SLAC Magnetic Measurements Date: 10-28-2020 Time: 18:59:31 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_022_Cell_40_Upstairs Serial Number: PC33408 Run Number: 5 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 5 18:59:49 Ambient Measurement Device(s) Being Used, type = None 18:59:49 Magnet Voltage Measurement Device(s) Being Used, type = None 18:59:50 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:59:50 XMAG Device(s) Being Used, type = None 18:59:50 Ambient Measurement Device(s) Being Used, type = None 18:59:56   Voltage Measurement, V = 0.000000 V 18:59:57 Temperature Measurement, Probe Number = 0, T = 25.873000 C 18:59:57 Temperature Measurement, Probe Number = 1, T = 26.806000 C 18:59:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.87 P2 = 3458_Meas_Junction, Value = 26.81 18:59:58 Integrated Voltage Measurement... 19:00:24 Voltage Offset Correction: v_off_ini = 0.000004129 V, v_off_fin = 0.000005357 V 19:00:24 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.141880616 Vs 19:00:24 Integrated Voltage Measurement... 19:00:56 Voltage Offset Correction: v_off_ini = 0.000004730 V, v_off_fin = 0.000000780 V 19:00:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141844957 Vs 19:00:57   Voltage Measurement, V = 0.000000 V 19:00:57 Temperature Measurement, Probe Number = 0, T = 25.855000 C 19:00:58 Temperature Measurement, Probe Number = 1, T = 26.793000 C 19:00:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.86 P2 = 3458_Meas_Junction, Value = 26.79 19:00:58 Integrated Voltage Measurement... 19:01:29 Voltage Offset Correction: v_off_ini = 0.000003489 V, v_off_fin = 0.000005709 V 19:01:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.141888483 Vs 19:01:29 Integrated Voltage Measurement... 19:02:03 Voltage Offset Correction: v_off_ini = 0.000004774 V, v_off_fin = 0.000001768 V 19:02:03 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.141846401 Vs 19:02:04   Voltage Measurement, V = 0.000000 V 19:02:04 Temperature Measurement, Probe Number = 0, T = 25.865000 C 19:02:05 Temperature Measurement, Probe Number = 1, T = 26.797000 C 19:02:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.86 P2 = 3458_Meas_Junction, Value = 26.80 19:02:05 Integrated Voltage Measurement... 19:02:37 Voltage Offset Correction: v_off_ini = 0.000003055 V, v_off_fin = 0.000004991 V 19:02:37 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.141895461 Vs 19:02:37 Integrated Voltage Measurement... 19:03:08 Voltage Offset Correction: v_off_ini = 0.000004637 V, v_off_fin = 0.000001796 V 19:03:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141844460 Vs 19:03:09   Voltage Measurement, V = 0.000000 V 19:03:09 Temperature Measurement, Probe Number = 0, T = 25.859000 C 19:03:10 Temperature Measurement, Probe Number = 1, T = 26.798000 C 19:03:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.86 P2 = 3458_Meas_Junction, Value = 26.80 19:03:10 Integrated Voltage Measurement... 19:03:41 Voltage Offset Correction: v_off_ini = 0.000002989 V, v_off_fin = 0.000004839 V 19:03:41 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.141895733 Vs 19:03:41 Integrated Voltage Measurement... 19:04:14 Voltage Offset Correction: v_off_ini = 0.000004765 V, v_off_fin = -0.000000136 V 19:04:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141840523 Vs 19:04:15   Voltage Measurement, V = 0.000000 V 19:04:15 Temperature Measurement, Probe Number = 0, T = 25.869000 C 19:04:16 Temperature Measurement, Probe Number = 1, T = 26.801000 C 19:04:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.87 P2 = 3458_Meas_Junction, Value = 26.80 19:04:16 Integrated Voltage Measurement... 