SLAC Magnetic Measurements
Date: 01-17-2007
Time: 14:40:46
 
Planar Insertion Device Analysis
--------------------------------

Data File Header:
SLAC Magnetic Measurements
Date: 01-17-2007
Time: 14:30:38
Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-03
RMA Number: 1
Tuning Stage: Rough Tuning
Run Number: 70
Measurement Type: Z Scans
Operator: aww
Comment: After gap  shim for phase, same x,y as before.
Measurement Device x: 
Measurement Device y: SENIS_24-06
Data File: c:\magdata\LCLS\Undulator\L143-112000-03\RMA0001\Rough Tuning\Z Scans\Run 070\bscanz_dat.001
Initial Hall Probe Zero Measurements:
Vx_0i = -0.000382 V
Vy_0i = -0.000504 V
Final Hall Probe Zero Measurements:
Vx_0f = -0.000312 V
Vy_0f = -0.000469 V
Offset Correction Voff = offset+index*increment
index = 0,1...19850
Vx:offset = -0.000382 V, increment = 3.555E-09 V
Vy:offset = -0.000504 V, increment = 1.773E-09 V
Hall Probe Calibration File:
Y: C:\CVI\current_calib\SENIS_24-06\SENIS_24-06_y.ini
X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
Reference Magnet Measurements:
Bx_ref = 0.0000xx (T)
By_ref = 0.0000xx (T)
Magnetic Field Measurements vs Z

Analysis Parameters:
Input file directory = C:\magdata\Lcls\Undulator\L143-112000-03\RMA0001\Rough Tuning\Z Scans\Run 070\
Input file name = bscanz_dat.001
Input file type = SLAC_VXVYBXBYVSZ
Correction required = 1
Correction file = c:\Insertion Device Analysis\Earth Field Correction\earth_field_corr.dat
Correction file type = CORR_BXBYVSZ
Electron gamma = 26652.520000
Electron energy = 13.620925 Gev
Nominal undulator period = 0.030000 m
Nominal K value = 3.491296
Nominal radiation wavelength = 1.500000e-010 m
Number of undulator poles = 226
Number of end poles (used in analysis) = 4
Cell length = 3.656000 m

Field Correction:
The file
c:\Insertion Device Analysis\Earth Field Correction\earth_field_corr.dat
was used to correct Bx and By.

Peak And Zero Field Summary:
Number of Poles = 226
Number of End Poles (excluded in statistics) = 4
Peak Fields: Ave = 1.274895 T, RMS = 0.003539 T
Peak Field Spacing: Ave = 0.015000 m, RMS = 0.000024 m
Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000036 m
Average Undulator Period = 0.029999 m

Hall Probe Overall Field Integrals:
Int Bx dz =   1.1022e-005 Tm
Int Int Bx dz dz =   6.5808e-005 Tm^2
Int By dz =  -1.8443e-005 Tm
Int Int By dz dz =  -2.9743e-005 Tm^2

Trajectory Exit Information:
X at exit =  -6.5471e-007 m
X slope at exit =  -4.0596e-007
Y at exit =  -1.4486e-006 m
Y slope at exit =  -2.4262e-007

Calculated Undulator Parameters:
Keff = 3.491677
Beff = 1.246523 T
Lambda_rad = 1.498353e-010 m

Phase Fluctuations:
Slippage vs Z At Peaks Fitted Slope =   4.99460e-009
Undulator Period = 0.029999 m
Radiation Wavelength =   1.49835e-010 m
Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 4.059446 deg

Phase Relative To Nominal Radiation Wave:
Nominal Radiation Wavelength =   1.50000e-010 m
Cell Length = 3.656000 m
Number Of End Poles = 4
Phase Change Into Undulator (To Pole After End Poles) =     853.472 deg, mod_360 =     133.472 deg
Phase Change Through Undulator (Poles Between End Poles) =   39017.822 deg, mod_360 =     137.822 deg
Phase Change Out Of Undulator (To Pole Before End Poles) =     847.675 deg, mod_360 =     127.675 deg
Phase Change Of Cell =   40718.970 deg, mod_360 =      38.970 deg