SLAC Magnetic Measurements
Date: 02-01-2010
Time: 12:09:43

Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: ECKO7-55
DATASET Number: 1
Tuning Stage: Fine Tuning
Run Number: 3
Measurement Type: Align X Scan
Operator: YL
Comment: scan at magnet #10; y-trajectory shim
 Device:HP3458 , integration time = 0.060000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:HP3458 , integration time = 0.060000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
12:09:53  Stage Zeroed
12:09:53 Move node 0:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:09:54 Move node 1:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:09:54 Move node 2:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
12:09:54 Move node 3:  Move Device = NONE, Read Device = NONE
*****************************************************************
------------------> get_data <----------------------
12:09:57 : humidity :  37.95
------------------> get_data <----------------------
12:09:57 : pressure : 1001.29
------------------> get_data <----------------------
12:09:57 : ambient : --> Ambient 19.94 --> KGranite 20.01 --> KRefM 20.01 
------------------> get_data <----------------------
12:09:57 : ECKO7-55 : --> T5 20.16 --> T2 20.16 --> T1 20.12 --> T3 20.16 --> Air 20.10 --> T4 20.16 

BscanX :  --== BscanX started ==--
 	 at 02-01-2010 12:10:06	 
Initial first pole position = 2.587000	 
Ycenter = 0.000213
BscanX : Calibration is up to date.
BscanX : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BscanX : CALIBRATION PROBE:	 poly_calib
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 6001
scans number = 0, threshold = 6000, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 0, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
12:10:09  Move:node 1 absolute position = 0.000400 m
12:10:14  Move:node 2 absolute position = 0.100000 m

Position (counts) fixed:600, secondary:37095
12:10:26  Move:node 1 position incremented by = -0.000086 m

Position (counts) fixed:428, secondary:37095
12:10:35  Move:node 2 position incremented by = 2.549905 m
	 
12:11:16  Move:node 0 absolute position = 0.067000 m
12:11:37  Stage Position Measurement, pos = 0.060019 m
12:11:37  Move:node 0 absolute position = 0.000000 m

VSCAN3: : Time Stamps 0.000000 0.000000 110.925000 132.347000 0.000000 0.000000	 
12:11:59  Move:node 2 absolute position = 0.000000 m
12:12:18  Move:node 1 absolute position = 0.000000 m

-->>12:12:22  VSCAN3:SCAN : 1
start_pos = 0.000000 (m), dist_move = 0.067000 (m), num_samp = 6001, 
 averaging number = 3

Primary axis: 1
Use indexes for travel range:0
Measuring length:0.060000

Secondary axis:3
Was active:1
Accuracy:0.000020
Start position:2.587000
Step size:0.027500
Number of steps:0

Fixed axis:2
Was active:1
Accuracy:0.000001
Position:0.000213

VSCAN3: Indices position error ->  0

VSCAN3: Back jumps number -> 99
VSCAN3: Triggers position error (counts)-> 40

VSCAN3: Fixed position -> 0.0002140
VSCAN3: Fixed position error -> 0.000000
VSCAN3: Fixed Idx position error -> 0.000000


VSCAN3: Secondary position -> 2.5869980
VSCAN3: Secondary position error -> 1.000000
VSCAN3: Secondary Idx position error -> 1.000000


BscanX : Pole number = 1.000000
BscanX : Pole Z-position = 2.587000 m
BscanX : Pole X-center = 0.030724 m
BscanX : Pole field = -0.388827 T
BscanX : Ready for new scan

BscanX : Zero field Y at stop-> voltage:-0.001865	field: -0.000374T
BscanX : Zero field X at stop-> voltage:0.001506	field: 0.000301T
BscanX :  --== BscanX started ==--
 	 at 02-01-2010 12:12:46	 
Initial first pole position = 2.473250	 
Ycenter = 0.000213
BscanX : Calibration is up to date.
BscanX : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BscanX : CALIBRATION PROBE:	 poly_calib
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 6001
scans number = 0, threshold = 6000, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 0, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
12:12:50  Move:node 1 absolute position = 0.000400 m
12:12:54  Move:node 2 absolute position = 0.100000 m

Position (counts) fixed:600, secondary:37095
12:13:05  Move:node 1 position incremented by = -0.000086 m

Position (counts) fixed:428, secondary:37095
12:13:14  Move:node 2 position incremented by = 2.436155 m
	 
