SLAC Magnetic Measurements Date: 02-15-2018 Time: 17:24:22 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 84 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=1.3 s Coil attached with tape. Offset corr: TRUE 17:24:22 Ambient Measurement Device(s) Being Used, type = None 17:24:22 Magnet Voltage Measurement Device(s) Being Used, type = None 17:24:22 Temperature Measurement Device(s) Being Used, type = None 17:24:22 XMAG Device(s) Being Used, type = None 17:24:22 Ambient Measurement Device(s) Being Used, type = None 17:24:26 Magnet Test Parameter Measurements 17:24:26 Integrated Voltage Measurement... 17:24:44 Voltage Offset Correction: v_off_ini = -0.000005453 V, v_off_fin = 0.000055021 V 17:24:45 Integrated Voltage Measurement Delta Gap = 0.0043000 m VT = -0.182766115 Vs 17:24:45 Integrated Voltage Measurement... 17:25:01 Voltage Offset Correction: v_off_ini = -0.000006454 V, v_off_fin = 0.000053656 V 17:25:01 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183354721 Vs 17:25:03 Magnet Test Parameter Measurements 17:25:04 Integrated Voltage Measurement... 17:25:20 Voltage Offset Correction: v_off_ini = -0.000007756 V, v_off_fin = 0.000059380 V 17:25:20 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182793684 Vs 17:25:20 Integrated Voltage Measurement... 17:25:37 Voltage Offset Correction: v_off_ini = -0.000005566 V, v_off_fin = 0.000050088 V 17:25:37 Integrated Voltage Measurement Delta Gap = -0.0043002 m VT = 0.183394718 Vs 17:25:39 Magnet Test Parameter Measurements 17:25:39 Integrated Voltage Measurement... 17:25:55 Voltage Offset Correction: v_off_ini = -0.000004921 V, v_off_fin = 0.000066544 V 17:25:56 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182859037 Vs 17:25:56 Integrated Voltage Measurement... 17:26:12 Voltage Offset Correction: v_off_ini = -0.000007970 V, v_off_fin = 0.000045963 V 17:26:12 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183443247 Vs 17:26:14 Magnet Test Parameter Measurements 17:26:15 Integrated Voltage Measurement... 17:26:31 Voltage Offset Correction: v_off_ini = -0.000004356 V, v_off_fin = 0.000066930 V 17:26:32 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182859795 Vs 17:26:32 Integrated Voltage Measurement... 17:26:48 Voltage Offset Correction: v_off_ini = -0.000005030 V, v_off_fin = 0.000049703 V 17:26:48 Integrated Voltage Measurement Delta Gap = -0.0043002 m VT = 0.183401817 Vs 17:26:51 Magnet Test Parameter Measurements 17:26:51 Integrated Voltage Measurement... 17:27:08 Voltage Offset Correction: v_off_ini = -0.000003727 V, v_off_fin = 0.000055893 V 17:27:08 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182794667 Vs 17:27:08 Integrated Voltage Measurement... 17:27:24 Voltage Offset Correction: v_off_ini = -0.000008606 V, v_off_fin = 0.000043723 V 17:27:24 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183474299 Vs 17:27:26 Magnet Test Parameter Measurements 17:27:27 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = -0.000000842 V, v_off_fin = 0.000078054 V 17:27:43 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182955775 Vs 17:27:43 Integrated Voltage Measurement... 17:28:00 Voltage Offset Correction: v_off_ini = -0.000004075 V, v_off_fin = 0.000050400 V 17:28:00 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183399597 Vs 17:28:02 Magnet Test Parameter Measurements 17:28:02 Integrated Voltage Measurement... 17:28:19 Voltage Offset Correction: v_off_ini = -0.000002701 V, v_off_fin = 0.000081915 V 17:28:19 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182963303 Vs 17:28:19 Integrated Voltage Measurement... 17:28:36 Voltage Offset Correction: v_off_ini = -0.000004510 V, v_off_fin = 0.000058471 V 17:28:36 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183351340 Vs 17:28:38 Magnet Test Parameter Measurements 17:28:38 Integrated Voltage Measurement... 17:28:55 Voltage Offset Correction: v_off_ini = -0.000009082 V, v_off_fin = 0.000060277 V 17:28:55 Integrated Voltage Measurement Delta Gap = 0.0043002 m VT = -0.182774695 Vs 17:28:55 Integrated Voltage Measurement... 17:29:12 Voltage Offset Correction: v_off_ini = -0.000006899 V, v_off_fin = 0.000053537 V 17:29:12 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183393327 Vs 17:29:15 Magnet Test Parameter Measurements 17:29:15 Integrated Voltage Measurement... 17:29:31 Voltage Offset Correction: v_off_ini = -0.000002823 V, v_off_fin = 0.000061082 V 17:29:31 Integrated Voltage Measurement Delta Gap = 0.0043003 m VT = -0.182818972 Vs 17:29:31 Integrated Voltage Measurement... 17:29:48 Voltage Offset Correction: v_off_ini = -0.000009754 V, v_off_fin = 0.000056971 V 17:29:48 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183404996 Vs 17:29:50 Magnet Test Parameter Measurements 17:29:50 Integrated Voltage Measurement... 17:30:07 Voltage Offset Correction: v_off_ini = -0.000001692 V, v_off_fin = 0.000076772 V 17:30:07 Integrated Voltage Measurement Delta Gap = 0.0043002 m VT = -0.182925215 Vs 17:30:07 Integrated Voltage Measurement... 17:30:24 Voltage Offset Correction: v_off_ini = -0.000008232 V, v_off_fin = 0.000056957 V 17:30:24 Integrated Voltage Measurement Delta Gap = -0.0043001 m VT = 0.183391931 Vs