SLAC Magnetic Measurements Date: 08-26-2020 Time: 18:09:35 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_019_Cell_45 Serial Number: HP_PC33408 Run Number: 7 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 7 18:09:38 Ambient Measurement Device(s) Being Used, type = None 18:09:38 Magnet Voltage Measurement Device(s) Being Used, type = None 18:09:38 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:09:38 XMAG Device(s) Being Used, type = None 18:09:38 Ambient Measurement Device(s) Being Used, type = None 18:09:47   Voltage Measurement, V = 0.000000 V 18:09:48 Temperature Measurement, Probe Number = 0, T = 22.249000 C 18:09:48 Temperature Measurement, Probe Number = 1, T = 22.933000 C 18:09:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.25 P2 = 3458_Meas_Junction, Value = 22.93 18:09:49 Integrated Voltage Measurement... 18:10:25 Voltage Offset Correction: v_off_ini = 0.000000018 V, v_off_fin = 0.000000651 V 18:10:25 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142862795 Vs 18:10:25 Integrated Voltage Measurement... 18:10:59 Voltage Offset Correction: v_off_ini = 0.000000163 V, v_off_fin = -0.000002302 V 18:10:59 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142850511 Vs 18:11:00   Voltage Measurement, V = 0.000000 V 18:11:01 Temperature Measurement, Probe Number = 0, T = 22.236000 C 18:11:02 Temperature Measurement, Probe Number = 1, T = 22.932000 C 18:11:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.24 P2 = 3458_Meas_Junction, Value = 22.93 18:11:02 Integrated Voltage Measurement... 18:11:45 Voltage Offset Correction: v_off_ini = -0.000000596 V, v_off_fin = 0.000000529 V 18:11:45 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142891317 Vs 18:11:45 Integrated Voltage Measurement... 18:12:19 Voltage Offset Correction: v_off_ini = 0.000000365 V, v_off_fin = -0.000002842 V 18:12:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142861130 Vs 18:12:20   Voltage Measurement, V = 0.000000 V 18:12:21 Temperature Measurement, Probe Number = 0, T = 22.296000 C 18:12:21 Temperature Measurement, Probe Number = 1, T = 22.920000 C 18:12:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.30 P2 = 3458_Meas_Junction, Value = 22.92 18:12:21 Integrated Voltage Measurement... 18:12:55 Voltage Offset Correction: v_off_ini = -0.000000999 V, v_off_fin = 0.000001418 V 18:12:55 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142893751 Vs 18:12:55 Integrated Voltage Measurement... 18:13:30 Voltage Offset Correction: v_off_ini = 0.000000480 V, v_off_fin = -0.000002956 V 18:13:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142857185 Vs 18:13:31   Voltage Measurement, V = 0.000000 V 18:13:32 Temperature Measurement, Probe Number = 0, T = 22.331000 C 18:13:32 Temperature Measurement, Probe Number = 1, T = 22.938000 C 18:13:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.33 P2 = 3458_Meas_Junction, Value = 22.94 18:13:32 Integrated Voltage Measurement... 18:14:05 Voltage Offset Correction: v_off_ini = -0.000000903 V, v_off_fin = 0.000000981 V 18:14:05 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142878992 Vs 18:14:05 Integrated Voltage Measurement... 18:14:38 Voltage Offset Correction: v_off_ini = 0.000000194 V, v_off_fin = -0.000002949 V 18:14:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142871978 Vs 18:14:39   Voltage Measurement, V = 0.000000 V 18:14:39 Temperature Measurement, Probe Number = 0, T = 22.328000 C 18:14:40 Temperature Measurement, Probe Number = 1, T = 22.940000 C 18:14:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.33 P2 = 3458_Meas_Junction, Value = 22.94 18:14:40 Integrated Voltage Measurement... 18:15:11 Voltage Offset Correction: v_off_ini = -0.000000867 V, v_off_fin = 0.000000745 V 18:15:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142877732 Vs 18:15:11 Integrated Voltage Measurement... 