SLAC Magnetic Measurements Date: 09-09-2020 Time: 15:07:59 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_019_Cell_45_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 15:08:01 Ambient Measurement Device(s) Being Used, type = None 15:08:01 Magnet Voltage Measurement Device(s) Being Used, type = None 15:08:02 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:08:02 XMAG Device(s) Being Used, type = None 15:08:02 Ambient Measurement Device(s) Being Used, type = None 15:08:08   Voltage Measurement, V = 0.000000 V 15:08:08 Temperature Measurement, Probe Number = 0, T = 27.188000 C 15:08:09 Temperature Measurement, Probe Number = 1, T = 28.606000 C 15:08:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.19 P2 = 3458_Meas_Junction, Value = 28.61 15:08:09 Integrated Voltage Measurement... 15:08:41 Voltage Offset Correction: v_off_ini = 0.000005500 V, v_off_fin = 0.000006981 V 15:08:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142885549 Vs 15:08:41 Integrated Voltage Measurement... 15:09:16 Voltage Offset Correction: v_off_ini = 0.000005927 V, v_off_fin = 0.000002821 V 15:09:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142867634 Vs 15:09:17   Voltage Measurement, V = 0.000000 V 15:09:18 Temperature Measurement, Probe Number = 0, T = 27.175000 C 15:09:18 Temperature Measurement, Probe Number = 1, T = 28.000000 C 15:09:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 28.00 15:09:18 Integrated Voltage Measurement... 15:09:49 Voltage Offset Correction: v_off_ini = 0.000004692 V, v_off_fin = 0.000006336 V 15:09:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142885638 Vs 15:09:49 Integrated Voltage Measurement... 15:10:22 Voltage Offset Correction: v_off_ini = 0.000006093 V, v_off_fin = 0.000003756 V 15:10:22 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142863691 Vs 15:10:23   Voltage Measurement, V = 0.000000 V 15:10:24 Temperature Measurement, Probe Number = 0, T = 27.174000 C 15:10:24 Temperature Measurement, Probe Number = 1, T = 27.700000 C 15:10:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.17 P2 = 3458_Meas_Junction, Value = 27.70 15:10:24 Integrated Voltage Measurement... 15:10:54 Voltage Offset Correction: v_off_ini = 0.000004494 V, v_off_fin = 0.000005978 V 15:10:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142896799 Vs 15:10:55 Integrated Voltage Measurement... 15:11:28 Voltage Offset Correction: v_off_ini = 0.000006113 V, v_off_fin = 0.000003024 V 15:11:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142854754 Vs 15:11:30   Voltage Measurement, V = 0.000000 V 15:11:30 Temperature Measurement, Probe Number = 0, T = 27.182000 C 15:11:31 Temperature Measurement, Probe Number = 1, T = 27.532000 C 15:11:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 27.53 15:11:31 Integrated Voltage Measurement... 15:12:03 Voltage Offset Correction: v_off_ini = 0.000004851 V, v_off_fin = 0.000005991 V 15:12:03 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142877465 Vs 15:12:03 Integrated Voltage Measurement... 15:12:38 Voltage Offset Correction: v_off_ini = 0.000005894 V, v_off_fin = 0.000004000 V 15:12:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142852020 Vs 15:12:39   Voltage Measurement, V = 0.000000 V 15:12:40 Temperature Measurement, Probe Number = 0, T = 27.179000 C 15:12:40 Temperature Measurement, Probe Number = 1, T = 27.434000 C 15:12:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 27.43 15:12:40 Integrated Voltage Measurement... 15:13:10 Voltage Offset Correction: v_off_ini = 0.000004772 V, v_off_fin = 0.000005955 V 15:13:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142893767 Vs 15:13:11 Integrated Voltage Measurement... 15:13:42 Voltage Offset Correction: v_off_ini = 0.000006078 V, v_off_fin = 0.000003270 V 15:13:42 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142852487 Vs 15:13:43   Voltage Measurement, V = 0.000000 V 15:13:43 Temperature Measurement, Probe Number = 0, T = 27.173000 C 15:13:44 Temperature Measurement, Probe Number = 1, T = 27.373000 C 15:13:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.17 P2 = 3458_Meas_Junction, Value = 27.37 15:13:44 Integrated Voltage Measurement... 15:14:16 Voltage Offset Correction: v_off_ini = 0.000004866 V, v_off_fin = 0.000006948 V 15:14:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142898807 Vs 15:14:16 Integrated Voltage Measurement... 15:14:55 Voltage Offset Correction: v_off_ini = 0.000006080 V, v_off_fin = 0.000004095 V 15:14:55 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142848407 Vs 15:14:56   Voltage Measurement, V = 0.000000 V 15:14:56 Temperature Measurement, Probe Number = 0, T = 27.175000 C 15:14:57 Temperature Measurement, Probe Number = 1, T = 27.337000 C 15:14:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 27.34 15:14:57 Integrated Voltage Measurement... 15:15:29 Voltage Offset Correction: v_off_ini = 0.000004874 V, v_off_fin = 0.000005479 V 15:15:29 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142894365 Vs 15:15:29 Integrated Voltage Measurement... 15:16:04 Voltage Offset Correction: v_off_ini = 0.000006018 V, v_off_fin = 0.000003037 V 15:16:04 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142851786 Vs 15:16:05   Voltage Measurement, V = 0.000000 V 15:16:06 Temperature Measurement, Probe Number = 0, T = 27.170000 C 15:16:06 Temperature Measurement, Probe Number = 1, T = 27.311000 C 15:16:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.17 P2 = 3458_Meas_Junction, Value = 27.31 15:16:06 Integrated Voltage Measurement... 15:16:46 Voltage Offset Correction: v_off_ini = 0.000004563 V, v_off_fin = 0.000005039 V 15:16:46 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142879211 Vs 15:16:46 Integrated Voltage Measurement... 15:17:20 Voltage Offset Correction: v_off_ini = 0.000005674 V, v_off_fin = 0.000004211 V 15:17:20 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142858488 Vs 15:17:21   Voltage Measurement, V = 0.000000 V 15:17:22 Temperature Measurement, Probe Number = 0, T = 27.167000 C 15:17:22 Temperature Measurement, Probe Number = 1, T = 27.291000 C 15:17:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.17 P2 = 3458_Meas_Junction, Value = 27.29 15:17:22 Integrated Voltage Measurement... 15:17:52 Voltage Offset Correction: v_off_ini = 0.000004275 V, v_off_fin = 0.000005862 V 15:17:52 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142890451 Vs 15:17:52 Integrated Voltage Measurement... 15:18:23 Voltage Offset Correction: v_off_ini = 0.000005875 V, v_off_fin = 0.000003497 V 15:18:23 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142846759 Vs 15:18:24   Voltage Measurement, V = 0.000000 V 15:18:25 Temperature Measurement, Probe Number = 0, T = 27.166000 C 15:18:25 Temperature Measurement, Probe Number = 1, T = 27.276000 C 15:18:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.17 P2 = 3458_Meas_Junction, Value = 27.28 15:18:25 Integrated Voltage Measurement... 15:18:56 Voltage Offset Correction: v_off_ini = 0.000004604 V, v_off_fin = 0.000006468 V 15:18:56 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142878777 Vs 15:18:56 Integrated Voltage Measurement... 15:19:27 Voltage Offset Correction: v_off_ini = 0.000005848 V, v_off_fin = 0.000003702 V 15:19:27 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142849883 Vs