = -0.000003 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.274174 T, RMS = 0.007184 T Peak Field Spacing: Ave = 0.015001 m, RMS = 0.000024 m Zero Field Spacing: Ave = 0.015001 m, RMS = 0.000035 m Average Undulator Period = 0.030001 m Hall Probe Overall Field Integrals: Int Bx dz = 6.6113e-006 Tm Int Int Bx dz dz = -2.2662e-005 Tm^2 Int By dz = 7.1199e-006 Tm Int Int By dz dz = -1.8271e-005 Tm^2 Trajectory Exit Information: X at exit = -4.0216e-007 m X slope at exit = 1.5671e-007 Y at exit = 4.9880e-007 m Y slope at exit = -1.4552e-007 Calculated Undulator Parameters: Keff = 3.491720 Beff = 1.246453 T Lambda_rad = 1.498258e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.987500 C Measured Keff = 3.491720 Calculated Keff at 20 C = 3.491701 Relative Change (Keff_20C - Keff) / Keff = -0.000005 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99395e-009 Undulator Period = 0.030001 m Radiation Wavelength = 1.49826e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = 0.000000 deg, Phase error RMS = 3.183008 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49820e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 0.473585 deg, RMS = 6.153526 deg Center: Phase Error Of All Poles In Undulator Center: Ave = -2.253506 deg, RMS = 3.337259 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 2.834775 deg, RMS = 5.507542 deg Cell: Phase Change Of Cell = 40679.936 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = -0.064 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.987500 C Measured Phase Change Of Cell = 40679.936 deg Calculated Phase Change Of Cell At 20 C = 40679.499 deg Phase Change Due To Temperature (Phase_20C - Phase) = -0.437 deg