SLAC Magnetic Measurements Date: 07-12-2017 Time: 10:00:45 Project: LCLS-II Magnet Type: Solenoid Magnet Name: 4051 Serial Number: Run Number: 3 Measurement Device: LS460 Operator: sda Comment: Bx,y,z at x,y,z = 0. -10 to 10 A in 0.5 A steps Standardization for Main: 2 cycles from -10.0 A to 10.0 A to -10.0 A Test Currents for Main (A): -10.00 -9.50 -9.00 -8.50 -8.00 -7.50 -7.00 -6.50 -6.00 -5.50 -5.00 -4.50 -4.00 -3.50 -3.00 -2.50 -2.00 -1.50 -1.00 -0.50 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10:00:55 Stage Position Measurement, pos = 0.0000000 m 10:01:02 Move Stage, position = 0.000000 10:01:02 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 10:01:48 Move Stage, position = 0.240000 10:03:18 3 Axis Hall Probe Zeroed 10:03:29 3 Axis Hall Probe Type Being Used, type = LS460 10:04:09 Move Stage, position = 0.000000 10:04:13 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000061 V, Factor V/A = 0.200000 V/A, Zero Current = 0.000000 A 10:04:13 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000062 V, Factor V/A = 0.200000 V/A, Zero Current = 0.000000 A 10:04:14 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000061 V, Factor V/A = 0.200000 V/A, Zero Current = 0.000000 A 10:04:15 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000061 V, Factor V/A = 0.200000 V/A, Zero Current = 0.000000 A 10:04:15 Magnet Avgerage Current Measurement for Main : Imag = -0.0003 +- 0.0000 A 10:04:23 Initial Zero Current Measurement for Main, Imag_zero = -0.000306999 A 10:04:23 Ambient Measurement Device(s) Being Used, type = None 10:04:23 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 10:04:24 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:04:24 XMAG Device(s) Being Used, type = None 10:04:24 Ambient Measurement Device(s) Being Used, type = None 10:04:24 3 Axis Hall Probe Range Set, range = 1 10:04:24 Magnet system Main current ramping to 10.0000 A... 10:04:39 Magnet system Main current ramping to -10.0000 A... 10:04:59 Magnet system Main current ramping to 10.0000 A... 10:05:20 Magnet system Main current ramping to -10.0000 A... 10:05:40 Magnet system Main current ramping to -10.0000 A... 10:05:57 Move Stage, position = 0.000000 10:05:58 Stage Position Measurement, pos = 0.0000400 m 10:05:59 Magnet Current for Main, Imag = -10.0096 A Vtrans = -2.001973 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:00 Magnet Current for Main, Imag = -10.0096 A Vtrans = -2.001973 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:00 Magnet Current for Main, Imag = -10.0096 A Vtrans = -2.001974 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:01 Magnet Current for Main, Imag = -10.0096 A Vtrans = -2.001978 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:01 Magnet Avgerage Current Measurement for Main : Imag = -10.0096 +- 0.0000 A 10:06:02 Magnet Current for Main, Imag = -10.0096 A Vtrans = -2.001973 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:02 Main Volt Voltage Measurement, V = -22.134137 V 10:06:03 Temperature Measurement, Probe Number = 0, T = 29.773000 C 10:06:07 Temperature Measurement, Probe Number = 1, T = 29.530000 C 10:06:07 Temperature Measurement, Probe Number = 2, T = 27.664000 C 10:06:08 Temperature Measurement, Probe Number = 3, T = 28.042000 C 10:06:09 Temperature Measurement, Probe Number = 4, T = 28.735000 C 10:06:09 Temperature Measurement, Probe Number = 5, T = 23.605000 C 10:06:09 Magnet Test Parameter Measurements P0 = Main, Value = -10.01 P1 = Main Volt, Value = -22.13 P2 = RTD Inside, Value = 29.77 P3 = RTD Outside, Value = 29.53 P4 = Supply Water, Value = 27.66 P5 = Return Water, Value = 28.04 P6 = @ RTD Outside, Value = 28.73 P7 = Ambient, Value = 23.61 10:06:09 3 Axis Hall Probe Field Measurement, Bx = 0.000650, By = -0.000400, Bz = 0.094230 T 10:06:15 Move Stage, position = 0.000000 10:06:15 Magnet system Main current ramping to -9.5000 A... 10:06:32 Move Stage, position = 0.000000 10:06:34 Stage Position Measurement, pos = 0.0000400 m 10:06:34 Magnet Current for Main, Imag = -9.5114 A Vtrans = -1.902346 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:35 Magnet Current for Main, Imag = -9.5115 A Vtrans = -1.902354 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:36 Magnet Current for Main, Imag = -9.5115 A Vtrans = -1.902352 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:36 Magnet Current for Main, Imag = -9.5115 A Vtrans = -1.902359 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:36 Magnet Avgerage Current Measurement for Main : Imag = -9.5115 +- 0.0000 A 10:06:37 Magnet Current for Main, Imag = -9.5115 A Vtrans = -1.902357 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:06:38 Main Volt Voltage Measurement, V = -21.114217 V 10:06:38 Temperature Measurement, Probe Number = 0, T = 30.130000 C 10:06:42 Temperature Measurement, Probe Number = 1, T = 29.974000 C 10:06:43 Temperature Measurement, Probe Number = 2, T = 27.612000 C 10:06:43 Temperature Measurement, Probe Number = 3, T = 28.043000 C 10:06:44 Temperature Measurement, Probe Number = 4, T = 29.032000 C 10:06:44 Temperature Measurement, Probe Number = 5, T = 23.451000 C 10:06:44 Magnet Test Parameter Measurements P0 = Main, Value = -9.51 P1 = Main Volt, Value = -21.11 P2 = RTD Inside, Value = 30.13 P3 = RTD Outside, Value = 29.97 P4 = Supply Water, Value = 27.61 P5 = Return Water, Value = 28.04 P6 = @ RTD Outside, Value = 29.03 P7 = Ambient, Value = 23.45 10:06:44 3 Axis Hall Probe Field Measurement, Bx = 0.000620, By = -0.000390, Bz = 0.089550 T 10:06:50 Move Stage, position = 0.000000 10:06:50 Magnet system Main current ramping to -9.0000 A... 10:07:07 Move Stage, position = 0.000000 10:07:09 Stage Position Measurement, pos = 0.0000400 m 10:07:10 Magnet Current for Main, Imag = -9.0077 A Vtrans = -1.801602 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:10 Magnet Current for Main, Imag = -9.0077 A Vtrans = -1.801601 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:11 Magnet Current for Main, Imag = -9.0077 A Vtrans = -1.801600 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:12 Magnet Current for Main, Imag = -9.0077 A Vtrans = -1.801602 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:12 Magnet Avgerage Current Measurement for Main : Imag = -9.0077 +- 0.0000 A 10:07:12 Magnet Current for Main, Imag = -9.0077 A Vtrans = -1.801600 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:13 Main Volt Voltage Measurement, V = -20.054596 V 10:07:14 Temperature Measurement, Probe Number = 0, T = 30.451000 C 10:07:17 Temperature Measurement, Probe Number = 1, T = 30.387000 C 10:07:18 Temperature Measurement, Probe Number = 2, T = 27.596000 C 10:07:18 Temperature Measurement, Probe Number = 3, T = 28.075000 C 10:07:19 Temperature Measurement, Probe Number = 4, T = 29.338000 C 10:07:20 Temperature Measurement, Probe Number = 5, T = 23.506000 C 10:07:20 Magnet Test Parameter Measurements P0 = Main, Value = -9.01 P1 = Main Volt, Value = -20.05 P2 = RTD Inside, Value = 30.45 P3 = RTD Outside, Value = 30.39 P4 = Supply Water, Value = 27.60 P5 = Return Water, Value = 28.07 P6 = @ RTD Outside, Value = 29.34 P7 = Ambient, Value = 23.51 10:07:20 3 Axis Hall Probe Field Measurement, Bx = 0.000590, By = -0.000370, Bz = 0.084810 T 10:07:26 Move Stage, position = 0.000000 10:07:26 Magnet system Main current ramping to -8.5000 A... 10:07:42 Move Stage, position = 0.000000 10:07:44 Stage Position Measurement, pos = 0.0000400 m 10:07:45 Magnet Current for Main, Imag = -8.5086 A Vtrans = -1.701782 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:45 Magnet Current for Main, Imag = -8.5086 A Vtrans = -1.701779 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:46 Magnet Current for Main, Imag = -8.5086 A Vtrans = -1.701779 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:47 Magnet Current for Main, Imag = -8.5086 A Vtrans = -1.701776 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:47 Magnet Avgerage Current Measurement for Main : Imag = -8.5086 +- 0.0000 A 10:07:48 Magnet Current for Main, Imag = -8.5086 A Vtrans = -1.701785 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:07:48 Main Volt Voltage Measurement, V = -18.984414 V 10:07:49 Temperature Measurement, Probe Number = 0, T = 30.733000 C 10:07:52 Temperature Measurement, Probe Number = 1, T = 30.757000 C 10:07:53 Temperature Measurement, Probe Number = 2, T = 27.601000 C 10:07:54 Temperature Measurement, Probe Number = 3, T = 28.152000 C 10:07:54 Temperature Measurement, Probe Number = 4, T = 29.649000 C 10:07:55 Temperature Measurement, Probe Number = 5, T = 23.568000 C 10:07:55 Magnet Test Parameter Measurements P0 = Main, Value = -8.51 P1 = Main Volt, Value = -18.98 P2 = RTD Inside, Value = 30.73 P3 = RTD Outside, Value = 30.76 P4 = Supply Water, Value = 27.60 P5 = Return Water, Value = 28.15 P6 = @ RTD Outside, Value = 29.65 P7 = Ambient, Value = 23.57 10:07:55 3 Axis Hall Probe Field Measurement, Bx = 0.000560, By = -0.000340, Bz = 0.080130 T 10:08:01 Move Stage, position = 0.000000 10:08:01 Magnet system Main current ramping to -8.0000 A... 10:08:17 Move