SLAC Magnetic Measurements Date: 07-14-2017 Time: 13:32:27 Project: LCLS-II Magnet Type: Solenoid Magnet Name: 4051 Serial Number: Run Number: 6 Measurement Device: Coil_1 Operator: sda Comment: Bn at z = 0. Solenoid at 0 A, Quad trims individually at +2 A. Test no error check Standardization for Main: 2 cycles from -10.0 A to 10.0 A to -10.0 A Test Currents for Main (A): 0.00 0.00 Test Currents for NM_QUAD (A): 2.00 0.00 Test Currents for SK_QUAD (A): 0.00 2.00 Field Harmonics vs Z Harmonics given at coil radius R = 0.012120 m Z B1 THsp1 B2 THsp2 B3 THsp3 B4 THsp4 Main +/- sigma NM_QUAD +/- sigma SK_QUAD +/- sigma # (m) (G) (deg) (G) (deg) (G) (deg) (G) (deg) (A) (A) (A) --- -------- --------- --------- --------- --------- --------- --------- --------- --------- ------------+----------- ------------+----------- ------------+----------- 1 0.0000 0.07 -165.67 1.42 57.38 0.03 -9.01 0.04 -17.78 -0.0020 0.0000 2.0009 0.0000 -0.0012 0.0000 Field Harmonics vs Z Harmonics given at coil radius R = 0.012120 m Z B1 THsp1 B2 THsp2 B3 THsp3 B4 THsp4 Main +/- sigma NM_QUAD +/- sigma SK_QUAD +/- sigma # (m) (G) (deg) (G) (deg) (G) (deg) (G) (deg) (A) (A) (A) --- -------- --------- --------- --------- --------- --------- --------- --------- --------- ------------+----------- ------------+----------- ------------+----------- 1 0.0000 0.24 -151.09 1.39 8.78 0.05 3.55 0.05 -17.69 -0.0020 0.0000 -0.0008 0.0000 2.0003 0.0000