SLAC Magnetic Measurements Date: 10-06-2020 Time: 16:34:07 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_020_Cell_39 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 16:34:09 Ambient Measurement Device(s) Being Used, type = None 16:34:09 Magnet Voltage Measurement Device(s) Being Used, type = None 16:34:10 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:34:10 XMAG Device(s) Being Used, type = None 16:34:10 Ambient Measurement Device(s) Being Used, type = None 16:34:15   Voltage Measurement, V = 0.000000 V 16:34:16 Temperature Measurement, Probe Number = 0, T = 21.353000 C 16:34:17 Temperature Measurement, Probe Number = 1, T = 21.478000 C 16:34:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.35 P2 = 3458_Meas_Junction, Value = 21.48 16:34:17 Integrated Voltage Measurement... 16:34:43 Voltage Offset Correction: v_off_ini = -0.000000542 V, v_off_fin = 0.000001513 V 16:34:43 Integrated Voltage Measurement Delta Gap = 0.0040021 m VT = 0.142945341 Vs 16:34:43 Integrated Voltage Measurement... 16:35:16 Voltage Offset Correction: v_off_ini = 0.000000157 V, v_off_fin = -0.000003429 V 16:35:16 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142884474 Vs 16:35:17   Voltage Measurement, V = 0.000000 V 16:35:18 Temperature Measurement, Probe Number = 0, T = 21.353000 C 16:35:19 Temperature Measurement, Probe Number = 1, T = 21.481000 C 16:35:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.35 P2 = 3458_Meas_Junction, Value = 21.48 16:35:19 Integrated Voltage Measurement... 16:35:57 Voltage Offset Correction: v_off_ini = -0.000001523 V, v_off_fin = 0.000000549 V 16:35:57 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142933879 Vs 16:35:57 Integrated Voltage Measurement... 16:36:29 Voltage Offset Correction: v_off_ini = 0.000000157 V, v_off_fin = -0.000004948 V 16:36:29 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142898034 Vs 16:36:30   Voltage Measurement, V = 0.000000 V 16:36:31 Temperature Measurement, Probe Number = 0, T = 21.376000 C 16:36:31 Temperature Measurement, Probe Number = 1, T = 21.482000 C 16:36:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.38 P2 = 3458_Meas_Junction, Value = 21.48 16:36:31 Integrated Voltage Measurement... 16:37:05 Voltage Offset Correction: v_off_ini = -0.000001794 V, v_off_fin = 0.000000301 V 16:37:05 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142944514 Vs 16:37:05 Integrated Voltage Measurement... 16:37:37 Voltage Offset Correction: v_off_ini = 0.000000329 V, v_off_fin = -0.000004077 V 16:37:37 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142892137 Vs 16:37:38   Voltage Measurement, V = 0.000000 V 16:37:39 Temperature Measurement, Probe Number = 0, T = 21.370000 C 16:37:39 Temperature Measurement, Probe Number = 1, T = 21.490000 C 16:37:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.37 P2 = 3458_Meas_Junction, Value = 21.49 16:37:39 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = -0.000001604 V, v_off_fin = 0.000000818 V 16:38:12 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142948794 Vs 16:38:12 Integrated Voltage Measurement... 16:38:44 Voltage Offset Correction: v_off_ini = 0.000000066 V, v_off_fin = -0.000004126 V 16:38:44 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142881127 Vs 16:38:45   Voltage Measurement, V = 0.000000 V 16:38:46 Temperature Measurement, Probe Number = 0, T = 21.390000 C 16:38:46 Temperature Measurement, Probe Number = 1, T = 21.484000 C 16:38:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 21.48 16:38:46 Integrated Voltage Measurement... 16:39:18 Voltage Offset Correction: v_off_ini = -0.000001764 V, v_off_fin = 0.000000900 V 16:39:18 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142931533 Vs 16:39:18 Integrated Voltage Measurement... 16:39:51 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = -0.000004695 V 16:39:51 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142891537 Vs 16:39:52   Voltage Measurement, V = 0.000000 V 16:39:52 Temperature Measurement, Probe Number = 0, T = 21.386000 C 16:39:53 Temperature Measurement, Probe Number = 1, T = 21.481000 C 16:39:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 21.48 16:39:53 Integrated Voltage Measurement... 16:40:23 Voltage Offset Correction: v_off_ini = -0.000002014 V, v_off_fin = 0.000000329 V 16:40:23 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142941154 Vs 16:40:23 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = -0.000000023 V, v_off_fin = -0.000004019 V 16:41:00 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.142900142 Vs 16:41:01   Voltage Measurement, V = 0.000000 V 16:41:02 Temperature Measurement, Probe Number = 0, T = 21.386000 C 16:41:02 Temperature Measurement, Probe Number = 1, T = 21.495000 C 16:41:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 21.50 16:41:02 Integrated Voltage Measurement... 16:41:35 Voltage Offset Correction: v_off_ini = -0.000001854 V, v_off_fin = 0.000000558 V 16:41:35 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142933739 Vs 16:41:35 Integrated Voltage Measurement... 16:42:16 Voltage Offset Correction: v_off_ini = 0.000000051 V, v_off_fin = -0.000003990 V 16:42:16 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142889555 Vs 16:42:17   Voltage Measurement, V = 0.000000 V 16:42:18 Temperature Measurement, Probe Number = 0, T = 21.397000 C 16:42:18 Temperature Measurement, Probe Number = 1, T = 21.498000 C 16:42:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.40 P2 = 3458_Meas_Junction, Value = 21.50 16:42:18 Integrated Voltage Measurement... 16:42:51 Voltage Offset Correction: v_off_ini = -0.000001635 V, v_off_fin = 0.000000545 V 16:42:51 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142933272 Vs 16:42:51 Integrated Voltage Measurement... 16:43:21 Voltage Offset Correction: v_off_ini = 0.000000341 V, v_off_fin = -0.000004435 V 16:43:21 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142895134 Vs 16:43:22   Voltage Measurement, V = 0.000000 V 16:43:23 Temperature Measurement, Probe Number = 0, T = 21.387000 C 16:43:23 Temperature Measurement, Probe Number = 1, T = 21.468000 C 16:43:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 21.47 16:43:23 Integrated Voltage Measurement... 16:44:01 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = 0.000001761 V 16:44:01 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142943556 Vs 16:44:01 Integrated Voltage Measurement... 16:44:33 Voltage Offset Correction: v_off_ini = 0.000000208 V, v_off_fin = -0.000003991 V 16:44:33 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142883238 Vs 16:44:34   Voltage Measurement, V = 0.000000 V 16:44:35 Temperature Measurement, Probe Number = 0, T = 21.372000 C 16:44:36 Temperature Measurement, Probe Number = 1, T = 21.455000 C 16:44:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.37 P2 = 3458_Meas_Junction, Value = 21.45 16:44:36 Integrated Voltage Measurement... 16:45:06 Voltage Offset Correction: v_off_ini = -0.000001852 V, v_off_fin = 0.000001497 V 16:45:06 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142924197 Vs 16:45:06 Integrated Voltage Measurement... 16:45:40 Voltage Offset Correction: v_off_ini = 0.000000017 V, v_off_fin = -0.000003284 V 16:45:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142855388 Vs