SLAC Magnetic Measurements Date: 10-21-2020 Time: 14:58:37 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_019_Cell_45 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 14:58:55 Ambient Measurement Device(s) Being Used, type = None 14:58:55 Magnet Voltage Measurement Device(s) Being Used, type = None 14:58:55 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:58:55 XMAG Device(s) Being Used, type = None 14:58:55 Ambient Measurement Device(s) Being Used, type = None 14:59:07   Voltage Measurement, V = 0.000000 V 14:59:07 Temperature Measurement, Probe Number = 0, T = 21.639000 C 14:59:08 Temperature Measurement, Probe Number = 1, T = 20.570000 C 14:59:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.64 P2 = 3458_Meas_Junction, Value = 20.57 14:59:08 Integrated Voltage Measurement... 14:59:35 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = 0.000000071 V 14:59:35 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142937279 Vs 14:59:35 Integrated Voltage Measurement... 15:00:08 Voltage Offset Correction: v_off_ini = 0.000000037 V, v_off_fin = -0.000002943 V 15:00:08 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142902885 Vs 15:00:09   Voltage Measurement, V = 0.000000 V 15:00:09 Temperature Measurement, Probe Number = 0, T = 21.628000 C 15:00:10 Temperature Measurement, Probe Number = 1, T = 20.578000 C 15:00:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.63 P2 = 3458_Meas_Junction, Value = 20.58 15:00:10 Integrated Voltage Measurement... 15:00:41 Voltage Offset Correction: v_off_ini = -0.000001358 V, v_off_fin = 0.000000212 V 15:00:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142939129 Vs 15:00:41 Integrated Voltage Measurement... 15:01:14 Voltage Offset Correction: v_off_ini = -0.000000419 V, v_off_fin = -0.000002760 V 15:01:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142896040 Vs 15:01:15   Voltage Measurement, V = 0.000000 V 15:01:16 Temperature Measurement, Probe Number = 0, T = 21.634000 C 15:01:17 Temperature Measurement, Probe Number = 1, T = 20.583000 C 15:01:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.63 P2 = 3458_Meas_Junction, Value = 20.58 15:01:17 Integrated Voltage Measurement... 15:01:50 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000000106 V 15:01:50 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142930143 Vs 15:01:50 Integrated Voltage Measurement... 15:02:24 Voltage Offset Correction: v_off_ini = -0.000000196 V, v_off_fin = -0.000003197 V 15:02:24 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142887459 Vs 15:02:25   Voltage Measurement, V = 0.000000 V 15:02:26 Temperature Measurement, Probe Number = 0, T = 21.641000 C 15:02:26 Temperature Measurement, Probe Number = 1, T = 20.588000 C 15:02:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.64 P2 = 3458_Meas_Junction, Value = 20.59 15:02:26 Integrated Voltage Measurement... 15:02:58 Voltage Offset Correction: v_off_ini = -0.000001389 V, v_off_fin = 0.000000405 V 15:02:58 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142929607 Vs 15:02:58 Integrated Voltage Measurement... 15:03:38 Voltage Offset Correction: v_off_ini = -0.000000239 V, v_off_fin = -0.000001917 V 15:03:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142898638 Vs 15:03:39   Voltage Measurement, V = 0.000000 V 15:03:39 Temperature Measurement, Probe Number = 0, T = 21.656000 C 15:03:40 Temperature Measurement, Probe Number = 1, T = 20.596000 C 15:03:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.66 P2 = 3458_Meas_Junction, Value = 20.60 15:03:40 Integrated Voltage Measurement... 15:04:13 Voltage Offset Correction: v_off_ini = -0.000001190 V, v_off_fin = 0.000000034 V 15:04:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142929577 Vs 15:04:13 Integrated Voltage Measurement... 15:04:44 Voltage Offset Correction: v_off_ini = -0.000000219 V, v_off_fin = -0.000002534 V 15:04:44 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142897146 Vs 15:04:45   Voltage Measurement, V = 0.000000 V 15:04:45 Temperature Measurement, Probe Number = 0, T = 21.663000 C 15:04:46 Temperature Measurement, Probe Number = 1, T = 20.591000 C 15:04:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.66 P2 = 3458_Meas_Junction, Value = 20.59 15:04:46 Integrated Voltage Measurement... 15:05:18 Voltage Offset Correction: v_off_ini = -0.000001437 V, v_off_fin = -0.000000473 V 15:05:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142933013 Vs 15:05:18 Integrated Voltage Measurement... 15:05:50 Voltage Offset Correction: v_off_ini = -0.000000092 V, v_off_fin = -0.000002205 V 15:05:50 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142901223 Vs 15:05:51   Voltage Measurement, V = 0.000000 V 15:05:52 Temperature Measurement, Probe Number = 0, T = 21.661000 C 15:05:52 Temperature Measurement, Probe Number = 1, T = 20.593000 C 15:05:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.66 P2 = 3458_Meas_Junction, Value = 20.59 15:05:52 Integrated Voltage Measurement... 15:06:23 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000000151 V 15:06:23 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142932365 Vs 15:06:23 Integrated Voltage Measurement... 15:06:58 Voltage Offset Correction: v_off_ini = -0.000000150 V, v_off_fin = -0.000003552 V 15:06:58 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142894951 Vs 15:06:59   Voltage Measurement, V = 0.000000 V 15:07:00 Temperature Measurement, Probe Number = 0, T = 21.674000 C 15:07:00 Temperature Measurement, Probe Number = 1, T = 20.588000 C 15:07:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.67 P2 = 3458_Meas_Junction, Value = 20.59 15:07:00 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = -0.000001252 V, v_off_fin = 0.000000534 V 15:07:32 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142928230 Vs 15:07:32 Integrated Voltage Measurement... 15:08:02 Voltage Offset Correction: v_off_ini = -0.000000116 V, v_off_fin = -0.000002258 V 15:08:02 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142885739 Vs 15:08:03   Voltage Measurement, V = 0.000000 V 15:08:04 Temperature Measurement, Probe Number = 0, T = 21.681000 C 15:08:05 Temperature Measurement, Probe Number = 1, T = 20.589000 C 15:08:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.68 P2 = 3458_Meas_Junction, Value = 20.59 15:08:05 Integrated Voltage Measurement... 15:08:37 Voltage Offset Correction: v_off_ini = -0.000001242 V, v_off_fin = 0.000000118 V 15:08:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142935011 Vs 15:08:37 Integrated Voltage Measurement... 15:09:08 Voltage Offset Correction: v_off_ini = 0.000000095 V, v_off_fin = -0.000002063 V 15:09:08 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142891020 Vs 15:09:09   Voltage Measurement, V = 0.000000 V 15:09:09 Temperature Measurement, Probe Number = 0, T = 21.683000 C 15:09:10 Temperature Measurement, Probe Number = 1, T = 20.588000 C 15:09:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.68 P2 = 3458_Meas_Junction, Value = 20.59 15:09:10 Integrated Voltage Measurement... 15:09:42 Voltage Offset Correction: v_off_ini = -0.000001555 V, v_off_fin = 0.000000370 V 15:09:43 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142932264 Vs 15:09:43 Integrated Voltage Measurement... 15:10:14 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000002271 V 15:10:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142886781 Vs