SLAC Magnetic Measurements Date: 10-05-2020 Time: 16:44:17 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_020_Cell_39_Upstairs Serial Number: PC97084 Run Number: 3 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 3 16:44:20 Ambient Measurement Device(s) Being Used, type = None 16:44:20 Magnet Voltage Measurement Device(s) Being Used, type = None 16:44:20 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:44:20 XMAG Device(s) Being Used, type = None 16:44:20 Ambient Measurement Device(s) Being Used, type = None 16:44:30   Voltage Measurement, V = 0.000000 V 16:44:31 Temperature Measurement, Probe Number = 0, T = 27.796000 C 16:44:31 Temperature Measurement, Probe Number = 1, T = 27.852000 C 16:44:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.80 P2 = 3458_Meas_Junction, Value = 27.85 16:44:31 Integrated Voltage Measurement... 16:45:02 Voltage Offset Correction: v_off_ini = 0.000006345 V, v_off_fin = 0.000007900 V 16:45:02 Integrated Voltage Measurement Delta Gap = 0.0040020 m VT = 0.142950178 Vs 16:45:02 Integrated Voltage Measurement... 16:45:36 Voltage Offset Correction: v_off_ini = 0.000006973 V, v_off_fin = 0.000003605 V 16:45:36 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142884559 Vs 16:45:37   Voltage Measurement, V = 0.000000 V 16:45:37 Temperature Measurement, Probe Number = 0, T = 27.786000 C 16:45:38 Temperature Measurement, Probe Number = 1, T = 27.837000 C 16:45:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.79 P2 = 3458_Meas_Junction, Value = 27.84 16:45:38 Integrated Voltage Measurement... 16:46:13 Voltage Offset Correction: v_off_ini = 0.000005422 V, v_off_fin = 0.000007625 V 16:46:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142927306 Vs 16:46:13 Integrated Voltage Measurement... 16:46:47 Voltage Offset Correction: v_off_ini = 0.000006993 V, v_off_fin = 0.000002881 V 16:46:47 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142904822 Vs 16:46:48   Voltage Measurement, V = 0.000000 V 16:46:49 Temperature Measurement, Probe Number = 0, T = 27.787000 C 16:46:49 Temperature Measurement, Probe Number = 1, T = 27.837000 C 16:46:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.79 P2 = 3458_Meas_Junction, Value = 27.84 16:46:49 Integrated Voltage Measurement... 16:47:23 Voltage Offset Correction: v_off_ini = 0.000005503 V, v_off_fin = 0.000006923 V 16:47:23 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142950996 Vs 16:47:23 Integrated Voltage Measurement... 16:47:55 Voltage Offset Correction: v_off_ini = 0.000007224 V, v_off_fin = 0.000004144 V 16:47:55 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142906104 Vs 16:47:56   Voltage Measurement, V = 0.000000 V 16:47:57 Temperature Measurement, Probe Number = 0, T = 27.780000 C 16:47:57 Temperature Measurement, Probe Number = 1, T = 27.832000 C 16:47:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.78 P2 = 3458_Meas_Junction, Value = 27.83 16:47:57 Integrated Voltage Measurement... 16:48:38 Voltage Offset Correction: v_off_ini = 0.000005739 V, v_off_fin = 0.000007326 V 16:48:38 Integrated Voltage Measurement Delta Gap = 0.0040020 m VT = 0.142955235 Vs 16:48:38 Integrated Voltage Measurement... 16:49:11 Voltage Offset Correction: v_off_ini = 0.000006871 V, v_off_fin = 0.000002631 V 16:49:11 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142916294 Vs 16:49:12   Voltage Measurement, V = 0.000000 V 16:49:13 Temperature Measurement, Probe Number = 0, T = 27.771000 C 16:49:13 Temperature Measurement, Probe Number = 1, T = 27.821000 C 16:49:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.77 P2 = 3458_Meas_Junction, Value = 27.82 16:49:13 Integrated Voltage Measurement... 16:49:48 Voltage Offset Correction: v_off_ini = 0.000005478 V, v_off_fin = 0.000007759 V 16:49:48 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142955842 Vs 16:49:48 Integrated Voltage Measurement... 16:50:22 Voltage Offset Correction: v_off_ini = 0.000006797 V, v_off_fin = 0.000003164 V 16:50:22 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142900575 Vs 16:50:23   Voltage Measurement, V = 0.000000 V 16:50:24 Temperature Measurement, Probe Number = 0, T = 27.772000 C 16:50:24 Temperature Measurement, Probe Number = 1, T = 27.820000 C 16:50:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.77 P2 = 3458_Meas_Junction, Value = 27.82 16:50:24 Integrated Voltage Measurement... 16:50:58 Voltage Offset Correction: v_off_ini = 0.000005160 V, v_off_fin = 0.000007906 V 16:50:58 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142950145 Vs 16:50:58 Integrated Voltage Measurement... 16:51:30 Voltage Offset Correction: v_off_ini = 0.000006955 V, v_off_fin = 0.000002349 V 16:51:30 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142899755 Vs 16:51:31   Voltage Measurement, V = 0.000000 V 16:51:32 Temperature Measurement, Probe Number = 0, T = 27.761000 C 16:51:32 Temperature Measurement, Probe Number = 1, T = 27.809000 C 16:51:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.76 P2 = 3458_Meas_Junction, Value = 27.81 16:51:32 Integrated Voltage Measurement... 16:52:04 Voltage Offset Correction: v_off_ini = 0.000004896 V, v_off_fin = 0.000007079 V 16:52:04 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142955335 Vs 16:52:04 Integrated Voltage Measurement... 16:52:36 Voltage Offset Correction: v_off_ini = 0.000007093 V, v_off_fin = 0.000003341 V 16:52:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142896132 Vs 16:52:37   Voltage Measurement, V = 0.000000 V 16:52:37 Temperature Measurement, Probe Number = 0, T = 27.765000 C 16:52:38 Temperature Measurement, Probe Number = 1, T = 27.814000 C 16:52:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.77 P2 = 3458_Meas_Junction, Value = 27.81 16:52:38 Integrated Voltage Measurement... 16:53:11 Voltage Offset Correction: v_off_ini = 0.000005246 V, v_off_fin = 0.000007790 V 16:53:12 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142941944 Vs 16:53:12 Integrated Voltage Measurement... 16:53:45 Voltage Offset Correction: v_off_ini = 0.000007081 V, v_off_fin = 0.000003101 V 16:53:45 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142896946 Vs 16:53:46   Voltage Measurement, V = 0.000000 V 16:53:46 Temperature Measurement, Probe Number = 0, T = 27.751000 C 16:53:47 Temperature Measurement, Probe Number = 1, T = 27.797000 C 16:53:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 27.80 16:53:47 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = 0.000005152 V, v_off_fin = 0.000008119 V 16:54:17 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142950104 Vs 16:54:17 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = 0.000007075 V, v_off_fin = 0.000003062 V 16:54:51 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142898195 Vs 16:54:52   Voltage Measurement, V = 0.000000 V 16:54:52 Temperature Measurement, Probe Number = 0, T = 27.753000 C 16:54:53 Temperature Measurement, Probe Number = 1, T = 27.794000 C 16:54:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 27.79 16:54:53 Integrated Voltage Measurement... 16:55:28 Voltage Offset Correction: v_off_ini = 0.000005179 V, v_off_fin = 0.000007363 V 16:55:28 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142946269 Vs 16:55:28 Integrated Voltage Measurement... 16:56:00 Voltage Offset Correction: v_off_ini = 0.000006651 V, v_off_fin = 0.000002803 V 16:56:00 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142896493 Vs