SLAC Magnetic Measurements Date: 01-07-2021 Time: 16:03:19 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_020_Cell_39 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 16:03:37 Ambient Measurement Device(s) Being Used, type = None 16:03:37 Magnet Voltage Measurement Device(s) Being Used, type = None 16:03:37 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:03:37 XMAG Device(s) Being Used, type = None 16:03:37 Ambient Measurement Device(s) Being Used, type = None 16:03:47   Voltage Measurement, V = 0.000000 V 16:03:48 Temperature Measurement, Probe Number = 0, T = 21.029000 C 16:03:48 Temperature Measurement, Probe Number = 1, T = 21.927000 C 16:03:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 21.93 16:03:48 Integrated Voltage Measurement... 16:04:27 Voltage Offset Correction: v_off_ini = 0.000000149 V, v_off_fin = 0.000000717 V 16:04:27 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142792371 Vs 16:04:27 Integrated Voltage Measurement... 16:04:58 Voltage Offset Correction: v_off_ini = 0.000000641 V, v_off_fin = -0.000002750 V 16:04:59 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142843595 Vs 16:05:00   Voltage Measurement, V = 0.000000 V 16:05:00 Temperature Measurement, Probe Number = 0, T = 21.034000 C 16:05:01 Temperature Measurement, Probe Number = 1, T = 21.946000 C 16:05:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 21.95 16:05:01 Integrated Voltage Measurement... 16:05:38 Voltage Offset Correction: v_off_ini = -0.000000661 V, v_off_fin = 0.000001217 V 16:05:38 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142900439 Vs 16:05:38 Integrated Voltage Measurement... 16:06:12 Voltage Offset Correction: v_off_ini = 0.000000712 V, v_off_fin = -0.000002639 V 16:06:12 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142854382 Vs 16:06:13   Voltage Measurement, V = 0.000000 V 16:06:13 Temperature Measurement, Probe Number = 0, T = 21.049000 C 16:06:14 Temperature Measurement, Probe Number = 1, T = 21.951000 C 16:06:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.05 P2 = 3458_Meas_Junction, Value = 21.95 16:06:14 Integrated Voltage Measurement... 16:06:46 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = 0.000001163 V 16:06:46 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142899930 Vs 16:06:46 Integrated Voltage Measurement... 16:07:18 Voltage Offset Correction: v_off_ini = 0.000001030 V, v_off_fin = -0.000004170 V 16:07:18 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142850377 Vs 16:07:19   Voltage Measurement, V = 0.000000 V 16:07:19 Temperature Measurement, Probe Number = 0, T = 21.047000 C 16:07:20 Temperature Measurement, Probe Number = 1, T = 21.939000 C 16:07:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.05 P2 = 3458_Meas_Junction, Value = 21.94 16:07:20 Integrated Voltage Measurement... 16:07:53 Voltage Offset Correction: v_off_ini = -0.000001255 V, v_off_fin = 0.000001255 V 16:07:53 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142897754 Vs 16:07:53 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = 0.000000739 V, v_off_fin = -0.000003572 V 16:08:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142832382 Vs 16:08:26   Voltage Measurement, V = 0.000000 V 16:08:27 Temperature Measurement, Probe Number = 0, T = 21.036000 C 16:08:28 Temperature Measurement, Probe Number = 1, T = 21.929000 C 16:08:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.04 P2 = 3458_Meas_Junction, Value = 21.93 16:08:28 Integrated Voltage Measurement... 16:08:55 Voltage Offset Correction: v_off_ini = -0.000001499 V, v_off_fin = 0.000001605 V 16:08:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142890122 Vs 16:08:55 Integrated Voltage Measurement... 16:09:26 Voltage Offset Correction: v_off_ini = 0.000001007 V, v_off_fin = -0.000003124 V 16:09:26 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142841810 Vs 16:09:27   Voltage Measurement, V = 0.000000 V 16:09:28 Temperature Measurement, Probe Number = 0, T = 21.027000 C 16:09:29 Temperature Measurement, Probe Number = 1, T = 21.916000 C 16:09:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 21.92 16:09:29 Integrated Voltage Measurement... 16:10:00 Voltage Offset Correction: v_off_ini = -0.000001091 V, v_off_fin = 0.000002028 V 16:10:00 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142881573 Vs 16:10:00 Integrated Voltage Measurement... 16:10:30 Voltage Offset Correction: v_off_ini = 0.000001189 V, v_off_fin = -0.000003971 V 16:10:30 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142846887 Vs 16:10:31   Voltage Measurement, V = 0.000000 V 16:10:31 Temperature Measurement, Probe Number = 0, T = 21.024000 C 16:10:32 Temperature Measurement, Probe Number = 1, T = 21.921000 C 16:10:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 21.92 16:10:32 Integrated Voltage Measurement... 16:11:03 Voltage Offset Correction: v_off_ini = -0.000001197 V, v_off_fin = 0.000002169 V 16:11:03 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142903877 Vs 16:11:03 Integrated Voltage Measurement... 16:11:35 Voltage Offset Correction: v_off_ini = 0.000000822 V, v_off_fin = -0.000003455 V 16:11:35 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.142856871 Vs 16:11:36   Voltage Measurement, V = 0.000000 V 16:11:37 Temperature Measurement, Probe Number = 0, T = 21.017000 C 16:11:37 Temperature Measurement, Probe Number = 1, T = 21.921000 C 16:11:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 21.92 16:11:37 Integrated Voltage Measurement... 16:12:08 Voltage Offset Correction: v_off_ini = -0.000001184 V, v_off_fin = 0.000001446 V 16:12:08 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142905311 Vs 16:12:08 Integrated Voltage Measurement... 16:12:39 Voltage Offset Correction: v_off_ini = 0.000001009 V, v_off_fin = -0.000003424 V 16:12:39 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142846220 Vs 16:12:40   Voltage Measurement, V = 0.000000 V 16:12:41 Temperature Measurement, Probe Number = 0, T = 21.010000 C 16:12:42 Temperature Measurement, Probe Number = 1, T = 21.919000 C 16:12:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.01 P2 = 3458_Meas_Junction, Value = 21.92 16:12:42 Integrated Voltage Measurement... 16:13:12 Voltage Offset Correction: v_off_ini = -0.000001222 V, v_off_fin = 0.000001028 V 16:13:12 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142892609 Vs 16:13:12 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = 0.000000859 V, v_off_fin = -0.000003573 V 16:13:43 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142843075 Vs 16:13:44   Voltage Measurement, V = 0.000000 V 16:13:44 Temperature Measurement, Probe Number = 0, T = 21.008000 C 16:13:45 Temperature Measurement, Probe Number = 1, T = 21.911000 C 16:13:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.01 P2 = 3458_Meas_Junction, Value = 21.91 16:13:45 Integrated Voltage Measurement... 16:14:16 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = 0.000001114 V 16:14:16 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142887777 Vs 16:14:16 Integrated Voltage Measurement... 16:14:46 Voltage Offset Correction: v_off_ini = 0.000001012 V, v_off_fin = -0.000002054 V 16:14:46 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142843206 Vs