12:13:54  Move:node 0 absolute position = 0.067000 m
12:14:16  Stage Position Measurement, pos = 0.060020 m
12:14:16  Move:node 0 absolute position = 0.000000 m

VSCAN3: : Time Stamps 0.000000 0.000000 269.233000 290.657000 0.000000 0.000000	 
12:14:37  Move:node 2 absolute position = 0.000000 m
12:14:55  Move:node 1 absolute position = 0.000000 m

-->>12:15:00  VSCAN3:SCAN : 1
start_pos = 0.000000 (m), dist_move = 0.067000 (m), num_samp = 6001, 
 averaging number = 3

Primary axis: 1
Use indexes for travel range:0
Measuring length:0.060000

Secondary axis:3
Was active:1
Accuracy:0.000020
Start position:2.473250
Step size:0.027500
Number of steps:0

Fixed axis:2
Was active:1
Accuracy:0.000001
Position:0.000213

VSCAN3: Indices position error ->  0

VSCAN3: Back jumps number -> 99
VSCAN3: Triggers position error (counts)-> 40

VSCAN3: Fixed position -> 0.0002140
VSCAN3: Fixed position error -> 0.000000
VSCAN3: Fixed Idx position error -> 0.000000


VSCAN3: Secondary position -> 2.4732480
VSCAN3: Secondary position error -> 0.000000
VSCAN3: Secondary Idx position error -> 1.000000


BscanX : Pole number = 1.000000
BscanX : Pole Z-position = 2.473250 m
BscanX : Pole X-center = 0.030749 m
BscanX : Pole field = -0.300689 T
BscanX : Ready for new scan

BscanX : Zero field Y at stop-> voltage:-0.001843	field: -0.000369T
BscanX : Zero field X at stop-> voltage:0.001529	field: 0.000306T
BscanX :  --== BscanX started ==--
 	 at 02-01-2010 12:15:14	 
Initial first pole position = 2.573250	 
Ycenter = 0.000213
BscanX : Calibration is up to date.
BscanX : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BscanX : CALIBRATION PROBE:	 poly_calib
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 6001
scans number = 0, threshold = 6000, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 0, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
12:15:17  Move:node 1 absolute position = 0.000400 m
12:15:22  Move:node 2 absolute position = 0.100000 m

Position (counts) fixed:600, secondary:37095
12:15:33  Move:node 1 position incremented by = -0.000086 m

Position (counts) fixed:428, secondary:37095
12:15:42  Move:node 2 position incremented by = 2.536155 m
	 
12:16:23  Move:node 0 absolute position = 0.067000 m
12:16:44  Stage Position Measurement, pos = 0.060019 m
12:16:44  Move:node 0 absolute position = 0.000000 m

VSCAN3: : Time Stamps 0.000000 0.000000 418.108000 439.522000 0.000000 0.000000	 
12:17:05  Move:node 2 absolute position = 0.000000 m
12:17:25  Move:node 1 absolute position = 0.000000 m

-->>12:17:29  VSCAN3:SCAN : 1
start_pos = 0.000000 (m), dist_move = 0.067000 (m), num_samp = 6001, 
 averaging number = 3

Primary axis: 1
Use indexes for travel range:0
Measuring length:0.060000

Secondary axis:3
Was active:1
Accuracy:0.000020
Start position:2.573250
Step size:0.027500
Number of steps:0

Fixed axis:2
Was active:1
Accuracy:0.000001
Position:0.000213

VSCAN3: Indices position error ->  0

VSCAN3: Back jumps number -> 100
VSCAN3: Triggers position error (counts)-> 40

VSCAN3: Fixed position -> 0.0002140
VSCAN3: Fixed position error -> 0.000000
VSCAN3: Fixed Idx position error -> 0.000000


VSCAN3: Secondary position -> 2.5732480
VSCAN3: Secondary position error -> 1.000000
VSCAN3: Secondary Idx position error -> 1.000000


BscanX : Pole number = 1.000000
BscanX : Pole Z-position = 2.573250 m
BscanX : Pole X-center = 0.030528 m
BscanX : Pole field = 0.112716 T
BscanX : Ready for new scan

BscanX : Zero field Y at stop-> voltage:-0.001843	field: -0.000369T
BscanX : Zero field X at stop-> voltage:0.001506	field: 0.000301T