Stage, position = 0.000000 10:08:19 Stage Position Measurement, pos = 0.0000400 m 10:08:20 Magnet Current for Main, Imag = -8.0096 A Vtrans = -1.601990 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:21 Magnet Current for Main, Imag = -8.0097 A Vtrans = -1.601992 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:21 Magnet Current for Main, Imag = -8.0097 A Vtrans = -1.601995 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:22 Magnet Current for Main, Imag = -8.0096 A Vtrans = -1.601990 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:22 Magnet Avgerage Current Measurement for Main : Imag = -8.0097 +- 0.0000 A 10:08:23 Magnet Current for Main, Imag = -8.0097 A Vtrans = -1.601995 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:23 Main Volt Voltage Measurement, V = -17.898155 V 10:08:24 Temperature Measurement, Probe Number = 0, T = 30.962000 C 10:08:28 Temperature Measurement, Probe Number = 1, T = 31.065000 C 10:08:28 Temperature Measurement, Probe Number = 2, T = 27.447000 C 10:08:29 Temperature Measurement, Probe Number = 3, T = 28.178000 C 10:08:29 Temperature Measurement, Probe Number = 4, T = 29.930000 C 10:08:30 Temperature Measurement, Probe Number = 5, T = 23.532000 C 10:08:30 Magnet Test Parameter Measurements P0 = Main, Value = -8.01 P1 = Main Volt, Value = -17.90 P2 = RTD Inside, Value = 30.96 P3 = RTD Outside, Value = 31.07 P4 = Supply Water, Value = 27.45 P5 = Return Water, Value = 28.18 P6 = @ RTD Outside, Value = 29.93 P7 = Ambient, Value = 23.53 10:08:30 3 Axis Hall Probe Field Measurement, Bx = 0.000530, By = -0.000330, Bz = 0.075430 T 10:08:36 Move Stage, position = 0.000000 10:08:36 Magnet system Main current ramping to -7.5000 A... 10:08:53 Move Stage, position = 0.000000 10:08:54 Stage Position Measurement, pos = 0.0000400 m 10:08:55 Magnet Current for Main, Imag = -7.5092 A Vtrans = -1.501897 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:56 Magnet Current for Main, Imag = -7.5092 A Vtrans = -1.501897 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:56 Magnet Current for Main, Imag = -7.5092 A Vtrans = -1.501901 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:57 Magnet Current for Main, Imag = -7.5092 A Vtrans = -1.501896 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:57 Magnet Avgerage Current Measurement for Main : Imag = -7.5092 +- 0.0000 A 10:08:58 Magnet Current for Main, Imag = -7.5092 A Vtrans = -1.501896 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:08:58 Main Volt Voltage Measurement, V = -16.795932 V 10:08:59 Temperature Measurement, Probe Number = 0, T = 31.134000 C 10:09:03 Temperature Measurement, Probe Number = 1, T = 31.293000 C 10:09:03 Temperature Measurement, Probe Number = 2, T = 27.324000 C 10:09:04 Temperature Measurement, Probe Number = 3, T = 28.223000 C 10:09:04 Temperature Measurement, Probe Number = 4, T = 30.162000 C 10:09:05 Temperature Measurement, Probe Number = 5, T = 23.554000 C 10:09:05 Magnet Test Parameter Measurements P0 = Main, Value = -7.51 P1 = Main Volt, Value = -16.80 P2 = RTD Inside, Value = 31.13 P3 = RTD Outside, Value = 31.29 P4 = Supply Water, Value = 27.32 P5 = Return Water, Value = 28.22 P6 = @ RTD Outside, Value = 30.16 P7 = Ambient, Value = 23.55 10:09:05 3 Axis Hall Probe Field Measurement, Bx = 0.000500, By = -0.000300, Bz = 0.070730 T 10:09:11 Move Stage, position = 0.000000 10:09:11 Magnet system Main current ramping to -7.0000 A... 10:09:28 Move Stage, position = 0.000000 10:09:29 Stage Position Measurement, pos = 0.0000400 m 10:09:30 Magnet Current for Main, Imag = -7.0031 A Vtrans = -1.400689 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:09:31 Magnet Current for Main, Imag = -7.0031 A Vtrans = -1.400685 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:09:32 Magnet Current for Main, Imag = -7.0031 A Vtrans = -1.400685 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:09:32 Magnet Current for Main, Imag = -7.0031 A Vtrans = -1.400688 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:09:32 Magnet Avgerage Current Measurement for Main : Imag = -7.0031 +- 0.0000 A 10:09:33 Magnet Current for Main, Imag = -7.0031 A Vtrans = -1.400685 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:09:34 Main Volt Voltage Measurement, V = -15.671550 V 10:09:34 Temperature Measurement, Probe Number = 0, T = 31.250000 C 10:09:38 Temperature Measurement, Probe Number = 1, T = 31.449000 C 10:09:38 Temperature Measurement, Probe Number = 2, T = 27.358000 C 10:09:39 Temperature Measurement, Probe Number = 3, T = 28.214000 C 10:09:40 Temperature Measurement, Probe Number = 4, T = 30.352000 C 10:09:40 Temperature Measurement, Probe Number = 5, T = 23.478000 C 10:09:40 Magnet Test Parameter Measurements P0 = Main, Value = -7.00 P1 = Main Volt, Value = -15.67 P2 = RTD Inside, Value = 31.25 P3 = RTD Outside, Value = 31.45 P4 = Supply Water, Value = 27.36 P5 = Return Water, Value = 28.21 P6 = @ RTD Outside, Value = 30.35 P7 = Ambient, Value = 23.48 10:09:40 3 Axis Hall Probe Field Measurement, Bx = 0.000460, By = -0.000290, Bz = 0.065950 T 10:09:46 Move Stage, position = 0.000000 10:09:46 Magnet system Main current ramping to -6.5000 A... 10:10:03 Move Stage, position = 0.000000 10:10:05 Stage Position Measurement, pos = 0.0000400 m 10:10:05 Magnet Current for Main, Imag = -6.5074 A Vtrans = -1.301544 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:06 Magnet Current for Main, Imag = -6.5074 A Vtrans = -1.301540 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:07 Magnet Current for Main, Imag = -6.5074 A Vtrans = -1.301539 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:07 Magnet Current for Main, Imag = -6.5074 A Vtrans = -1.301545 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:07 Magnet Avgerage Current Measurement for Main : Imag = -6.5074 +- 0.0000 A 10:10:08 Magnet Current for Main, Imag = -6.5074 A Vtrans = -1.301540 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:09 Main Volt Voltage Measurement, V = -14.563285 V 10:10:09 Temperature Measurement, Probe Number = 0, T = 31.322000 C 10:10:13 Temperature Measurement, Probe Number = 1, T = 31.539000 C 10:10:14 Temperature Measurement, Probe Number = 2, T = 27.444000 C 10:10:14 Temperature Measurement, Probe Number = 3, T = 28.150000 C 10:10:15 Temperature Measurement, Probe Number = 4, T = 30.475000 C 10:10:15 Temperature Measurement, Probe Number = 5, T = 23.484000 C 10:10:15 Magnet Test Parameter Measurements P0 = Main, Value = -6.51 P1 = Main Volt, Value = -14.56 P2 = RTD Inside, Value = 31.32 P3 = RTD Outside, Value = 31.54 P4 = Supply Water, Value = 27.44 P5 = Return Water, Value = 28.15 P6 = @ RTD Outside, Value = 30.48 P7 = Ambient, Value = 23.48 10:10:15 3 Axis Hall Probe Field Measurement, Bx = 0.000430, By = -0.000260, Bz = 0.061290 T 10:10:21 Move Stage, position = 0.000000 10:10:21 Magnet system Main current ramping to -6.0000 A... 10:10:38 Move Stage, position = 0.000000 10:10:40 Stage Position Measurement, pos = 0.0000400 m 10:10:40 Magnet Current for Main, Imag = -6.0106 A Vtrans = -1.202191 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:41 Magnet Current for Main, Imag = -6.0107 A Vtrans = -1.202193 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:42 Magnet Current for Main, Imag = -6.0107 A Vtrans = -1.202196 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:43 Magnet Current for Main, Imag = -6.0107 A Vtrans = -1.202195 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:43 Magnet Avgerage Current Measurement for Main : Imag = -6.0107 +- 0.0000 A 10:10:43 Magnet Current for Main, Imag = -6.0107 A Vtrans = -1.202195 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:10:44 Main Volt Voltage Measurement, V = -13.448128 V 10:10:45 Temperature Measurement, Probe Number = 0, T = 31.348000 C 10:10:48 Temperature Measurement, Probe Number = 1, T = 31.578000 C 10:10:49 Temperature Measurement, Probe Number = 2, T = 27.497000 C 10:10:49 Temperature Measurement, Probe Number = 3, T = 28.082000 C 10:10:50 Temperature Measurement, Probe Number = 4, T = 30.552000 C 10:10:50 Temperature Measurement, Probe Number = 5, T = 23.417000 C 10:10:50 Magnet Test Parameter Measurements P0 = Main, Value = -6.01 P1 = Main Volt, Value = -13.45 P2 = RTD Inside, Value = 31.35 P3 = RTD Outside, Value = 31.58 P4 = Supply Water, Value = 27.50 P5 = Return Water, Value = 28.08 P6 = @ RTD Outside, Value = 30.55 P7 = Ambient, Value = 23.42 10:10:51 3 Axis Hall Probe Field Measurement, Bx = 0.000400, By = -0.000240, Bz = 0.056610 T 10:10:57 Move Stage, position = 0.000000 10:10:57 Magnet system Main current ramping to -5.5000 A... 10:11:13 Move Stage, position = 0.000000 10:11:15 Stage Position Measurement, pos = 0.0000400 m 10:11:16 Magnet Current for Main, Imag = -5.5089 A Vtrans = -1.101844 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:16 Magnet Current for Main, Imag = -5.5089 A Vtrans = -1.101850 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:17 Magnet Current for Main, Imag = -5.5089 A Vtrans = -1.101844 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:18 