SLAC Magnetic Measurements Date: 07-15-2020 Time: 08:44:27 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_020_Cell_39 Serial Number: HP_PC33408 Run Number: 6 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 6 08:44:29 Ambient Measurement Device(s) Being Used, type = None 08:44:29 Magnet Voltage Measurement Device(s) Being Used, type = None 08:44:30 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 08:44:30 XMAG Device(s) Being Used, type = None 08:44:30 Ambient Measurement Device(s) Being Used, type = None 08:44:42   Voltage Measurement, V = 0.000000 V 08:44:43 Temperature Measurement, Probe Number = 0, T = 22.200000 C 08:44:44 Temperature Measurement, Probe Number = 1, T = 22.833000 C 08:44:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.20 P2 = 3458_Meas_Junction, Value = 22.83 08:44:44 Integrated Voltage Measurement... 08:45:15 Voltage Offset Correction: v_off_ini = -0.000000254 V, v_off_fin = 0.000001210 V 08:45:15 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142760758 Vs 08:45:15 Integrated Voltage Measurement... 08:45:47 Voltage Offset Correction: v_off_ini = 0.000000242 V, v_off_fin = -0.000001734 V 08:45:47 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142766272 Vs 08:45:48   Voltage Measurement, V = 0.000000 V 08:45:48 Temperature Measurement, Probe Number = 0, T = 22.166000 C 08:45:49 Temperature Measurement, Probe Number = 1, T = 22.842000 C 08:45:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.17 P2 = 3458_Meas_Junction, Value = 22.84 08:45:49 Integrated Voltage Measurement... 08:46:22 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = 0.000000134 V 08:46:22 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142799952 Vs 08:46:22 Integrated Voltage Measurement... 08:46:52 Voltage Offset Correction: v_off_ini = -0.000000053 V, v_off_fin = -0.000002819 V 08:46:52 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142760893 Vs 08:46:53   Voltage Measurement, V = 0.000000 V 08:46:54 Temperature Measurement, Probe Number = 0, T = 22.135000 C 08:46:54 Temperature Measurement, Probe Number = 1, T = 22.844000 C 08:46:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.14 P2 = 3458_Meas_Junction, Value = 22.84 08:46:54 Integrated Voltage Measurement... 08:47:24 Voltage Offset Correction: v_off_ini = -0.000001526 V, v_off_fin = 0.000000564 V 08:47:24 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142812101 Vs 08:47:24 Integrated Voltage Measurement... 08:47:58 Voltage Offset Correction: v_off_ini = -0.000000179 V, v_off_fin = -0.000003259 V 08:47:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142771922 Vs 08:47:59   Voltage Measurement, V = 0.000000 V 08:47:59 Temperature Measurement, Probe Number = 0, T = 22.137000 C 08:48:00 Temperature Measurement, Probe Number = 1, T = 22.852000 C 08:48:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.14 P2 = 3458_Meas_Junction, Value = 22.85 08:48:00 Integrated Voltage Measurement... 08:48:30 Voltage Offset Correction: v_off_ini = -0.000001585 V, v_off_fin = -0.000000168 V 08:48:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142810182 Vs 08:48:30 Integrated Voltage Measurement... 08:49:07 Voltage Offset Correction: v_off_ini = -0.000000053 V, v_off_fin = -0.000001941 V 08:49:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142771379 Vs 08:49:08   Voltage Measurement, V = 0.000000 V 08:49:08 Temperature Measurement, Probe Number = 0, T = 22.099000 C 08:49:09 Temperature Measurement, Probe Number = 1, T = 22.871000 C 08:49:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.10 P2 = 3458_Meas_Junction, Value = 22.87 08:49:09 Integrated Voltage Measurement... 08:49:42 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = 0.000000446 V 08:49:42 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142798616 Vs 08:49:42 Integrated Voltage Measurement... 08:50:15 Voltage Offset Correction: v_off_ini = 0.000000067 V, v_off_fin = -0.000004218 V 08:50:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142767380 Vs 08:50:16   Voltage Measurement, V = 0.000000 V 08:50:17 Temperature Measurement, Probe Number = 0, T = 22.074000 C 08:50:17 Temperature Measurement, Probe Number = 1, T = 22.869000 C 08:50:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.07 P2 = 3458_Meas_Junction, Value = 22.87 08:50:17 Integrated Voltage Measurement... 08:50:48 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = 0.000000057 V 08:50:48 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142796439 Vs 08:50:48 Integrated Voltage Measurement... 08:51:24 Voltage Offset Correction: v_off_ini = -0.000000093 V, v_off_fin = -0.000003462 V 08:51:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142762738 Vs 08:51:25   Voltage Measurement, V = 0.000000 V 08:51:25 Temperature Measurement, Probe Number = 0, T = 22.064000 C 08:51:26 Temperature Measurement, Probe Number = 1, T = 22.882000 C 08:51:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.06 P2 = 3458_Meas_Junction, Value = 22.88 08:51:26 Integrated Voltage Measurement... 08:51:57 Voltage Offset Correction: v_off_ini = -0.000001342 V, v_off_fin = -0.000000056 V 08:51:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142796203 Vs 08:51:58 Integrated Voltage Measurement... 08:52:29 Voltage Offset Correction: v_off_ini = -0.000000051 V, v_off_fin = -0.000003447 V 08:52:29 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142772344 Vs 08:52:30   Voltage Measurement, V = 0.000000 V 08:52:31 Temperature Measurement, Probe Number = 0, T = 22.054000 C 08:52:31 Temperature Measurement, Probe Number = 1, T = 22.877000 C 08:52:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.05 P2 = 3458_Meas_Junction, Value = 22.88 08:52:31 Integrated Voltage Measurement... 08:53:07 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = 0.000001359 V 08:53:07 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142795227 Vs 08:53:07 Integrated Voltage Measurement... 08:53:41 Voltage Offset Correction: v_off_ini = -0.000000042 V, v_off_fin = -0.000002358 V 08:53:41 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142767383 Vs 08:53:42   Voltage Measurement, V = 0.000000 V 08:53:42 Temperature Measurement, Probe Number = 0, T = 22.030000 C 08:53:43 Temperature Measurement, Probe Number = 1, T = 22.871000 C 08:53:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.03 P2 = 3458_Meas_Junction, Value = 22.87 08:53:43 Integrated Voltage Measurement... 08:54:16 Voltage Offset Correction: v_off_ini = -0.000001411 V, v_off_fin = 0.000000398 V 08:54:16 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142804190 Vs 08:54:16 Integrated Voltage Measurement... 08:54:48 Voltage Offset Correction: v_off_ini = 0.000000091 V, v_off_fin = -0.000002875 V 08:54:48 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142776425 Vs 08:54:49   Voltage Measurement, V = 0.000000 V 08:54:50 Temperature Measurement, Probe Number = 0, T = 22.018000 C 08:54:50 Temperature Measurement, Probe Number = 1, T = 22.854000 C 08:54:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.02 P2 = 3458_Meas_Junction, Value = 22.85 08:54:50 Integrated Voltage Measurement... 08:55:22 Voltage Offset Correction: v_off_ini = -0.000001481 V, v_off_fin = 0.000000217 V 08:55:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142813137 Vs 08:55:22 Integrated Voltage Measurement... 08:55:56 Voltage Offset Correction: v_off_ini = -0.000000039 V, v_off_fin = -0.000003541 V 08:55:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142774370 Vs