SLAC Magnetic Measurements
Date: 07-29-2011
Time: 10:26:56

Project: LCLS
Device Type: Undulator
Data Type: Prototype
Serial Number: A1-ANL
DATASET Number: 3
Tuning Stage: Rough Tuning
Run Number: 1
Measurement Type: Align X Scan
Operator: YL
Comment: alignment
 Device:HP3458 , integration time = 0.012000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.012000 , number of channels = 1, number of samples = 0, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.012000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.012000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
10:27:16  Stage Zeroed
10:27:16 Move node 0:  Move Device = CM6K, Read Device = CM6K
*****************************************************************
10:27:16 Move node 1:  Move Device = CM6K, Read Device = CM6K
*****************************************************************
10:27:16 Move node 2:  Move Device = CM6K, Read Device = CM6K
*****************************************************************
10:27:16 Move node 3:  Move Device = CM6K, Read Device = CM6K
*****************************************************************
------------------> get_data <----------------------
10:27:17 : humidity :  57.60
------------------> get_data <----------------------
10:27:17 : pressure : 1001.92
------------------> get_data <----------------------
10:27:17 : ambient : --> Ambient 19.79 --> KGranite 19.89 --> KRefM 19.93 

BscanX :  --== BscanX started ==--
 	 at 07-29-2011 10:27:35	 
Initial first pole position = 0.968634	 
Ycenter = 0.000000
BscanX : Calibration is up to date.
BscanX : CALIBRATION FILE:	 C:\CVI\current_calib\SENIS_463\SENIS_463_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BscanX : CALIBRATION PROBE:	 poly_calib

BscanX : Zero field Y at start-> voltage:0.002442	field: 0.000487T
BscanX : Zero field X at start-> voltage:0.000000	field: 0.000000T
 PXI axis 1: mode = 0 , counts per index = 100000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 7001
scans number = 0, threshold = 7000, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 200000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 47, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 100000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
10:27:46  Move:node 1 absolute position = -0.001500 m
10:27:57  Move:node 2 absolute position = 0.067000 m