19:04:49 Voltage Offset Correction: v_off_ini = 0.000003056 V, v_off_fin = 0.000005106 V 19:04:49 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.141893412 Vs 19:04:49 Integrated Voltage Measurement... 19:05:20 Voltage Offset Correction: v_off_ini = 0.000004456 V, v_off_fin = 0.000001278 V 19:05:20 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.141848848 Vs 19:05:21   Voltage Measurement, V = 0.000000 V 19:05:22 Temperature Measurement, Probe Number = 0, T = 25.859000 C 19:05:22 Temperature Measurement, Probe Number = 1, T = 26.799000 C 19:05:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.86 P2 = 3458_Meas_Junction, Value = 26.80 19:05:22 Integrated Voltage Measurement... 19:05:54 Voltage Offset Correction: v_off_ini = 0.000003331 V, v_off_fin = 0.000004597 V 19:05:54 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.141900744 Vs 19:05:54 Integrated Voltage Measurement... 19:06:25 Voltage Offset Correction: v_off_ini = 0.000004374 V, v_off_fin = 0.000001591 V 19:06:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141838138 Vs 19:06:26   Voltage Measurement, V = 0.000000 V 19:06:26 Temperature Measurement, Probe Number = 0, T = 25.855000 C 19:06:27 Temperature Measurement, Probe Number = 1, T = 26.798000 C 19:06:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.86 P2 = 3458_Meas_Junction, Value = 26.80 19:06:27 Integrated Voltage Measurement... 19:06:58 Voltage Offset Correction: v_off_ini = 0.000003231 V, v_off_fin = 0.000004740 V 19:06:58 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.141903162 Vs 19:06:58 Integrated Voltage Measurement... 19:07:30 Voltage Offset Correction: v_off_ini = 0.000004200 V, v_off_fin = 0.000000761 V 19:07:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141835512 Vs 19:07:31   Voltage Measurement, V = 0.000000 V 19:07:31 Temperature Measurement, Probe Number = 0, T = 25.849000 C 19:07:32 Temperature Measurement, Probe Number = 1, T = 26.789000 C 19:07:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.85 P2 = 3458_Meas_Junction, Value = 26.79 19:07:32 Integrated Voltage Measurement... 19:08:03 Voltage Offset Correction: v_off_ini = 0.000003777 V, v_off_fin = 0.000005272 V 19:08:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.141887583 Vs 19:08:03 Integrated Voltage Measurement... 19:08:34 Voltage Offset Correction: v_off_ini = 0.000004706 V, v_off_fin = 0.000001792 V 19:08:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141831976 Vs 19:08:35   Voltage Measurement, V = 0.000000 V 19:08:35 Temperature Measurement, Probe Number = 0, T = 25.849000 C 19:08:36 Temperature Measurement, Probe Number = 1, T = 26.784000 C 19:08:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.85 P2 = 3458_Meas_Junction, Value = 26.78 19:08:36 Integrated Voltage Measurement... 19:09:07 Voltage Offset Correction: v_off_ini = 0.000003080 V, v_off_fin = 0.000004895 V 19:09:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.141881690 Vs 19:09:07 Integrated Voltage Measurement... 19:09:37 Voltage Offset Correction: v_off_ini = 0.000004449 V, v_off_fin = 0.000000955 V 19:09:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141835640 Vs 19:09:38   Voltage Measurement, V = 0.000000 V 19:09:39 Temperature Measurement, Probe Number = 0, T = 25.834000 C 19:09:40 Temperature Measurement, Probe Number = 1, T = 26.773000 C 19:09:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.83 P2 = 3458_Meas_Junction, Value = 26.77 19:09:40 Integrated Voltage Measurement... 19:10:11 Voltage Offset Correction: v_off_ini = 0.000003112 V, v_off_fin = 0.000005281 V 19:10:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.141884410 Vs 19:10:11 Integrated Voltage Measurement... 19:10:42 Voltage Offset Correction: v_off_ini = 0.000004549 V, v_off_fin = 0.000001287 V 19:10:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141835356 Vs