18:15:42 Voltage Offset Correction: v_off_ini = 0.000000550 V, v_off_fin = -0.000001849 V 18:15:42 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142862840 Vs 18:15:43   Voltage Measurement, V = 0.000000 V 18:15:43 Temperature Measurement, Probe Number = 0, T = 22.346000 C 18:15:44 Temperature Measurement, Probe Number = 1, T = 22.955000 C 18:15:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.35 P2 = 3458_Meas_Junction, Value = 22.95 18:15:44 Integrated Voltage Measurement... 18:16:10 Voltage Offset Correction: v_off_ini = -0.000001228 V, v_off_fin = -0.000000082 V 18:16:10 Integrated Voltage Measurement Delta Gap = -0.0000002 m VT = 0.000003041 Vs 18:16:10 Integrated Voltage Measurement... 18:17:29 Voltage Offset Correction: v_off_ini = 0.000000574 V, v_off_fin = -0.000001858 V 18:17:29 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142841284 Vs 18:17:30   Voltage Measurement, V = 0.000000 V 18:17:31 Temperature Measurement, Probe Number = 0, T = 22.314000 C 18:17:31 Temperature Measurement, Probe Number = 1, T = 22.953000 C 18:17:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.31 P2 = 3458_Meas_Junction, Value = 22.95 18:17:31 Integrated Voltage Measurement... 18:18:10 Voltage Offset Correction: v_off_ini = -0.000000786 V, v_off_fin = 0.000000687 V 18:18:10 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142881131 Vs 18:18:10 Integrated Voltage Measurement... 18:18:41 Voltage Offset Correction: v_off_ini = 0.000000432 V, v_off_fin = -0.000001839 V 18:18:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142870310 Vs 18:18:42   Voltage Measurement, V = 0.000000 V 18:18:43 Temperature Measurement, Probe Number = 0, T = 22.324000 C 18:18:44 Temperature Measurement, Probe Number = 1, T = 22.962000 C 18:18:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.32 P2 = 3458_Meas_Junction, Value = 22.96 18:18:44 Integrated Voltage Measurement... 18:19:15 Voltage Offset Correction: v_off_ini = -0.000000801 V, v_off_fin = 0.000000827 V 18:19:15 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142886272 Vs 18:19:15 Integrated Voltage Measurement... 18:19:46 Voltage Offset Correction: v_off_ini = 0.000000467 V, v_off_fin = -0.000002121 V 18:19:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142851044 Vs 18:19:47   Voltage Measurement, V = 0.000000 V 18:19:47 Temperature Measurement, Probe Number = 0, T = 22.337000 C 18:19:48 Temperature Measurement, Probe Number = 1, T = 22.955000 C 18:19:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.34 P2 = 3458_Meas_Junction, Value = 22.95 18:19:48 Integrated Voltage Measurement... 18:20:20 Voltage Offset Correction: v_off_ini = -0.000000812 V, v_off_fin = 0.000000773 V 18:20:20 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142880489 Vs 18:20:20 Integrated Voltage Measurement... 18:20:51 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = -0.000001817 V 18:20:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142864645 Vs 18:20:52   Voltage Measurement, V = 0.000000 V 18:20:52 Temperature Measurement, Probe Number = 0, T = 22.323000 C 18:20:53 Temperature Measurement, Probe Number = 1, T = 22.957000 C 18:20:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.32 P2 = 3458_Meas_Junction, Value = 22.96 18:20:53 Integrated Voltage Measurement... 18:21:25 Voltage Offset Correction: v_off_ini = -0.000000654 V, v_off_fin = 0.000000836 V 18:21:25 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142873642 Vs 18:21:25 Integrated Voltage Measurement... 18:21:59 Voltage Offset Correction: v_off_ini = 0.000000332 V, v_off_fin = -0.000001477 V 18:21:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142865524 Vs