Magnet Current for Main, Imag = -5.5089 A Vtrans = -1.101844 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:18 Magnet Avgerage Current Measurement for Main : Imag = -5.5089 +- 0.0000 A 10:11:18 Magnet Current for Main, Imag = -5.5089 A Vtrans = -1.101845 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:19 Main Volt Voltage Measurement, V = -12.318954 V 10:11:20 Temperature Measurement, Probe Number = 0, T = 31.342000 C 10:11:23 Temperature Measurement, Probe Number = 1, T = 31.577000 C 10:11:24 Temperature Measurement, Probe Number = 2, T = 27.551000 C 10:11:24 Temperature Measurement, Probe Number = 3, T = 28.122000 C 10:11:25 Temperature Measurement, Probe Number = 4, T = 30.601000 C 10:11:26 Temperature Measurement, Probe Number = 5, T = 23.468000 C 10:11:26 Magnet Test Parameter Measurements P0 = Main, Value = -5.51 P1 = Main Volt, Value = -12.32 P2 = RTD Inside, Value = 31.34 P3 = RTD Outside, Value = 31.58 P4 = Supply Water, Value = 27.55 P5 = Return Water, Value = 28.12 P6 = @ RTD Outside, Value = 30.60 P7 = Ambient, Value = 23.47 10:11:26 3 Axis Hall Probe Field Measurement, Bx = 0.000370, By = -0.000220, Bz = 0.051890 T 10:11:32 Move Stage, position = 0.000000 10:11:32 Magnet system Main current ramping to -5.0000 A... 10:11:48 Move Stage, position = 0.000000 10:11:50 Stage Position Measurement, pos = 0.0000400 m 10:11:51 Magnet Current for Main, Imag = -5.0076 A Vtrans = -1.001587 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:52 Magnet Current for Main, Imag = -5.0076 A Vtrans = -1.001589 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:52 Magnet Current for Main, Imag = -5.0076 A Vtrans = -1.001584 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:53 Magnet Current for Main, Imag = -5.0076 A Vtrans = -1.001585 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:53 Magnet Avgerage Current Measurement for Main : Imag = -5.0076 +- 0.0000 A 10:11:54 Magnet Current for Main, Imag = -5.0076 A Vtrans = -1.001588 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:11:54 Main Volt Voltage Measurement, V = -11.189520 V 10:11:55 Temperature Measurement, Probe Number = 0, T = 31.320000 C 10:11:58 Temperature Measurement, Probe Number = 1, T = 31.547000 C 10:11:59 Temperature Measurement, Probe Number = 2, T = 27.575000 C 10:12:00 Temperature Measurement, Probe Number = 3, T = 28.189000 C 10:12:00 Temperature Measurement, Probe Number = 4, T = 30.603000 C 10:12:01 Temperature Measurement, Probe Number = 5, T = 23.550000 C 10:12:01 Magnet Test Parameter Measurements P0 = Main, Value = -5.01 P1 = Main Volt, Value = -11.19 P2 = RTD Inside, Value = 31.32 P3 = RTD Outside, Value = 31.55 P4 = Supply Water, Value = 27.57 P5 = Return Water, Value = 28.19 P6 = @ RTD Outside, Value = 30.60 P7 = Ambient, Value = 23.55 10:12:01 3 Axis Hall Probe Field Measurement, Bx = 0.000340, By = -0.000190, Bz = 0.047180 T 10:12:07 Move Stage, position = 0.000000 10:12:07 Magnet system Main current ramping to -4.5000 A... 10:12:24 Move Stage, position = 0.000000 10:12:26 Stage Position Measurement, pos = 0.0000400 m 10:12:26 Magnet Current for Main, Imag = -4.5052 A Vtrans = -0.901110 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:12:27 Magnet Current for Main, Imag = -4.5052 A Vtrans = -0.901108 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:12:28 Magnet Current for Main, Imag = -4.5052 A Vtrans = -0.901111 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:12:29 Magnet Current for Main, Imag = -4.5052 A Vtrans = -0.901110 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:12:29 Magnet Avgerage Current Measurement for Main : Imag = -4.5052 +- 0.0000 A 10:12:29 Magnet Current for Main, Imag = -4.5053 A Vtrans = -0.901112 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:12:30 Main Volt Voltage Measurement, V = -10.057357 V 10:12:30 Temperature Measurement, Probe Number = 0, T = 31.277000 C 10:12:34 Temperature Measurement, Probe Number = 1, T = 31.488000 C 10:12:35 Temperature Measurement, Probe Number = 2, T = 27.615000 C 10:12:35 Temperature Measurement, Probe Number = 3, T = 28.268000 C 10:12:36 Temperature Measurement, Probe Number = 4, T = 30.580000 C 10:12:36 Temperature Measurement, Probe Number = 5, T = 23.603000 C 10:12:36 Magnet Test Parameter Measurements P0 = Main, Value = -4.51 P1 = Main Volt, Value = -10.06 P2 = RTD Inside, Value = 31.28 P3 = RTD Outside, Value = 31.49 P4 = Supply Water, Value = 27.61 P5 = Return Water, Value = 28.27 P6 = @ RTD Outside, Value = 30.58 P7 = Ambient, Value = 23.60 10:12:36 3 Axis Hall Probe Field Measurement, Bx = 0.000300, By = -0.000170, Bz = 0.042460 T 10:12:43 Move Stage, position = 0.000000 10:12:43 Magnet system Main current ramping to -4.0000 A... 10:12:59 Move Stage, position = 0.000000 10:13:01 Stage Position Measurement, pos = 0.0000400 m 10:13:02 Magnet Current for Main, Imag = -4.0069 A Vtrans = -0.801443 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:02 Magnet Current for Main, Imag = -4.0069 A Vtrans = -0.801439 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:03 Magnet Current for Main, Imag = -4.0069 A Vtrans = -0.801440 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:04 Magnet Current for Main, Imag = -4.0069 A Vtrans = -0.801442 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:04 Magnet Avgerage Current Measurement for Main : Imag = -4.0069 +- 0.0000 A 10:13:04 Magnet Current for Main, Imag = -4.0069 A Vtrans = -0.801443 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:05 Main Volt Voltage Measurement, V = -8.935431 V 10:13:06 Temperature Measurement, Probe Number = 0, T = 31.212000 C 10:13:09 Temperature Measurement, Probe Number = 1, T = 31.410000 C 10:13:10 Temperature Measurement, Probe Number = 2, T = 27.521000 C 10:13:10 Temperature Measurement, Probe Number = 3, T = 28.290000 C 10:13:11 Temperature Measurement, Probe Number = 4, T = 30.544000 C 10:13:12 Temperature Measurement, Probe Number = 5, T = 23.517000 C 10:13:12 Magnet Test Parameter Measurements P0 = Main, Value = -4.01 P1 = Main Volt, Value = -8.94 P2 = RTD Inside, Value = 31.21 P3 = RTD Outside, Value = 31.41 P4 = Supply Water, Value = 27.52 P5 = Return Water, Value = 28.29 P6 = @ RTD Outside, Value = 30.54 P7 = Ambient, Value = 23.52 10:13:12 3 Axis Hall Probe Field Measurement, Bx = 0.000270, By = -0.000160, Bz = 0.037750 T 10:13:18 Move Stage, position = 0.000000 10:13:18 Magnet system Main current ramping to -3.5000 A... 10:13:34 Move Stage, position = 0.000000 10:13:36 Stage Position Measurement, pos = 0.0000400 m 10:13:37 Magnet Current for Main, Imag = -3.5048 A Vtrans = -0.701027 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:37 Magnet Current for Main, Imag = -3.5048 A Vtrans = -0.701024 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:38 Magnet Current for Main, Imag = -3.5048 A Vtrans = -0.701025 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:39 Magnet Current for Main, Imag = -3.5048 A Vtrans = -0.701025 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:39 Magnet Avgerage Current Measurement for Main : Imag = -3.5048 +- 0.0000 A 10:13:40 Magnet Current for Main, Imag = -3.5048 A Vtrans = -0.701025 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:13:40 Main Volt Voltage Measurement, V = -7.806650 V 10:13:41 Temperature Measurement, Probe Number = 0, T = 31.121000 C 10:13:44 Temperature Measurement, Probe Number = 1, T = 31.306000 C 10:13:45 Temperature Measurement, Probe Number = 2, T = 27.478000 C 10:13:46 Temperature Measurement, Probe Number = 3, T = 28.280000 C 10:13:46 Temperature Measurement, Probe Number = 4, T = 30.486000 C 10:13:47 Temperature Measurement, Probe Number = 5, T = 23.504000 C 10:13:47 Magnet Test Parameter Measurements P0 = Main, Value = -3.50 P1 = Main Volt, Value = -7.81 P2 = RTD Inside, Value = 31.12 P3 = RTD Outside, Value = 31.31 P4 = Supply Water, Value = 27.48 P5 = Return Water, Value = 28.28 P6 = @ RTD Outside, Value = 30.49 P7 = Ambient, Value = 23.50 10:13:47 3 Axis Hall Probe Field Measurement, Bx = 0.000240, By = -0.000140, Bz = 0.033020 T 10:13:53 Move Stage, position = 0.000000 10:13:53 Magnet system Main current ramping to -3.0000 A... 10:14:10 Move Stage, position = 0.000000 10:14:11 Stage Position Measurement, pos = 0.0000400 m 10:14:12 Magnet Current for Main, Imag = -3.0073 A Vtrans = -0.601522 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:13 Magnet Current for Main, Imag = -3.0073 A Vtrans = -0.601525 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:13 Magnet Current for Main, Imag = -3.0073 A Vtrans = -0.601524 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:14 Magnet Current for Main, Imag = -3.0073 A Vtrans = -0.601522 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:14 Magnet Avgerage Current Measurement for Main : Imag = -3.0073 +- 0.0000 A 10:14:15 Magnet Current for Main, Imag = -3.0073 A Vtrans = -0.601525 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:15 Main Volt Voltage Measurement, V = -6.690208 V 10:14:16 Temperature Measurement, Probe Number = 0, T = 31.011000 C 10:14:20 