SLAC Magnetic Measurements
Date: 12-15-2006
Time: 15:26:36
 
Planar Insertion Device Analysis
--------------------------------

Data File Header:
SLAC Magnetic Measurements
Date: 12-15-2006
Time: 14:58:13
Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-03
RMA Number: 1
Tuning Stage: Rough Tuning
Run Number: 23
Measurement Type: Z Scans
Operator: aww
Comment: y-shim (SLAC-design) at15, and 78, plus small shims at 80, 82, 84.
Measurement Device x: 
Measurement Device y: SENTRON_441
Data File: c:\magdata\LCLS\Undulator\L143-112000-03\RMA0001\Rough Tuning\Z Scans\Run 023\bscanz_dat.001
Initial Hall Probe Zero Measurements:
Vx_0i = 0.001053 V
Vy_0i = -0.001651 V
Final Hall Probe Zero Measurements:
Vx_0f = 0.001085 V
Vy_0f = -0.001610 V
Offset Correction Voff = offset+index*increment
index = 0,1...19850
Vx:offset = 0.001053 V, increment = 1.629E-09 V
Vy:offset = -0.001651 V, increment = 2.069E-09 V
Hall Probe Calibration File:
Y: c:\cvi\current_calib\Sentron_441\Sentron_441_y.ini
X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
Reference Magnet Measurements:
Bx_ref = 0.0000xx (T)
By_ref = 0.0000xx (T)
Magnetic Field Measurements vs Z

Analysis Parameters:
Input file directory = C:\magdata\Lcls\Undulator\L143-112000-03\RMA0001\Rough Tuning\Z Scans\Run 023\
Input file name = bscanz_dat.001
Input file type = SLAC_VXVYBXBYVSZ
Correction required = 1
Correction file = c:\Insertion Device Analysis\Earth Field Correction\earth_field_corr.dat
Correction file type = CORR_BXBYVSZ
Electron gamma = 26692.700000
Electron energy = 13.641459 Gev
Nominal undulator period = 0.030000 m
Nominal K value = 3.500000
Nominal radiation wavelength = 1.500000e-010 m
Number of undulator poles = 226
Number of end poles (used in analysis) = 4
Cell length = 3.656000 m

Field Correction:
The file
c:\Insertion Device Analysis\Earth Field Correction\earth_field_corr.dat
was used to correct Bx and By.

Peak And Zero Field Summary:
Number of Poles = 226
Number of End Poles (excluded in statistics) = 4
Peak Fields: Ave = 1.273340 T, RMS = 0.003989 T
Peak Field Spacing: Ave = 0.014999 m, RMS = 0.000024 m
Zero Field Spacing: Ave = 0.014999 m, RMS = 0.000036 m
Average Undulator Period = 0.029999 m

Hall Probe Overall Field Integrals:
Int Bx dz =   2.0526e-005 Tm
Int Int Bx dz dz =   2.5140e-004 Tm^2
Int By dz =  -8.5686e-006 Tm
Int Int By dz dz =  -1.5658e-005 Tm^2

Trajectory Exit Information:
X at exit =  -3.4414e-007 m
X slope at exit =  -1.8833e-007
Y at exit =  -5.5255e-006 m
Y slope at exit =  -4.5114e-007

Calculated Undulator Parameters:
Keff = 3.488451
Beff = 1.245401 T
Lambda_rad = 1.491441e-010 m

Phase Fluctuations:
Slippage vs Z At Peaks Fitted Slope =   4.97168e-009
Undulator Period = 0.029999 m
Radiation Wavelength =   1.49144e-010 m
Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 15.621176 deg

Phase Relative To Nominal Radiation Wave:
Nominal Radiation Wavelength =   1.50000e-010 m
Cell Length = 3.656000 m
Number Of End Poles = 4
Phase Change Into Undulator (To Pole After End Poles) =     850.326 deg, mod_360 =     130.326 deg
Phase Change Through Undulator (Poles Between End Poles) =   38820.906 deg, mod_360 =     300.906 deg
Phase Change Out Of Undulator (To Pole Before End Poles) =     844.198 deg, mod_360 =     124.198 deg
Phase Change Of Cell =   40515.431 deg, mod_360 =     195.431 deg