SLAC Magnetic Measurements Date: 02-15-2018 Time: 18:07:29 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 88 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=1.3 s Coil attached with tape. Offset corr: TRUE 18:07:29 Ambient Measurement Device(s) Being Used, type = None 18:07:29 Magnet Voltage Measurement Device(s) Being Used, type = None 18:07:29 Temperature Measurement Device(s) Being Used, type = None 18:07:30 XMAG Device(s) Being Used, type = None 18:07:30 Ambient Measurement Device(s) Being Used, type = None 18:07:33 Magnet Test Parameter Measurements 18:07:33 Integrated Voltage Measurement... 18:07:50 Voltage Offset Correction: v_off_ini = -0.000005991 V, v_off_fin = 0.000060016 V 18:07:50 Integrated Voltage Measurement Delta Gap = 0.0039000 m VT = -0.171026600 Vs 18:07:50 Integrated Voltage Measurement... 18:08:06 Voltage Offset Correction: v_off_ini = -0.000006990 V, v_off_fin = 0.000051709 V 18:08:06 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171632404 Vs 18:08:08 Magnet Test Parameter Measurements 18:08:08 Integrated Voltage Measurement... 18:08:24 Voltage Offset Correction: v_off_ini = -0.000004319 V, v_off_fin = 0.000061152 V 18:08:24 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171042031 Vs 18:08:24 Integrated Voltage Measurement... 18:08:40 Voltage Offset Correction: v_off_ini = -0.000005659 V, v_off_fin = 0.000045252 V 18:08:40 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171674355 Vs 18:08:42 Magnet Test Parameter Measurements 18:08:42 Integrated Voltage Measurement... 18:08:58 Voltage Offset Correction: v_off_ini = -0.000003023 V, v_off_fin = 0.000057985 V 18:08:58 Integrated Voltage Measurement Delta Gap = 0.0039002 m VT = -0.171030932 Vs 18:08:58 Integrated Voltage Measurement... 18:09:14 Voltage Offset Correction: v_off_ini = -0.000006317 V, v_off_fin = 0.000049102 V 18:09:14 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171651315 Vs 18:09:16 Magnet Test Parameter Measurements 18:09:16 Integrated Voltage Measurement... 18:09:32 Voltage Offset Correction: v_off_ini = -0.000005398 V, v_off_fin = 0.000063990 V 18:09:32 Integrated Voltage Measurement Delta Gap = 0.0039002 m VT = -0.171033308 Vs 18:09:32 Integrated Voltage Measurement... 18:09:47 Voltage Offset Correction: v_off_ini = -0.000007136 V, v_off_fin = 0.000048603 V 18:09:47 Integrated Voltage Measurement Delta Gap = -0.0039002 m VT = 0.171657465 Vs 18:09:49 Magnet Test Parameter Measurements 18:09:49 Integrated Voltage Measurement... 18:10:05 Voltage Offset Correction: v_off_ini = -0.000004938 V, v_off_fin = 0.000068970 V 18:10:05 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171067756 Vs 18:10:05 Integrated Voltage Measurement... 18:10:21 Voltage Offset Correction: v_off_ini = -0.000006391 V, v_off_fin = 0.000051038 V 18:10:21 Integrated Voltage Measurement Delta Gap = -0.0039002 m VT = 0.171648475 Vs 18:10:23 Magnet Test Parameter Measurements 18:10:23 Integrated Voltage Measurement... 18:10:38 Voltage Offset Correction: v_off_ini = -0.000006437 V, v_off_fin = 0.000082625 V 18:10:38 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171140649 Vs 18:10:38 Integrated Voltage Measurement... 18:10:54 Voltage Offset Correction: v_off_ini = -0.000007286 V, v_off_fin = 0.000056104 V 18:10:54 Integrated Voltage Measurement Delta Gap = -0.0039002 m VT = 0.171619436 Vs 18:10:56 Magnet Test Parameter Measurements 18:10:56 Integrated Voltage Measurement... 18:11:12 Voltage Offset Correction: v_off_ini = -0.000004732 V, v_off_fin = 0.000070332 V 18:11:12 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171068317 Vs 18:11:12 Integrated Voltage Measurement... 18:11:28 Voltage Offset Correction: v_off_ini = -0.000007370 V, v_off_fin = 0.000050378 V 18:11:28 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171647315 Vs 18:11:30 Magnet Test Parameter Measurements 18:11:30 Integrated Voltage Measurement... 18:11:46 Voltage Offset Correction: v_off_ini = -0.000002485 V, v_off_fin = 0.000097300 V 18:11:46 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171238166 Vs 18:11:46 Integrated Voltage Measurement... 18:12:02 Voltage Offset Correction: v_off_ini = -0.000007216 V, v_off_fin = 0.000051378 V 18:12:02 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171651977 Vs 18:12:04 Magnet Test Parameter Measurements 18:12:04 Integrated Voltage Measurement... 18:12:19 Voltage Offset Correction: v_off_ini = -0.000003176 V, v_off_fin = 0.000079817 V 18:12:19 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171131511 Vs 18:12:20 Integrated Voltage Measurement... 18:12:35 Voltage Offset Correction: v_off_ini = -0.000005830 V, v_off_fin = 0.000054701 V 18:12:35 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171614415 Vs 18:12:37 Magnet Test Parameter Measurements 18:12:37 Integrated Voltage Measurement... 18:12:53 Voltage Offset Correction: v_off_ini = -0.000005380 V, v_off_fin = 0.000071587 V 18:12:53 Integrated Voltage Measurement Delta Gap = 0.0039003 m VT = -0.171066250 Vs 18:12:53 Integrated Voltage Measurement... 18:13:08 Voltage Offset Correction: v_off_ini = -0.000006742 V, v_off_fin = 0.000057944 V 18:13:08 Integrated Voltage Measurement Delta Gap = -0.0039001 m VT = 0.171610420 Vs