Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0947 262.7579 2.5547 1.5710 1.4135 7 333.0967 262.7597 2.5562 1.3535 1.2267 Mean 333.0957 262.7588 2.5554 1.4622 1.3201 Std 0.0014 0.0012 0.0011 0.1538 0.1321 Error 0.00382 0.00168 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -8.7669 3.3574 1.6077 32.2068 11.3692 4.0124 7 -7.3170 3.9974 4.4877 34.6668 13.3214 5.7500 Mean -8.0419 3.6774 3.0477 33.4368 12.3453 4.8812 Std 1.0253 0.4526 2.0365 1.7395 1.3804 1.2287