Temperature Measurement, Probe Number = 1, T = 31.173000 C 10:14:20 Temperature Measurement, Probe Number = 2, T = 27.485000 C 10:14:21 Temperature Measurement, Probe Number = 3, T = 28.280000 C 10:14:21 Temperature Measurement, Probe Number = 4, T = 30.409000 C 10:14:22 Temperature Measurement, Probe Number = 5, T = 23.477000 C 10:14:22 Magnet Test Parameter Measurements P0 = Main, Value = -3.01 P1 = Main Volt, Value = -6.69 P2 = RTD Inside, Value = 31.01 P3 = RTD Outside, Value = 31.17 P4 = Supply Water, Value = 27.48 P5 = Return Water, Value = 28.28 P6 = @ RTD Outside, Value = 30.41 P7 = Ambient, Value = 23.48 10:14:22 3 Axis Hall Probe Field Measurement, Bx = 0.000200, By = -0.000120, Bz = 0.028350 T 10:14:28 Move Stage, position = 0.000000 10:14:28 Magnet system Main current ramping to -2.5000 A... 10:14:45 Move Stage, position = 0.000000 10:14:46 Stage Position Measurement, pos = 0.0000400 m 10:14:47 Magnet Current for Main, Imag = -2.5053 A Vtrans = -0.501112 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:48 Magnet Current for Main, Imag = -2.5053 A Vtrans = -0.501112 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:48 Magnet Current for Main, Imag = -2.5053 A Vtrans = -0.501112 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:49 Magnet Current for Main, Imag = -2.5053 A Vtrans = -0.501112 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:49 Magnet Avgerage Current Measurement for Main : Imag = -2.5053 +- 0.0000 A 10:14:50 Magnet Current for Main, Imag = -2.5053 A Vtrans = -0.501113 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:14:50 Main Volt Voltage Measurement, V = -5.566268 V 10:14:51 Temperature Measurement, Probe Number = 0, T = 30.898000 C 10:14:55 Temperature Measurement, Probe Number = 1, T = 31.030000 C 10:14:55 Temperature Measurement, Probe Number = 2, T = 27.561000 C 10:14:56 Temperature Measurement, Probe Number = 3, T = 28.282000 C 10:14:56 Temperature Measurement, Probe Number = 4, T = 30.303000 C 10:14:57 Temperature Measurement, Probe Number = 5, T = 23.546000 C 10:14:57 Magnet Test Parameter Measurements P0 = Main, Value = -2.51 P1 = Main Volt, Value = -5.57 P2 = RTD Inside, Value = 30.90 P3 = RTD Outside, Value = 31.03 P4 = Supply Water, Value = 27.56 P5 = Return Water, Value = 28.28 P6 = @ RTD Outside, Value = 30.30 P7 = Ambient, Value = 23.55 10:14:57 3 Axis Hall Probe Field Measurement, Bx = 0.000170, By = -0.000100, Bz = 0.023610 T 10:15:03 Move Stage, position = 0.000000 10:15:03 Magnet system Main current ramping to -2.0000 A... 10:15:20 Move Stage, position = 0.000000 10:15:21 Stage Position Measurement, pos = 0.0000400 m 10:15:22 Magnet Current for Main, Imag = -2.0031 A Vtrans = -0.400680 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:23 Magnet Current for Main, Imag = -2.0031 A Vtrans = -0.400680 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:24 Magnet Current for Main, Imag = -2.0031 A Vtrans = -0.400679 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:24 Magnet Current for Main, Imag = -2.0031 A Vtrans = -0.400681 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:24 Magnet Avgerage Current Measurement for Main : Imag = -2.0031 +- 0.0000 A 10:15:25 Magnet Current for Main, Imag = -2.0031 A Vtrans = -0.400679 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:26 Main Volt Voltage Measurement, V = -4.444915 V 10:15:26 Temperature Measurement, Probe Number = 0, T = 30.785000 C 10:15:30 Temperature Measurement, Probe Number = 1, T = 30.890000 C 10:15:30 Temperature Measurement, Probe Number = 2, T = 27.559000 C 10:15:31 Temperature Measurement, Probe Number = 3, T = 28.300000 C 10:15:32 Temperature Measurement, Probe Number = 4, T = 30.192000 C 10:15:32 Temperature Measurement, Probe Number = 5, T = 23.645000 C 10:15:32 Magnet Test Parameter Measurements P0 = Main, Value = -2.00 P1 = Main Volt, Value = -4.44 P2 = RTD Inside, Value = 30.79 P3 = RTD Outside, Value = 30.89 P4 = Supply Water, Value = 27.56 P5 = Return Water, Value = 28.30 P6 = @ RTD Outside, Value = 30.19 P7 = Ambient, Value = 23.64 10:15:32 3 Axis Hall Probe Field Measurement, Bx = 0.000140, By = -0.000070, Bz = 0.018890 T 10:15:38 Move Stage, position = 0.000000 10:15:38 Magnet system Main current ramping to -1.5000 A... 10:15:55 Move Stage, position = 0.000000 10:15:57 Stage Position Measurement, pos = 0.0000400 m 10:15:57 Magnet Current for Main, Imag = -1.5051 A Vtrans = -0.301079 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:58 Magnet Current for Main, Imag = -1.5051 A Vtrans = -0.301081 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:59 Magnet Current for Main, Imag = -1.5051 A Vtrans = -0.301081 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:59 Magnet Current for Main, Imag = -1.5051 A Vtrans = -0.301081 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:15:59 Magnet Avgerage Current Measurement for Main : Imag = -1.5051 +- 0.0000 A 10:16:00 Magnet Current for Main, Imag = -1.5051 A Vtrans = -0.301082 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:01 Main Volt Voltage Measurement, V = -3.335682 V 10:16:01 Temperature Measurement, Probe Number = 0, T = 30.664000 C 10:16:05 Temperature Measurement, Probe Number = 1, T = 30.742000 C 10:16:06 Temperature Measurement, Probe Number = 2, T = 27.558000 C 10:16:06 Temperature Measurement, Probe Number = 3, T = 28.296000 C 10:16:07 Temperature Measurement, Probe Number = 4, T = 30.083000 C 10:16:07 Temperature Measurement, Probe Number = 5, T = 23.583000 C 10:16:07 Magnet Test Parameter Measurements P0 = Main, Value = -1.51 P1 = Main Volt, Value = -3.34 P2 = RTD Inside, Value = 30.66 P3 = RTD Outside, Value = 30.74 P4 = Supply Water, Value = 27.56 P5 = Return Water, Value = 28.30 P6 = @ RTD Outside, Value = 30.08 P7 = Ambient, Value = 23.58 10:16:07 3 Axis Hall Probe Field Measurement, Bx = 0.000110, By = -0.000060, Bz = 0.014200 T 10:16:13 Move Stage, position = 0.000000 10:16:13 Magnet system Main current ramping to -1.0000 A... 10:16:30 Move Stage, position = 0.000000 10:16:32 Stage Position Measurement, pos = 0.0000400 m 10:16:33 Magnet Current for Main, Imag = -1.0023 A Vtrans = -0.200524 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:33 Magnet Current for Main, Imag = -1.0023 A Vtrans = -0.200523 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:34 Magnet Current for Main, Imag = -1.0023 A Vtrans = -0.200522 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:35 Magnet Current for Main, Imag = -1.0023 A Vtrans = -0.200523 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:35 Magnet Avgerage Current Measurement for Main : Imag = -1.0023 +- 0.0000 A 10:16:35 Magnet Current for Main, Imag = -1.0023 A Vtrans = -0.200523 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:16:36 Main Volt Voltage Measurement, V = -2.218684 V 10:16:37 Temperature Measurement, Probe Number = 0, T = 30.536000 C 10:16:40 Temperature Measurement, Probe Number = 1, T = 30.592000 C 10:16:41 Temperature Measurement, Probe Number = 2, T = 27.582000 C 10:16:41 Temperature Measurement, Probe Number = 3, T = 28.239000 C 10:16:42 Temperature Measurement, Probe Number = 4, T = 29.960000 C 10:16:43 Temperature Measurement, Probe Number = 5, T = 23.486000 C 10:16:43 Magnet Test Parameter Measurements P0 = Main, Value = -1.00 P1 = Main Volt, Value = -2.22 P2 = RTD Inside, Value = 30.54 P3 = RTD Outside, Value = 30.59 P4 = Supply Water, Value = 27.58 P5 = Return Water, Value = 28.24 P6 = @ RTD Outside, Value = 29.96 P7 = Ambient, Value = 23.49 10:16:43 3 Axis Hall Probe Field Measurement, Bx = 0.000080, By = -0.000040, Bz = 0.009470 T 10:16:49 Move Stage, position = 0.000000 10:16:49 Magnet system Main current ramping to -0.5000 A... 10:17:05 Move Stage, position = 0.000000 10:17:07 Stage Position Measurement, pos = 0.0000400 m 10:17:08 Magnet Current for Main, Imag = -0.5019 A Vtrans = -0.100437 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:08 Magnet Current for Main, Imag = -0.5019 A Vtrans = -0.100435 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:09 Magnet Current for Main, Imag = -0.5019 A Vtrans = -0.100439 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:10 Magnet Current for Main, Imag = -0.5019 A Vtrans = -0.100437 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:10 Magnet Avgerage Current Measurement for Main : Imag = -0.5019 +- 0.0000 A 10:17:11 Magnet Current for Main, Imag = -0.5019 A Vtrans = -0.100440 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:11 Main Volt Voltage Measurement, V = -1.109690 V 10:17:12 Temperature Measurement, Probe Number = 0, T = 30.415000 C 10:17:15 Temperature Measurement, Probe Number = 1, T = 30.435000 C 10:17:16 Temperature Measurement, Probe Number = 2, T = 27.528000 C 10:17:17 Temperature Measurement, Probe Number = 3, T = 28.213000 C 10:17:17 Temperature Measurement, Probe Number = 4, T = 29.823000 C 10:17:18 Temperature Measurement, Probe Number = 5, T = 23.543000 C 10:17:18 Magnet Test Parameter Measurements P0 = Main, Value = -0.50 P1 = Main Volt, Value = -1.11 P2 = RTD Inside, Value = 30.41 P3 = RTD