SLAC Magnetic Measurements Date: 10-29-2020 Time: 16:25:17 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_019_Cell_45 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 16:25:34 Ambient Measurement Device(s) Being Used, type = None 16:25:34 Magnet Voltage Measurement Device(s) Being Used, type = None 16:25:35 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:25:35 XMAG Device(s) Being Used, type = None 16:25:35 Ambient Measurement Device(s) Being Used, type = None 16:25:37   Voltage Measurement, V = 0.000000 V 16:25:38 Temperature Measurement, Probe Number = 0, T = 21.616000 C 16:25:38 Temperature Measurement, Probe Number = 1, T = 22.640000 C 16:25:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 22.64 16:25:39 Integrated Voltage Measurement... 16:26:04 Voltage Offset Correction: v_off_ini = 0.000000147 V, v_off_fin = 0.000001000 V 16:26:04 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142937182 Vs 16:26:04 Integrated Voltage Measurement... 16:26:34 Voltage Offset Correction: v_off_ini = 0.000000572 V, v_off_fin = -0.000000937 V 16:26:34 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142868070 Vs 16:26:35   Voltage Measurement, V = 0.000000 V 16:26:36 Temperature Measurement, Probe Number = 0, T = 21.625000 C 16:26:37 Temperature Measurement, Probe Number = 1, T = 22.649000 C 16:26:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 22.65 16:26:37 Integrated Voltage Measurement... 16:27:08 Voltage Offset Correction: v_off_ini = -0.000000728 V, v_off_fin = -0.000000696 V 16:27:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142910720 Vs 16:27:08 Integrated Voltage Measurement... 16:27:37 Voltage Offset Correction: v_off_ini = 0.000000658 V, v_off_fin = -0.000002845 V 16:27:37 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142869752 Vs 16:27:38   Voltage Measurement, V = 0.000000 V 16:27:39 Temperature Measurement, Probe Number = 0, T = 21.646000 C 16:27:39 Temperature Measurement, Probe Number = 1, T = 22.650000 C 16:27:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.65 P2 = 3458_Meas_Junction, Value = 22.65 16:27:39 Integrated Voltage Measurement... 16:28:11 Voltage Offset Correction: v_off_ini = -0.000000700 V, v_off_fin = 0.000001060 V 16:28:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142908546 Vs 16:28:11 Integrated Voltage Measurement... 16:28:42 Voltage Offset Correction: v_off_ini = 0.000000860 V, v_off_fin = -0.000002023 V 16:28:42 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142860227 Vs 16:28:43   Voltage Measurement, V = 0.000000 V 16:28:44 Temperature Measurement, Probe Number = 0, T = 21.654000 C 16:28:45 Temperature Measurement, Probe Number = 1, T = 22.672000 C 16:28:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.65 P2 = 3458_Meas_Junction, Value = 22.67 16:28:45 Integrated Voltage Measurement... 16:29:15 Voltage Offset Correction: v_off_ini = -0.000000815 V, v_off_fin = 0.000000940 V 16:29:15 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142903961 Vs 16:29:15 Integrated Voltage Measurement... 16:29:45 Voltage Offset Correction: v_off_ini = 0.000000488 V, v_off_fin = -0.000002181 V 16:29:45 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142864293 Vs 16:29:46   Voltage Measurement, V = 0.000000 V 16:29:47 Temperature Measurement, Probe Number = 0, T = 21.671000 C 16:29:47 Temperature Measurement, Probe Number = 1, T = 22.689000 C 16:29:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.67 P2 = 3458_Meas_Junction, Value = 22.69 16:29:47 Integrated Voltage Measurement... 16:30:19 Voltage Offset Correction: v_off_ini = -0.000000671 V, v_off_fin = 0.000000506 V 16:30:19 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142908082 Vs 16:30:19 Integrated Voltage Measurement... 16:30:50 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = -0.000001741 V 16:30:50 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142858010 Vs 16:30:51   Voltage Measurement, V = 0.000000 V 16:30:51 Temperature Measurement, Probe Number = 0, T = 21.683000 C 16:30:52 Temperature Measurement, Probe Number = 1, T = 22.679000 C 16:30:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.68 P2 = 3458_Meas_Junction, Value = 22.68 16:30:52 Integrated Voltage Measurement... 16:31:23 Voltage Offset Correction: v_off_ini = -0.000000756 V, v_off_fin = 0.000000127 V 16:31:23 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142905304 Vs 16:31:23 Integrated Voltage Measurement... 16:31:54 Voltage Offset Correction: v_off_ini = 0.000000409 V, v_off_fin = -0.000003376 V 16:31:54 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142862217 Vs 16:31:55   Voltage Measurement, V = 0.000000 V 16:31:56 Temperature Measurement, Probe Number = 0, T = 21.696000 C 16:31:56 Temperature Measurement, Probe Number = 1, T = 22.676000 C 16:31:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.70 P2 = 3458_Meas_Junction, Value = 22.68 16:31:57 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = -0.000001011 V, v_off_fin = 0.000000323 V 16:32:27 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142906440 Vs 16:32:27 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 0.000000438 V, v_off_fin = -0.000001966 V 16:32:58 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142857026 Vs 16:32:59   Voltage Measurement, V = 0.000000 V 16:33:00 Temperature Measurement, Probe Number = 0, T = 21.710000 C 16:33:00 Temperature Measurement, Probe Number = 1, T = 22.677000 C 16:33:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.71 P2 = 3458_Meas_Junction, Value = 22.68 16:33:00 Integrated Voltage Measurement... 16:33:31 Voltage Offset Correction: v_off_ini = -0.000000628 V, v_off_fin = 0.000001557 V 16:33:31 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142902292 Vs 16:33:31 Integrated Voltage Measurement... 16:34:03 Voltage Offset Correction: v_off_ini = 0.000000110 V, v_off_fin = -0.000001958 V 16:34:03 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142867867 Vs 16:34:04   Voltage Measurement, V = 0.000000 V 16:34:05 Temperature Measurement, Probe Number = 0, T = 21.703000 C 16:34:05 Temperature Measurement, Probe Number = 1, T = 22.685000 C 16:34:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.70 P2 = 3458_Meas_Junction, Value = 22.68 16:34:05 Integrated Voltage Measurement... 16:34:36 Voltage Offset Correction: v_off_ini = -0.000000781 V, v_off_fin = 0.000000313 V 16:34:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142907385 Vs 16:34:36 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 0.000000485 V, v_off_fin = -0.000002567 V 16:35:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142859324 Vs 16:35:10   Voltage Measurement, V = 0.000000 V 16:35:10 Temperature Measurement, Probe Number = 0, T = 21.715000 C 16:35:11 Temperature Measurement, Probe Number = 1, T = 22.675000 C 16:35:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.71 P2 = 3458_Meas_Junction, Value = 22.68 16:35:11 Integrated Voltage Measurement... 16:35:43 Voltage Offset Correction: v_off_ini = -0.000000835 V, v_off_fin = 0.000000259 V 16:35:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142914396 Vs 16:35:43 Integrated Voltage Measurement... 16:36:15 Voltage Offset Correction: v_off_ini = 0.000000559 V, v_off_fin = -0.000002972 V 16:36:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142858187 Vs