SLAC Magnetic Measurements Date: 02-15-2018 Time: 21:37:34 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 112 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=3.0 s Coil attached with tape. Offset corr: TRUE Samples offset corr.: 20 21:37:34 Ambient Measurement Device(s) Being Used, type = None 21:37:34 Magnet Voltage Measurement Device(s) Being Used, type = None 21:37:34 Temperature Measurement Device(s) Being Used, type = None 21:37:34 XMAG Device(s) Being Used, type = None 21:37:34 Ambient Measurement Device(s) Being Used, type = None 21:37:36 Magnet Test Parameter Measurements 21:37:36 Integrated Voltage Measurement... 21:37:50 Voltage Offset Correction: v_off_ini = -0.000004378 V, v_off_fin = -0.000005821 V 21:37:50 Integrated Voltage Measurement Delta Gap = 0.0020008 m VT = -0.099765290 Vs 21:37:50 Integrated Voltage Measurement... 21:38:02 Voltage Offset Correction: v_off_ini = -0.000005096 V, v_off_fin = -0.000001249 V 21:38:02 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100670154 Vs 21:38:05 Magnet Test Parameter Measurements 21:38:05 Integrated Voltage Measurement... 21:38:17 Voltage Offset Correction: v_off_ini = -0.000004469 V, v_off_fin = -0.000007008 V 21:38:17 Integrated Voltage Measurement Delta Gap = 0.0020002 m VT = -0.099734679 Vs 21:38:17 Integrated Voltage Measurement... 21:38:30 Voltage Offset Correction: v_off_ini = -0.000005251 V, v_off_fin = -0.000002438 V 21:38:30 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100679079 Vs 21:38:32 Magnet Test Parameter Measurements 21:38:32 Integrated Voltage Measurement... 21:38:44 Voltage Offset Correction: v_off_ini = -0.000004157 V, v_off_fin = -0.000006756 V 21:38:44 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099730941 Vs 21:38:45 Integrated Voltage Measurement... 21:38:57 Voltage Offset Correction: v_off_ini = -0.000004650 V, v_off_fin = -0.000002485 V 21:38:57 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100656827 Vs 21:38:59 Magnet Test Parameter Measurements 21:38:59 Integrated Voltage Measurement... 21:39:11 Voltage Offset Correction: v_off_ini = -0.000004215 V, v_off_fin = -0.000005609 V 21:39:11 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099744770 Vs 21:39:12 Integrated Voltage Measurement... 21:39:24 Voltage Offset Correction: v_off_ini = -0.000006033 V, v_off_fin = -0.000002596 V 21:39:24 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100659629 Vs 21:39:26 Magnet Test Parameter Measurements 21:39:26 Integrated Voltage Measurement... 21:39:38 Voltage Offset Correction: v_off_ini = -0.000004277 V, v_off_fin = -0.000006593 V 21:39:39 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099730623 Vs 21:39:39 Integrated Voltage Measurement... 21:39:51 Voltage Offset Correction: v_off_ini = -0.000005090 V, v_off_fin = -0.000002487 V 21:39:51 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100667494 Vs 21:39:53 Magnet Test Parameter Measurements 21:39:53 Integrated Voltage Measurement... 21:40:05 Voltage Offset Correction: v_off_ini = -0.000003767 V, v_off_fin = -0.000005781 V 21:40:06 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099746257 Vs 21:40:06 Integrated Voltage Measurement... 21:40:18 Voltage Offset Correction: v_off_ini = -0.000005909 V, v_off_fin = -0.000000991 V 21:40:18 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100658025 Vs 21:40:20 Magnet Test Parameter Measurements 21:40:20 Integrated Voltage Measurement... 21:40:33 Voltage Offset Correction: v_off_ini = -0.000003757 V, v_off_fin = -0.000006673 V 21:40:33 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099740667 Vs 21:40:33 Integrated Voltage Measurement... 21:40:45 Voltage Offset Correction: v_off_ini = -0.000006166 V, v_off_fin = -0.000001957 V 21:40:45 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100660015 Vs 21:40:47 Magnet Test Parameter Measurements 21:40:47 Integrated Voltage Measurement... 21:41:00 Voltage Offset Correction: v_off_ini = -0.000003647 V, v_off_fin = -0.000006177 V 21:41:00 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099736947 Vs 21:41:00 Integrated Voltage Measurement... 21:41:12 Voltage Offset Correction: v_off_ini = -0.000005082 V, v_off_fin = -0.000002759 V 21:41:12 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100656719 Vs 21:41:14 Magnet Test Parameter Measurements 21:41:14 Integrated Voltage Measurement... 21:41:27 Voltage Offset Correction: v_off_ini = -0.000003532 V, v_off_fin = -0.000004273 V 21:41:27 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099750326 Vs 21:41:27 Integrated Voltage Measurement... 21:41:39 Voltage Offset Correction: v_off_ini = -0.000005565 V, v_off_fin = -0.000001883 V 21:41:39 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100656328 Vs 21:41:41 Magnet Test Parameter Measurements 21:41:41 Integrated Voltage Measurement... 21:41:55 Voltage Offset Correction: v_off_ini = -0.000003727 V, v_off_fin = 0.000058904 V 21:41:55 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099980678 Vs 21:41:55 Integrated Voltage Measurement... 21:42:07 Voltage Offset Correction: v_off_ini = -0.000005042 V, v_off_fin = -0.000001726 V 21:42:07 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100646909 Vs