Outside, Value = 30.43 P4 = Supply Water, Value = 27.53 P5 = Return Water, Value = 28.21 P6 = @ RTD Outside, Value = 29.82 P7 = Ambient, Value = 23.54 10:17:18 3 Axis Hall Probe Field Measurement, Bx = 0.000040, By = -0.000010, Bz = 0.004760 T 10:17:24 Move Stage, position = 0.000000 10:17:24 Magnet system Main current ramping to 0.0000 A... 10:17:41 Move Stage, position = 0.000000 10:17:42 Stage Position Measurement, pos = 0.0000400 m 10:17:43 Magnet Current for Main, Imag = -0.0019 A Vtrans = -0.000448 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:44 Magnet Current for Main, Imag = -0.0019 A Vtrans = -0.000449 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:44 Magnet Current for Main, Imag = -0.0019 A Vtrans = -0.000447 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:45 Magnet Current for Main, Imag = -0.0019 A Vtrans = -0.000449 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:45 Magnet Avgerage Current Measurement for Main : Imag = -0.0019 +- 0.0000 A 10:17:46 Magnet Current for Main, Imag = -0.0019 A Vtrans = -0.000449 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:17:46 Main Volt Voltage Measurement, V = -0.004303 V 10:17:47 Temperature Measurement, Probe Number = 0, T = 30.303000 C 10:17:51 Temperature Measurement, Probe Number = 1, T = 30.291000 C 10:17:51 Temperature Measurement, Probe Number = 2, T = 27.583000 C 10:17:52 Temperature Measurement, Probe Number = 3, T = 28.142000 C 10:17:52 Temperature Measurement, Probe Number = 4, T = 29.693000 C 10:17:53 Temperature Measurement, Probe Number = 5, T = 23.554000 C 10:17:53 Magnet Test Parameter Measurements P0 = Main, Value = -0.00 P1 = Main Volt, Value = -0.00 P2 = RTD Inside, Value = 30.30 P3 = RTD Outside, Value = 30.29 P4 = Supply Water, Value = 27.58 P5 = Return Water, Value = 28.14 P6 = @ RTD Outside, Value = 29.69 P7 = Ambient, Value = 23.55 10:17:53 3 Axis Hall Probe Field Measurement, Bx = 0.000010, By = 0.000000, Bz = 0.000040 T 10:17:59 Move Stage, position = 0.000000 10:17:59 Magnet system Main current ramping to 0.5000 A... 10:18:16 Move Stage, position = 0.000000 10:18:17 Stage Position Measurement, pos = 0.0000400 m 10:18:18 Magnet Current for Main, Imag = 0.4968 A Vtrans = 0.099289 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:19 Magnet Current for Main, Imag = 0.4968 A Vtrans = 0.099290 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:20 Magnet Current for Main, Imag = 0.4967 A Vtrans = 0.099288 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:20 Magnet Current for Main, Imag = 0.4967 A Vtrans = 0.099288 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:20 Magnet Avgerage Current Measurement for Main : Imag = 0.4968 +- 0.0000 A 10:18:21 Magnet Current for Main, Imag = 0.4967 A Vtrans = 0.099288 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:22 Main Volt Voltage Measurement, V = 1.096120 V 10:18:22 Temperature Measurement, Probe Number = 0, T = 30.200000 C 10:18:26 Temperature Measurement, Probe Number = 1, T = 30.160000 C 10:18:26 Temperature Measurement, Probe Number = 2, T = 27.650000 C 10:18:27 Temperature Measurement, Probe Number = 3, T = 28.138000 C 10:18:28 Temperature Measurement, Probe Number = 4, T = 29.563000 C 10:18:28 Temperature Measurement, Probe Number = 5, T = 23.598000 C 10:18:28 Magnet Test Parameter Measurements P0 = Main, Value = 0.50 P1 = Main Volt, Value = 1.10 P2 = RTD Inside, Value = 30.20 P3 = RTD Outside, Value = 30.16 P4 = Supply Water, Value = 27.65 P5 = Return Water, Value = 28.14 P6 = @ RTD Outside, Value = 29.56 P7 = Ambient, Value = 23.60 10:18:28 3 Axis Hall Probe Field Measurement, Bx = -0.000030, By = 0.000040, Bz = -0.004700 T 10:18:34 Move Stage, position = 0.000000 10:18:34 Magnet system Main current ramping to 1.0000 A... 10:18:51 Move Stage, position = 0.000000 10:18:53 Stage Position Measurement, pos = 0.0000400 m 10:18:53 Magnet Current for Main, Imag = 0.9969 A Vtrans = 0.199315 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:54 Magnet Current for Main, Imag = 0.9969 A Vtrans = 0.199317 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:55 Magnet Current for Main, Imag = 0.9969 A Vtrans = 0.199317 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:56 Magnet Current for Main, Imag = 0.9969 A Vtrans = 0.199316 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:56 Magnet Avgerage Current Measurement for Main : Imag = 0.9969 +- 0.0000 A 10:18:56 Magnet Current for Main, Imag = 0.9969 A Vtrans = 0.199315 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:18:57 Main Volt Voltage Measurement, V = 2.197930 V 10:18:57 Temperature Measurement, Probe Number = 0, T = 30.108000 C 10:19:01 Temperature Measurement, Probe Number = 1, T = 30.048000 C 10:19:02 Temperature Measurement, Probe Number = 2, T = 27.697000 C 10:19:02 Temperature Measurement, Probe Number = 3, T = 28.165000 C 10:19:03 Temperature Measurement, Probe Number = 4, T = 29.458000 C 10:19:03 Temperature Measurement, Probe Number = 5, T = 23.737000 C 10:19:03 Magnet Test Parameter Measurements P0 = Main, Value = 1.00 P1 = Main Volt, Value = 2.20 P2 = RTD Inside, Value = 30.11 P3 = RTD Outside, Value = 30.05 P4 = Supply Water, Value = 27.70 P5 = Return Water, Value = 28.16 P6 = @ RTD Outside, Value = 29.46 P7 = Ambient, Value = 23.74 10:19:03 3 Axis Hall Probe Field Measurement, Bx = -0.000050, By = 0.000040, Bz = -0.009410 T 10:19:10 Move Stage, position = 0.000000 10:19:10 Magnet system Main current ramping to 1.5000 A... 10:19:26 Move Stage, position = 0.000000 10:19:28 Stage Position Measurement, pos = 0.0000400 m 10:19:29 Magnet Current for Main, Imag = 1.4998 A Vtrans = 0.299894 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:19:29 Magnet Current for Main, Imag = 1.4998 A Vtrans = 0.299891 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:19:30 Magnet Current for Main, Imag = 1.4998 A Vtrans = 0.299895 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:19:31 Magnet Current for Main, Imag = 1.4998 A Vtrans = 0.299892 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:19:31 Magnet Avgerage Current Measurement for Main : Imag = 1.4998 +- 0.0000 A 10:19:31 Magnet Current for Main, Imag = 1.4998 A Vtrans = 0.299892 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:19:32 Main Volt Voltage Measurement, V = 3.304463 V 10:19:33 Temperature Measurement, Probe Number = 0, T = 30.034000 C 10:19:36 Temperature Measurement, Probe Number = 1, T = 29.947000 C 10:19:37 Temperature Measurement, Probe Number = 2, T = 27.697000 C 10:19:37 Temperature Measurement, Probe Number = 3, T = 28.204000 C 10:19:38 Temperature Measurement, Probe Number = 4, T = 29.364000 C 10:19:39 Temperature Measurement, Probe Number = 5, T = 23.806000 C 10:19:39 Magnet Test Parameter Measurements P0 = Main, Value = 1.50 P1 = Main Volt, Value = 3.30 P2 = RTD Inside, Value = 30.03 P3 = RTD Outside, Value = 29.95 P4 = Supply Water, Value = 27.70 P5 = Return Water, Value = 28.20 P6 = @ RTD Outside, Value = 29.36 P7 = Ambient, Value = 23.81 10:19:39 3 Axis Hall Probe Field Measurement, Bx = -0.000090, By = 0.000070, Bz = -0.014150 T 10:19:45 Move Stage, position = 0.000000 10:19:45 Magnet system Main current ramping to 2.0000 A... 10:20:01 Move Stage, position = 0.000000 10:20:03 Stage Position Measurement, pos = 0.0000400 m 10:20:04 Magnet Current for Main, Imag = 1.9973 A Vtrans = 0.399392 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:04 Magnet Current for Main, Imag = 1.9973 A Vtrans = 0.399390 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:05 Magnet Current for Main, Imag = 1.9973 A Vtrans = 0.399391 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:06 Magnet Current for Main, Imag = 1.9973 A Vtrans = 0.399393 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:06 Magnet Avgerage Current Measurement for Main : Imag = 1.9973 +- 0.0000 A 10:20:07 Magnet Current for Main, Imag = 1.9973 A Vtrans = 0.399390 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:07 Main Volt Voltage Measurement, V = 4.398340 V 10:20:08 Temperature Measurement, Probe Number = 0, T = 29.967000 C 10:20:11 Temperature Measurement, Probe Number = 1, T = 29.852000 C 10:20:12 Temperature Measurement, Probe Number = 2, T = 27.673000 C 10:20:13 Temperature Measurement, Probe Number = 3, T = 28.247000 C 10:20:13 Temperature Measurement, Probe Number = 4, T = 29.249000 C 10:20:14 Temperature Measurement, Probe Number = 5, T = 23.841000 C 10:20:14 Magnet Test Parameter Measurements P0 = Main, Value = 2.00 P1 = Main Volt, Value = 4.40 P2 = RTD Inside, Value = 29.97 P3 = RTD Outside, Value = 29.85 P4 = Supply Water, Value = 27.67 P5 = Return Water, Value = 28.25 P6 = @ RTD Outside, Value = 29.25 P7 = Ambient, Value = 23.84 10:20:14 3 Axis Hall Probe Field Measurement, Bx = -0.000130, By = 0.000090, Bz = -0.018850 T 10:20:20 Move Stage, position = 0.000000 10:20:20 Magnet system Main current ramping to 2.5000 A... 10:20:37 Move Stage, position = 0.000000 10:20:38 Stage Position Measurement, pos = 0.0000400 m 10:20:39 Magnet Current for Main, Imag = 2.4993 A Vtrans = 0.499794 