SLAC Magnetic Measurements Date: 01-28-2026 Time: 15:22:41 Project: LCLS-II Magnet Type: Quad Magnet Name: 4210 Serial Number: Run Number: 9 Measurement Device: Thermistor Operator: sda Comment: Full Magnet Flow Test Measurement at 115 delta pressure Resistance, Temperature and Flow Measurements T0 = Ambient W0 = Supply Temp(C) W1 = Return Temp(C) W2 = Supply Pres(psi) W3 = Return Pres(psi) W4 = Flow Rate(gpm) Time Main Main T0 W0 W1 W2 W3 W4 (A) (mohm) (deg C) --------- ------------ --------- --------- --------- --------- --------- --------- --------- 15:23:02 0.000 0.000 19.05 21.75 20.60 125.78 11.12 0.58 15:23:21 0.000 0.000 19.05 21.74 20.59 124.89 11.12 0.56 15:23:41 -0.000 0.000 19.06 21.73 20.59 125.39 11.13 0.60 15:24:01 0.000 0.000 19.08 21.73 20.60 124.64 11.13 0.58 15:24:21 -0.000 0.000 19.10 21.73 20.60 124.39 11.13 0.57 15:24:41 -0.000 0.000 19.11 21.73 20.60 124.31 11.12 0.56 15:25:01 -0.000 0.000 19.13 21.74 20.61 124.27 11.13 0.58 15:25:21 -0.000 0.000 19.14 21.75 20.62 126.27 11.12 0.58 15:25:41 0.000 0.000 19.14 21.77 20.63 125.28 11.12 0.57 15:26:01 0.000 0.000 19.14 21.79 20.65 124.17 11.13 0.57 15:26:21 -0.001 0.000 19.14 21.81 20.67 124.97 11.13 0.55 15:26:41 -0.000 0.000 19.16 21.84 20.70 123.68 11.13 0.59