SLAC Magnetic Measurements
Date: 12-07-2007
Time: 11:50:51

Project: LCLS
Magnet Type: Dipole
Magnet Name: 002806
Serial Number: 4
Run Number: 2
Measurement Device: 10 Wire
Operator: adf
Comment: Bl vs. I from 0-200 amps and back 20 amp steps

Standardization for :
     3 cycles from    0.0 A to  200.0 A to    0.0 A

Test Currents for  (A):
      0.00     20.00     40.00     60.00     80.00    100.00    120.00    140.00    160.00    180.00    200.00    180.00    160.00    140.00    120.00
    100.00     80.00     60.00     40.00     20.00      0.00

11:51:08  Magnet Current for Main, Imag =       0.0011 A
Vtrans =   0.000011 V, Factor V/A =   0.010000 V/A, Zero Current =   0.000000 A
11:51:09  Magnet Current for Main, Imag =       0.0011 A
Vtrans =   0.000011 V, Factor V/A =   0.010000 V/A, Zero Current =   0.000000 A
11:51:09  Magnet Current for Main, Imag =       0.0011 A
Vtrans =   0.000011 V, Factor V/A =   0.010000 V/A, Zero Current =   0.000000 A
11:51:10  Magnet Current for Main, Imag =       0.0011 A
Vtrans =   0.000011 V, Factor V/A =   0.010000 V/A, Zero Current =   0.000000 A
11:51:10  Magnet Avgerage Current Measurement for Main :
          Imag =       0.0011 +-       0.0000 A
11:52:04  Initial Zero Current Measurement for Main, Imag_zero =   0.00109035 A
11:52:06  POSITION Device(s) Being Used, type = ESP300 Internal Scales
11:52:06  Magnet system Main current ramping to     200.0000 A...