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:40 Magnet Current for Main, Imag = 2.4993 A Vtrans = 0.499791 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:40 Magnet Current for Main, Imag = 2.4993 A Vtrans = 0.499792 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:41 Magnet Current for Main, Imag = 2.4993 A Vtrans = 0.499791 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:41 Magnet Avgerage Current Measurement for Main : Imag = 2.4993 +- 0.0000 A 10:20:42 Magnet Current for Main, Imag = 2.4993 A Vtrans = 0.499790 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:20:42 Main Volt Voltage Measurement, V = 5.501850 V 10:20:43 Temperature Measurement, Probe Number = 0, T = 29.920000 C 10:20:47 Temperature Measurement, Probe Number = 1, T = 29.795000 C 10:20:47 Temperature Measurement, Probe Number = 2, T = 27.660000 C 10:20:48 Temperature Measurement, Probe Number = 3, T = 28.232000 C 10:20:48 Temperature Measurement, Probe Number = 4, T = 29.199000 C 10:20:49 Temperature Measurement, Probe Number = 5, T = 23.882000 C 10:20:49 Magnet Test Parameter Measurements P0 = Main, Value = 2.50 P1 = Main Volt, Value = 5.50 P2 = RTD Inside, Value = 29.92 P3 = RTD Outside, Value = 29.80 P4 = Supply Water, Value = 27.66 P5 = Return Water, Value = 28.23 P6 = @ RTD Outside, Value = 29.20 P7 = Ambient, Value = 23.88 10:20:49 3 Axis Hall Probe Field Measurement, Bx = -0.000160, By = 0.000110, Bz = -0.023560 T 10:20:55 Move Stage, position = 0.000000 10:20:55 Magnet system Main current ramping to 3.0000 A... 10:21:12 Move Stage, position = 0.000000 10:21:13 Stage Position Measurement, pos = 0.0000400 m 10:21:14 Magnet Current for Main, Imag = 3.0013 A Vtrans = 0.600194 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:15 Magnet Current for Main, Imag = 3.0013 A Vtrans = 0.600195 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:15 Magnet Current for Main, Imag = 3.0013 A Vtrans = 0.600194 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:16 Magnet Current for Main, Imag = 3.0013 A Vtrans = 0.600195 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:16 Magnet Avgerage Current Measurement for Main : Imag = 3.0013 +- 0.0000 A 10:21:17 Magnet Current for Main, Imag = 3.0013 A Vtrans = 0.600195 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:17 Main Volt Voltage Measurement, V = 6.605767 V 10:21:18 Temperature Measurement, Probe Number = 0, T = 29.882000 C 10:21:22 Temperature Measurement, Probe Number = 1, T = 29.742000 C 10:21:22 Temperature Measurement, Probe Number = 2, T = 27.567000 C 10:21:23 Temperature Measurement, Probe Number = 3, T = 28.207000 C 10:21:23 Temperature Measurement, Probe Number = 4, T = 29.147000 C 10:21:24 Temperature Measurement, Probe Number = 5, T = 23.745000 C 10:21:24 Magnet Test Parameter Measurements P0 = Main, Value = 3.00 P1 = Main Volt, Value = 6.61 P2 = RTD Inside, Value = 29.88 P3 = RTD Outside, Value = 29.74 P4 = Supply Water, Value = 27.57 P5 = Return Water, Value = 28.21 P6 = @ RTD Outside, Value = 29.15 P7 = Ambient, Value = 23.75 10:21:24 3 Axis Hall Probe Field Measurement, Bx = -0.000200, By = 0.000130, Bz = -0.028310 T 10:21:30 Move Stage, position = 0.000000 10:21:30 Magnet system Main current ramping to 3.5000 A... 10:21:47 Move Stage, position = 0.000000 10:21:48 Stage Position Measurement, pos = 0.0000400 m 10:21:49 Magnet Current for Main, Imag = 3.4985 A Vtrans = 0.699632 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:50 Magnet Current for Main, Imag = 3.4985 A Vtrans = 0.699633 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:51 Magnet Current for Main, Imag = 3.4985 A Vtrans = 0.699632 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:51 Magnet Current for Main, Imag = 3.4985 A Vtrans = 0.699632 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:51 Magnet Avgerage Current Measurement for Main : Imag = 3.4985 +- 0.0000 A 10:21:52 Magnet Current for Main, Imag = 3.4985 A Vtrans = 0.699630 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:21:53 Main Volt Voltage Measurement, V = 7.700023 V 10:21:53 Temperature Measurement, Probe Number = 0, T = 29.858000 C 10:21:57 Temperature Measurement, Probe Number = 1, T = 29.714000 C 10:21:57 Temperature Measurement, Probe Number = 2, T = 27.536000 C 10:21:58 Temperature Measurement, Probe Number = 3, T = 28.198000 C 10:21:59 Temperature Measurement, Probe Number = 4, T = 29.124000 C 10:21:59 Temperature Measurement, Probe Number = 5, T = 23.702000 C 10:21:59 Magnet Test Parameter Measurements P0 = Main, Value = 3.50 P1 = Main Volt, Value = 7.70 P2 = RTD Inside, Value = 29.86 P3 = RTD Outside, Value = 29.71 P4 = Supply Water, Value = 27.54 P5 = Return Water, Value = 28.20 P6 = @ RTD Outside, Value = 29.12 P7 = Ambient, Value = 23.70 10:21:59 3 Axis Hall Probe Field Measurement, Bx = -0.000230, By = 0.000150, Bz = -0.032990 T 10:22:05 Move Stage, position = 0.000000 10:22:05 Magnet system Main current ramping to 4.0000 A... 10:22:22 Move Stage, position = 0.000000 10:22:24 Stage Position Measurement, pos = 0.0000400 m 10:22:24 Magnet Current for Main, Imag = 4.0001 A Vtrans = 0.799965 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:22:25 Magnet Current for Main, Imag = 4.0001 A Vtrans = 0.799967 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:22:26 Magnet Current for Main, Imag = 4.0001 A Vtrans = 0.799966 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:22:27 Magnet Current for Main, Imag = 4.0001 A Vtrans = 0.799967 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:22:27 Magnet Avgerage Current Measurement for Main : Imag = 4.0001 +- 0.0000 A 10:22:27 Magnet Current for Main, Imag = 4.0001 A Vtrans = 0.799967 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:22:28 Main Volt Voltage Measurement, V = 8.805765 V 10:22:28 Temperature Measurement, Probe Number = 0, T = 29.852000 C 10:22:32 Temperature Measurement, Probe Number = 1, T = 29.700000 C 10:22:33 Temperature Measurement, Probe Number = 2, T = 27.612000 C 10:22:33 Temperature Measurement, Probe Number = 3, T = 28.213000 C 10:22:34 Temperature Measurement, Probe Number = 4, T = 29.104000 C 10:22:34 Temperature Measurement, Probe Number = 5, T = 23.681000 C 10:22:34 Magnet Test Parameter Measurements P0 = Main, Value = 4.00 P1 = Main Volt, Value = 8.81 P2 = RTD Inside, Value = 29.85 P3 = RTD Outside, Value = 29.70 P4 = Supply Water, Value = 27.61 P5 = Return Water, Value = 28.21 P6 = @ RTD Outside, Value = 29.10 P7 = Ambient, Value = 23.68 10:22:34 3 Axis Hall Probe Field Measurement, Bx = -0.000270, By = 0.000170, Bz = -0.037710 T 10:22:41 Move Stage, position = 0.000000 10:22:41 Magnet system Main current ramping to 4.5000 A... 10:22:57 Move Stage, position = 0.000000 10:22:59 Stage Position Measurement, pos = 0.0000400 m 10:23:00 Magnet Current for Main, Imag = 4.4984 A Vtrans = 0.899628 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:00 Magnet Current for Main, Imag = 4.4984 A Vtrans = 0.899628 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:01 Magnet Current for Main, Imag = 4.4985 A Vtrans = 0.899629 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:02 Magnet Current for Main, Imag = 4.4985 A Vtrans = 0.899630 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:02 Magnet Avgerage Current Measurement for Main : Imag = 4.4985 +- 0.0000 A 10:23:02 Magnet Current for Main, Imag = 4.4984 A Vtrans = 0.899628 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:03 Main Volt Voltage Measurement, V = 9.906507 V 10:23:04 Temperature Measurement, Probe Number = 0, T = 29.860000 C 10:23:07 Temperature Measurement, Probe Number = 1, T = 29.710000 C 10:23:08 Temperature Measurement, Probe Number = 2, T = 27.732000 C 10:23:08 Temperature Measurement, Probe Number = 3, T = 28.234000 C 10:23:09 Temperature Measurement, Probe Number = 4, T = 29.102000 C 10:23:10 Temperature Measurement, Probe Number = 5, T = 23.781000 C 10:23:10 Magnet Test Parameter Measurements P0 = Main, Value = 4.50 P1 = Main Volt, Value = 9.91 P2 = RTD Inside, Value = 29.86 P3 = RTD Outside, Value = 29.71 P4 = Supply Water, Value = 27.73 P5 = Return Water, Value = 28.23 P6 = @ RTD Outside, Value = 29.10 P7 = Ambient, Value = 23.78 10:23:10 3 Axis Hall Probe Field Measurement, Bx = -0.000300, By = 0.000200, Bz = -0.042410 T 10:23:16 Move Stage, position = 0.000000 10:23:16 Magnet system Main current ramping to 5.0000 A... 10:23:32 Move Stage, position = 0.000000 10:23:34 Stage Position Measurement, pos = 0.0000400 m 10:23:35 Magnet Current for Main, Imag = 5.0007 A Vtrans = 1.000085 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:35 Magnet Current for Main, Imag = 5.0007 A Vtrans = 1.000085 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:36 Magnet Current for Main, Imag = 5.0007 A Vtrans = 1.000084 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:37 Magnet Current for Main, Imag = 5.0007 A Vtrans = 1.000083 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:37 Magnet Avgerage Current Measurement for Main : Imag = 5.0007 +- 0.0000 A 10:23:38 Magnet Current for Main, Imag = 5.0007 A