SLAC Magnetic Measurements Date: 01-21-2021 Time: 09:22:16 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30_Upstairs Serial Number: PC33408 Run Number: 9 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch Full Set 9 09:22:34 Ambient Measurement Device(s) Being Used, type = None 09:22:34 Magnet Voltage Measurement Device(s) Being Used, type = None 09:22:34 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:22:34 XMAG Device(s) Being Used, type = None 09:22:34 Ambient Measurement Device(s) Being Used, type = None 09:22:49   Voltage Measurement, V = 0.000000 V 09:22:50 Temperature Measurement, Probe Number = 0, T = 23.577000 C 09:22:50 Temperature Measurement, Probe Number = 1, T = 24.215000 C 09:22:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.58 P2 = 3458_Meas_Junction, Value = 24.21 09:22:50 Integrated Voltage Measurement... 09:23:16 Voltage Offset Correction: v_off_ini = 0.000009981 V, v_off_fin = 0.000010886 V 09:23:17 Integrated Voltage Measurement Delta Gap = 0.0039994 m VT = 0.142271360 Vs 09:23:17 Integrated Voltage Measurement... 09:23:50 Voltage Offset Correction: v_off_ini = 0.000010466 V, v_off_fin = 0.000009045 V 09:23:50 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142299297 Vs 09:23:51   Voltage Measurement, V = 0.000000 V 09:23:52 Temperature Measurement, Probe Number = 0, T = 23.581000 C 09:23:52 Temperature Measurement, Probe Number = 1, T = 24.246000 C 09:23:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.58 P2 = 3458_Meas_Junction, Value = 24.25 09:23:52 Integrated Voltage Measurement... 09:24:28 Voltage Offset Correction: v_off_ini = 0.000009737 V, v_off_fin = 0.000011446 V 09:24:28 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142326179 Vs 09:24:28 Integrated Voltage Measurement... 09:25:00 Voltage Offset Correction: v_off_ini = 0.000010372 V, v_off_fin = 0.000008008 V 09:25:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142299164 Vs 09:25:01   Voltage Measurement, V = 0.000000 V 09:25:01 Temperature Measurement, Probe Number = 0, T = 23.580000 C 09:25:02 Temperature Measurement, Probe Number = 1, T = 24.245000 C 09:25:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.58 P2 = 3458_Meas_Junction, Value = 24.25 09:25:02 Integrated Voltage Measurement... 09:25:35 Voltage Offset Correction: v_off_ini = 0.000009448 V, v_off_fin = 0.000010580 V 09:25:35 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142319641 Vs 09:25:35 Integrated Voltage Measurement... 09:26:06 Voltage Offset Correction: v_off_ini = 0.000010671 V, v_off_fin = 0.000009010 V 09:26:06 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142300295 Vs 09:26:07   Voltage Measurement, V = 0.000000 V 09:26:07 Temperature Measurement, Probe Number = 0, T = 23.555000 C 09:26:08 Temperature Measurement, Probe Number = 1, T = 24.223000 C 09:26:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.22 09:26:08 Integrated Voltage Measurement... 09:26:39 Voltage Offset Correction: v_off_ini = 0.000009151 V, v_off_fin = 0.000010541 V 09:26:39 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142327287 Vs 09:26:39 Integrated Voltage Measurement... 09:27:10 Voltage Offset Correction: v_off_ini = 0.000010630 V, v_off_fin = 0.000008295 V 09:27:10 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142298998 Vs 09:27:11   Voltage Measurement, V = 0.000000 V 09:27:11 Temperature Measurement, Probe Number = 0, T = 23.558000 C 09:27:12 Temperature Measurement, Probe Number = 1, T = 24.223000 C 09:27:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.56 P2 = 3458_Meas_Junction, Value = 24.22 09:27:12 Integrated Voltage Measurement... 09:27:44 Voltage Offset Correction: v_off_ini = 0.000009099 V, v_off_fin = 0.000010404 V 09:27:44 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142320554 Vs 09:27:44 Integrated Voltage Measurement... 09:28:15 Voltage Offset Correction: v_off_ini = 0.000010463 V, v_off_fin = 0.000008628 V 09:28:15 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142295294 Vs 09:28:16   Voltage Measurement, V = 0.000000 V 09:28:17 Temperature Measurement, Probe Number = 0, T = 23.548000 C 09:28:17 Temperature Measurement, Probe Number = 1, T = 24.212000 C 09:28:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.21 09:28:17 Integrated Voltage Measurement... 09:28:48 Voltage Offset Correction: v_off_ini = 0.000009528 V, v_off_fin = 0.000010367 V 09:28:48 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142303834 Vs 09:28:48 Integrated Voltage Measurement... 09:29:19 Voltage Offset Correction: v_off_ini = 0.000010560 V, v_off_fin = 0.000008144 V 09:29:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142305268 Vs 09:29:20   Voltage Measurement, V = 0.000000 V 09:29:21 Temperature Measurement, Probe Number = 0, T = 23.543000 C 09:29:21 Temperature Measurement, Probe Number = 1, T = 24.225000 C 09:29:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.54 P2 = 3458_Meas_Junction, Value = 24.23 09:29:21 Integrated Voltage Measurement... 09:29:52 Voltage Offset Correction: v_off_ini = 0.000009137 V, v_off_fin = 0.000010519 V 09:29:52 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142325600 Vs 09:29:52 Integrated Voltage Measurement... 09:30:24 Voltage Offset Correction: v_off_ini = 0.000010473 V, v_off_fin = 0.000006937 V 09:30:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142306944 Vs 09:30:25   Voltage Measurement, V = 0.000000 V 09:30:26 Temperature Measurement, Probe Number = 0, T = 23.545000 C 09:30:26 Temperature Measurement, Probe Number = 1, T = 24.245000 C 09:30:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.25 09:30:26 Integrated Voltage Measurement... 09:31:25 Voltage Offset Correction: v_off_ini = 0.000010197 V, v_off_fin = 0.000011310 V 09:31:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142331597 Vs 09:31:25 Integrated Voltage Measurement... 09:32:01 Voltage Offset Correction: v_off_ini = 0.000010474 V, v_off_fin = 0.000007343 V 09:32:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142307264 Vs 09:32:02   Voltage Measurement, V = 0.000000 V 09:32:02 Temperature Measurement, Probe Number = 0, T = 23.545000 C 09:32:03 Temperature Measurement, Probe Number = 1, T = 24.244000 C 09:32:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.24 09:32:03 Integrated Voltage Measurement... 09:32:33 Voltage Offset Correction: v_off_ini = 0.000009457 V, v_off_fin = 0.000010822 V 09:32:33 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142315534 Vs 09:32:33 Integrated Voltage Measurement... 09:33:05 Voltage Offset Correction: v_off_ini = 0.000010570 V, v_off_fin = 0.000008607 V 09:33:05 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142299567 Vs 09:33:06   Voltage Measurement, V = 0.000000 V 09:33:07 Temperature Measurement, Probe Number = 0, T = 23.550000 C 09:33:07 Temperature Measurement, Probe Number = 1, T = 24.254000 C 09:33:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.25 09:33:07 Integrated Voltage Measurement... 09:33:40 Voltage Offset Correction: v_off_ini = 0.000009241 V, v_off_fin = 0.000011298 V 09:33:40 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142317879 Vs 09:33:40 Integrated Voltage Measurement... 09:34:10 Voltage Offset Correction: v_off_ini = 0.000010578 V, v_off_fin = 0.000006176 V 09:34:10 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142301375 Vs