Vtrans = 1.000084 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:23:38 Main Volt Voltage Measurement, V = 11.019072 V 10:23:39 Temperature Measurement, Probe Number = 0, T = 29.891000 C 10:23:42 Temperature Measurement, Probe Number = 1, T = 29.742000 C 10:23:43 Temperature Measurement, Probe Number = 2, T = 27.719000 C 10:23:44 Temperature Measurement, Probe Number = 3, T = 28.247000 C 10:23:44 Temperature Measurement, Probe Number = 4, T = 29.107000 C 10:23:45 Temperature Measurement, Probe Number = 5, T = 23.797000 C 10:23:45 Magnet Test Parameter Measurements P0 = Main, Value = 5.00 P1 = Main Volt, Value = 11.02 P2 = RTD Inside, Value = 29.89 P3 = RTD Outside, Value = 29.74 P4 = Supply Water, Value = 27.72 P5 = Return Water, Value = 28.25 P6 = @ RTD Outside, Value = 29.11 P7 = Ambient, Value = 23.80 10:23:45 3 Axis Hall Probe Field Measurement, Bx = -0.000340, By = 0.000210, Bz = -0.047130 T 10:23:51 Move Stage, position = 0.000000 10:23:51 Magnet system Main current ramping to 5.5000 A... 10:24:08 Move Stage, position = 0.000000 10:24:09 Stage Position Measurement, pos = 0.0000400 m 10:24:10 Magnet Current for Main, Imag = 5.5016 A Vtrans = 1.100252 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:11 Magnet Current for Main, Imag = 5.5016 A Vtrans = 1.100249 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:11 Magnet Current for Main, Imag = 5.5016 A Vtrans = 1.100250 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:12 Magnet Current for Main, Imag = 5.5016 A Vtrans = 1.100250 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:12 Magnet Avgerage Current Measurement for Main : Imag = 5.5016 +- 0.0000 A 10:24:13 Magnet Current for Main, Imag = 5.5015 A Vtrans = 1.100248 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:13 Main Volt Voltage Measurement, V = 12.132244 V 10:24:14 Temperature Measurement, Probe Number = 0, T = 29.943000 C 10:24:18 Temperature Measurement, Probe Number = 1, T = 29.801000 C 10:24:18 Temperature Measurement, Probe Number = 2, T = 27.747000 C 10:24:19 Temperature Measurement, Probe Number = 3, T = 28.262000 C 10:24:19 Temperature Measurement, Probe Number = 4, T = 29.142000 C 10:24:20 Temperature Measurement, Probe Number = 5, T = 23.868000 C 10:24:20 Magnet Test Parameter Measurements P0 = Main, Value = 5.50 P1 = Main Volt, Value = 12.13 P2 = RTD Inside, Value = 29.94 P3 = RTD Outside, Value = 29.80 P4 = Supply Water, Value = 27.75 P5 = Return Water, Value = 28.26 P6 = @ RTD Outside, Value = 29.14 P7 = Ambient, Value = 23.87 10:24:20 3 Axis Hall Probe Field Measurement, Bx = -0.000370, By = 0.000230, Bz = -0.051850 T 10:24:26 Move Stage, position = 0.000000 10:24:26 Magnet system Main current ramping to 6.0000 A... 10:24:43 Move Stage, position = 0.000000 10:24:44 Stage Position Measurement, pos = 0.0000400 m 10:24:45 Magnet Current for Main, Imag = 6.0033 A Vtrans = 1.200603 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:46 Magnet Current for Main, Imag = 6.0033 A Vtrans = 1.200605 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:46 Magnet Current for Main, Imag = 6.0033 A Vtrans = 1.200608 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:47 Magnet Current for Main, Imag = 6.0033 A Vtrans = 1.200605 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:47 Magnet Avgerage Current Measurement for Main : Imag = 6.0033 +- 0.0000 A 10:24:48 Magnet Current for Main, Imag = 6.0033 A Vtrans = 1.200605 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:24:48 Main Volt Voltage Measurement, V = 13.252297 V 10:24:49 Temperature Measurement, Probe Number = 0, T = 30.015000 C 10:24:53 Temperature Measurement, Probe Number = 1, T = 29.894000 C 10:24:53 Temperature Measurement, Probe Number = 2, T = 27.725000 C 10:24:54 Temperature Measurement, Probe Number = 3, T = 28.277000 C 10:24:54 Temperature Measurement, Probe Number = 4, T = 29.198000 C 10:24:55 Temperature Measurement, Probe Number = 5, T = 23.896000 C 10:24:55 Magnet Test Parameter Measurements P0 = Main, Value = 6.00 P1 = Main Volt, Value = 13.25 P2 = RTD Inside, Value = 30.02 P3 = RTD Outside, Value = 29.89 P4 = Supply Water, Value = 27.73 P5 = Return Water, Value = 28.28 P6 = @ RTD Outside, Value = 29.20 P7 = Ambient, Value = 23.90 10:24:55 3 Axis Hall Probe Field Measurement, Bx = -0.000400, By = 0.000250, Bz = -0.056570 T 10:25:01 Move Stage, position = 0.000000 10:25:01 Magnet system Main current ramping to 6.5000 A... 10:25:18 Move Stage, position = 0.000000 10:25:20 Stage Position Measurement, pos = 0.0000400 m 10:25:20 Magnet Current for Main, Imag = 6.4998 A Vtrans = 1.299902 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:21 Magnet Current for Main, Imag = 6.4998 A Vtrans = 1.299896 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:22 Magnet Current for Main, Imag = 6.4998 A Vtrans = 1.299895 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:22 Magnet Current for Main, Imag = 6.4998 A Vtrans = 1.299895 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:22 Magnet Avgerage Current Measurement for Main : Imag = 6.4998 +- 0.0000 A 10:25:23 Magnet Current for Main, Imag = 6.4998 A Vtrans = 1.299891 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:24 Main Volt Voltage Measurement, V = 14.365850 V 10:25:24 Temperature Measurement, Probe Number = 0, T = 30.110000 C 10:25:28 Temperature Measurement, Probe Number = 1, T = 30.004000 C 10:25:28 Temperature Measurement, Probe Number = 2, T = 27.630000 C 10:25:29 Temperature Measurement, Probe Number = 3, T = 28.279000 C 10:25:30 Temperature Measurement, Probe Number = 4, T = 29.275000 C 10:25:30 Temperature Measurement, Probe Number = 5, T = 23.807000 C 10:25:30 Magnet Test Parameter Measurements P0 = Main, Value = 6.50 P1 = Main Volt, Value = 14.37 P2 = RTD Inside, Value = 30.11 P3 = RTD Outside, Value = 30.00 P4 = Supply Water, Value = 27.63 P5 = Return Water, Value = 28.28 P6 = @ RTD Outside, Value = 29.27 P7 = Ambient, Value = 23.81 10:25:30 3 Axis Hall Probe Field Measurement, Bx = -0.000430, By = 0.000270, Bz = -0.061250 T 10:25:36 Move Stage, position = 0.000000 10:25:36 Magnet system Main current ramping to 7.0000 A... 10:25:53 Move Stage, position = 0.000000 10:25:55 Stage Position Measurement, pos = 0.0000400 m 10:25:55 Magnet Current for Main, Imag = 6.9952 A Vtrans = 1.398971 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:56 Magnet Current for Main, Imag = 6.9952 A Vtrans = 1.398970 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:57 Magnet Current for Main, Imag = 6.9952 A Vtrans = 1.398976 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:58 Magnet Current for Main, Imag = 6.9952 A Vtrans = 1.398971 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:58 Magnet Avgerage Current Measurement for Main : Imag = 6.9952 +- 0.0000 A 10:25:58 Magnet Current for Main, Imag = 6.9952 A Vtrans = 1.398974 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:25:59 Main Volt Voltage Measurement, V = 15.483433 V 10:25:59 Temperature Measurement, Probe Number = 0, T = 30.221000 C 10:26:03 Temperature Measurement, Probe Number = 1, T = 30.137000 C 10:26:04 Temperature Measurement, Probe Number = 2, T = 27.621000 C 10:26:04 Temperature Measurement, Probe Number = 3, T = 28.288000 C 10:26:05 Temperature Measurement, Probe Number = 4, T = 29.370000 C 10:26:05 Temperature Measurement, Probe Number = 5, T = 23.894000 C 10:26:05 Magnet Test Parameter Measurements P0 = Main, Value = 7.00 P1 = Main Volt, Value = 15.48 P2 = RTD Inside, Value = 30.22 P3 = RTD Outside, Value = 30.14 P4 = Supply Water, Value = 27.62 P5 = Return Water, Value = 28.29 P6 = @ RTD Outside, Value = 29.37 P7 = Ambient, Value = 23.89 10:26:05 3 Axis Hall Probe Field Measurement, Bx = -0.000470, By = 0.000290, Bz = -0.065900 T 10:26:12 Move Stage, position = 0.000000 10:26:12 Magnet system Main current ramping to 7.5000 A... 10:26:28 Move Stage, position = 0.000000 10:26:30 Stage Position Measurement, pos = 0.0000400 m 10:26:31 Magnet Current for Main, Imag = 7.5007 A Vtrans = 1.500073 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:26:31 Magnet Current for Main, Imag = 7.5007 A Vtrans = 1.500076 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:26:32 Magnet Current for Main, Imag = 7.5007 A Vtrans = 1.500076 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:26:33 Magnet Current for Main, Imag = 7.5007 A Vtrans = 1.500074 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:26:33 Magnet Avgerage Current Measurement for Main : Imag = 7.5007 +- 0.0000 A 10:26:33 Magnet Current for Main, Imag = 7.5007 A Vtrans = 1.500069 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:26:34 Main Volt Voltage Measurement, V = 16.630699 V 10:26:35 Temperature Measurement, Probe Number = 0, T = 30.367000 C 10:26:38 Temperature Measurement, Probe Number = 1, T = 30.300000 C 10:26:39 Temperature Measurement, Probe Number = 2, T = 27.659000 C 10:26:39 Temperature Measurement, Probe Number = 3, T = 28.320000 C 10:26:40 Temperature Measurement, Probe Number = 4, T = 29.486000 C 10:26:41 Temperature Measurement, Probe Number = 5, T = 24.011000 C 10:26:41 Magnet Test Parameter Measurements P0 = Main, Value = 7.50 P1 = Main Volt, Value = 16.63 P2 = RTD Inside, Value = 30.37 P3 = RTD Outside, Value = 30.30 P4 = Supply Water, Value = 27.66 P5 = Return Water, Value = 28.32 P6 = @ RTD Outside, Value = 29.49 P7 = Ambient, Value = 24.01 10:26:41 3 Axis Hall Probe Field Measurement, Bx = -0.000500, By = 0.000320, Bz = -0.070660 T 10:26:47 Move Stage, position = 0.000000 10:26:47 Magnet system Main current ramping to 8.0000 A... 10:27:03 Move Stage, position = 0.000000 10:27:05 Stage Position Measurement, pos = 0.0000400 m 10:27:06 Magnet Current for Main, Imag = 8.0007 A Vtrans = 1.600083 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:06 Magnet Current for Main, Imag = 8.0008 A Vtrans = 1.600089 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:07 Magnet Current for Main, Imag = 8.0007 A Vtrans = 1.600087 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:08 Magnet Current for Main, Imag = 8.0008 A Vtrans = 1.600091 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:08 Magnet Avgerage Current Measurement for Main : Imag = 8.0007 +- 0.0000 A 10:27:09 Magnet Current for Main, Imag = 8.0008 A Vtrans = 1.600093 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:09 Main Volt Voltage Measurement, V = 17.774151 V 10:27:10 Temperature Measurement, Probe Number = 0, T = 30.538000 C 10:27:13 Temperature Measurement, Probe Number = 1, T = 30.495000 C 10:27:14 Temperature Measurement, Probe Number = 2, T = 27.655000 C 10:27:15 Temperature Measurement, Probe Number = 3, T = 28.357000 C 10:27:15 Temperature Measurement, Probe Number = 4, T = 29.630000 C 10:27:16 Temperature Measurement, Probe Number = 5, T = 24.016000 C 10:27:16 Magnet Test Parameter Measurements P0 = Main, Value = 8.00 P1 = Main Volt, Value = 17.77 P2 = RTD Inside, Value = 30.54 P3 = RTD Outside, Value = 30.50 P4 = Supply Water, Value = 27.66 P5 = Return Water, Value = 28.36 P6 = @ RTD Outside, Value = 29.63 P7 = Ambient, Value = 24.02 10:27:16 3 Axis Hall Probe Field Measurement, Bx = -0.000540, By = 0.000340, Bz = -0.075360 T 10:27:22 Move Stage, position = 0.000000 10:27:22 Magnet system Main current ramping to 8.5000 A... 10:27:39 Move Stage, position = 0.000000 10:27:40 Stage Position Measurement, pos = 0.0000400 m 10:27:41 Magnet Current for Main, Imag = 8.4998 A Vtrans = 1.699892 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:42 Magnet Current for Main, Imag = 8.4998 A Vtrans = 1.699896 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:42 Magnet Current for Main, Imag = 8.4998 A Vtrans = 1.699899 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:43 Magnet Current for Main, Imag = 8.4998 A Vtrans = 1.699891 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:43 Magnet Avgerage Current Measurement for Main : Imag = 8.4998 +- 0.0000 A 10:27:44 Magnet Current for Main, Imag = 8.4998 A Vtrans = 1.699894 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:27:44 Main Volt Voltage Measurement, V = 18.923975 V 10:27:45 Temperature Measurement, Probe Number = 0, T = 30.726000 C 10:27:49 Temperature Measurement, Probe Number = 1, T = 30.720000 C 10:27:49 Temperature Measurement, Probe Number = 2, T = 27.640000 C 10:27:50 Temperature Measurement, Probe Number = 3, T = 28.365000 C 10:27:50 Temperature Measurement, Probe Number = 4, T = 29.803000 C 10:27:51 Temperature Measurement, Probe Number = 5, T = 23.940000 C 10:27:51 Magnet Test Parameter Measurements P0 = Main, Value = 8.50 P1 = Main Volt, Value = 18.92 P2 = RTD Inside, Value = 30.73 P3 = RTD Outside, Value = 30.72 P4 = Supply Water, Value = 27.64 P5 = Return Water, Value = 28.36 P6 = @ RTD Outside, Value = 29.80 P7 = Ambient, Value = 23.94 10:27:51 3 Axis Hall Probe Field Measurement, Bx = -0.000570, By = 0.000340, Bz = -0.080060 T 10:27:57 Move Stage, position = 0.000000 10:27:57 Magnet system Main current ramping to 9.0000 A... 10:28:14 Move Stage, position = 0.000000 10:28:15 Stage Position Measurement, pos = 0.0000400 m 10:28:16 Magnet Current for Main, Imag = 8.9988 A Vtrans = 1.799702 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:17 Magnet Current for Main, Imag = 8.9988 A Vtrans = 1.799699 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:17 Magnet Current for Main, Imag = 8.9988 A Vtrans = 1.799703 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:18 Magnet Current for Main, Imag = 8.9988 A Vtrans = 1.799703 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:18 Magnet Avgerage Current Measurement for Main : Imag = 8.9988 +- 0.0000 A 10:28:19 Magnet Current for Main, Imag = 8.9988 A Vtrans = 1.799700 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:19 Main Volt Voltage Measurement, V = 20.083653 V 10:28:20 Temperature Measurement, Probe Number = 0, T = 30.939000 C 10:28:24 Temperature Measurement, Probe Number = 1, T = 30.977000 C 10:28:24 Temperature Measurement, Probe Number = 2, T = 27.639000 C 10:28:25 Temperature Measurement, Probe Number = 3, T = 28.404000 C 10:28:25 Temperature Measurement, Probe Number = 4, T = 30.007000 C 10:28:26 Temperature Measurement, Probe Number = 5, T = 23.953000 C 10:28:26 Magnet Test Parameter Measurements P0 = Main, Value = 9.00 P1 = Main Volt, Value = 20.08 P2 = RTD Inside, Value = 30.94 P3 = RTD Outside, Value = 30.98 P4 = Supply Water, Value = 27.64 P5 = Return Water, Value = 28.40 P6 = @ RTD Outside, Value = 30.01 P7 = Ambient, Value = 23.95 10:28:26 3 Axis Hall Probe Field Measurement, Bx = -0.000600, By = 0.000370, Bz = -0.084750 T 10:28:32 Move Stage, position = 0.000000 10:28:32 Magnet system Main current ramping to 9.5000 A... 10:28:49 Move Stage, position = 0.000000 10:28:51 Stage Position Measurement, pos = 0.0000400 m 10:28:51 Magnet Current for Main, Imag = 9.5024 A Vtrans = 1.900424 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:52 Magnet Current for Main, Imag = 9.5024 A Vtrans = 1.900420 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:53 Magnet Current for Main, Imag = 9.5024 A Vtrans = 1.900422 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:54 Magnet Current for Main, Imag = 9.5024 A Vtrans = 1.900425 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:54 Magnet Avgerage Current Measurement for Main : Imag = 9.5024 +- 0.0000 A 10:28:54 Magnet Current for Main, Imag = 9.5024 A Vtrans = 1.900420 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:28:55 Main Volt Voltage Measurement, V = 21.264484 V 10:28:55 Temperature Measurement, Probe Number = 0, T = 31.175000 C 10:28:59 Temperature Measurement, Probe Number = 1, T = 31.252000 C 10:29:00 Temperature Measurement, Probe Number = 2, T = 27.518000 C 10:29:00 Temperature Measurement, Probe Number = 3, T = 28.406000 C 10:29:01 Temperature Measurement, Probe Number = 4, T = 30.226000 C 10:29:02 Temperature Measurement, Probe Number = 5, T = 23.860000 C 10:29:02 Magnet Test Parameter Measurements P0 = Main, Value = 9.50 P1 = Main Volt, Value = 21.26 P2 = RTD Inside, Value = 31.18 P3 = RTD Outside, Value = 31.25 P4 = Supply Water, Value = 27.52 P5 = Return Water, Value = 28.41 P6 = @ RTD Outside, Value = 30.23 P7 = Ambient, Value = 23.86 10:29:02 3 Axis Hall Probe Field Measurement, Bx = -0.000630, By = 0.000390, Bz = -0.089490 T 10:29:08 Move Stage, position = 0.000000 10:29:08 Magnet system Main current ramping to 10.0000 A... 10:29:24 Move Stage, position = 0.000000 10:29:26 Stage Position Measurement, pos = 0.0000400 m 10:29:27 Magnet Current for Main, Imag = 10.0007 A Vtrans = 2.000083 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:29:27 Magnet Current for Main, Imag = 10.0007 A Vtrans = 2.000081 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:29:28 Magnet Current for Main, Imag = 10.0007 A Vtrans = 2.000080 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:29:29 Magnet Current for Main, Imag = 10.0008 A Vtrans = 2.000089 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:29:29 Magnet Avgerage Current Measurement for Main : Imag = 10.0007 +- 0.0000 A 10:29:30 Magnet Current for Main, Imag = 10.0007 A Vtrans = 2.000079 V, Factor V/A = 0.200000 V/A, Zero Current = -0.000307 A 10:29:30 Main Volt Voltage Measurement, V = 22.445606 V 10:29:31 Temperature Measurement, Probe Number = 0, T = 31.440000 C 10:29:34 Temperature Measurement, Probe Number = 1, T = 31.574000 C 10:29:35 Temperature Measurement, Probe Number = 2, T = 27.449000 C 10:29:36 Temperature Measurement, Probe Number = 3, T = 28.418000 C 10:29:36 Temperature Measurement, Probe Number = 4, T = 30.470000 C 10:29:37 Temperature Measurement, Probe Number = 5, T = 23.918000 C 10:29:37 Magnet Test Parameter Measurements P0 = Main, Value = 10.00 P1 = Main Volt, Value = 22.45 P2 = RTD Inside, Value = 31.44 P3 = RTD Outside, Value = 31.57 P4 = Supply Water, Value = 27.45 P5 = Return Water, Value = 28.42 P6 = @ RTD Outside, Value = 30.47 P7 = Ambient, Value = 23.92 10:29:37 3 Axis Hall Probe Field Measurement, Bx = -0.000670, By = 0.000410, Bz = -0.094180 T 10:29:43 Move Stage, position = 0.000000 10:29:44 Magnet system Main current ramping to 0.0000 A...