SLAC Magnetic Measurements Date: 10-28-2020 Time: 15:35:02 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30_Upstairs Serial Number: PC33408 Run Number: 5 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 5 15:35:20 Ambient Measurement Device(s) Being Used, type = None 15:35:20 Magnet Voltage Measurement Device(s) Being Used, type = None 15:35:21 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:35:21 XMAG Device(s) Being Used, type = None 15:35:21 Ambient Measurement Device(s) Being Used, type = None 15:35:24   Voltage Measurement, V = 0.000000 V 15:35:25 Temperature Measurement, Probe Number = 0, T = 41.882000 C 15:35:25 Temperature Measurement, Probe Number = 1, T = 24.950000 C 15:35:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.88 P2 = 3458_Meas_Junction, Value = 24.95 15:35:25 Integrated Voltage Measurement... 15:35:52 Voltage Offset Correction: v_off_ini = 0.000011171 V, v_off_fin = 0.000011389 V 15:35:52 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142324485 Vs 15:35:52 Integrated Voltage Measurement... 15:36:30 Voltage Offset Correction: v_off_ini = 0.000011148 V, v_off_fin = -0.018774828 V 15:36:30 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.088114776 Vs 15:36:31   Voltage Measurement, V = 0.000000 V 15:36:32 Temperature Measurement, Probe Number = 0, T = 41.835000 C 15:36:33 Temperature Measurement, Probe Number = 1, T = 24.956000 C 15:36:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.84 P2 = 3458_Meas_Junction, Value = 24.96 15:36:33 Integrated Voltage Measurement... 15:37:30 Voltage Offset Correction: v_off_ini = 0.000010204 V, v_off_fin = 0.000010847 V 15:37:30 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142304205 Vs 15:37:30 Integrated Voltage Measurement... 15:38:03 Voltage Offset Correction: v_off_ini = 0.000011115 V, v_off_fin = 0.000008739 V 15:38:03 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142282400 Vs 15:38:04   Voltage Measurement, V = 0.000000 V 15:38:04 Temperature Measurement, Probe Number = 0, T = 41.827000 C 15:38:05 Temperature Measurement, Probe Number = 1, T = 24.965000 C 15:38:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.83 P2 = 3458_Meas_Junction, Value = 24.96 15:38:05 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = 0.000010526 V, v_off_fin = 0.000012988 V 15:38:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142311848 Vs 15:38:51 Integrated Voltage Measurement... 15:39:23 Voltage Offset Correction: v_off_ini = 0.000011324 V, v_off_fin = 0.000009187 V 15:39:23 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142276884 Vs 15:39:24   Voltage Measurement, V = 0.000000 V 15:39:24 Temperature Measurement, Probe Number = 0, T = 41.829000 C 15:39:25 Temperature Measurement, Probe Number = 1, T = 24.991000 C 15:39:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.83 P2 = 3458_Meas_Junction, Value = 24.99 15:39:25 Integrated Voltage Measurement... 15:39:57 Voltage Offset Correction: v_off_ini = 0.000010402 V, v_off_fin = 0.000011454 V 15:39:57 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142297941 Vs 15:39:57 Integrated Voltage Measurement... 15:40:28 Voltage Offset Correction: v_off_ini = 0.000011675 V, v_off_fin = 0.000008805 V 15:40:28 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142272028 Vs 15:40:29   Voltage Measurement, V = 0.000000 V 15:40:30 Temperature Measurement, Probe Number = 0, T = 41.847000 C 15:40:31 Temperature Measurement, Probe Number = 1, T = 24.969000 C 15:40:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.85 P2 = 3458_Meas_Junction, Value = 24.97 15:40:31 Integrated Voltage Measurement... 15:41:12 Voltage Offset Correction: v_off_ini = 0.000010465 V, v_off_fin = 0.000012133 V 15:41:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142309298 Vs 15:41:12 Integrated Voltage Measurement... 15:42:46 Voltage Offset Correction: v_off_ini = 0.000011658 V, v_off_fin = 0.000009154 V 15:42:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142286204 Vs 15:42:47   Voltage Measurement, V = 0.000000 V 15:42:47 Temperature Measurement, Probe Number = 0, T = 41.870000 C 15:42:48 Temperature Measurement, Probe Number = 1, T = 24.974000 C 15:42:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.87 P2 = 3458_Meas_Junction, Value = 24.97 15:42:48 Integrated Voltage Measurement... 15:43:25 Voltage Offset Correction: v_off_ini = 0.000010380 V, v_off_fin = 0.000010726 V 15:43:26 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142296959 Vs 15:43:26 Integrated Voltage Measurement... 15:43:59 Voltage Offset Correction: v_off_ini = 0.000011391 V, v_off_fin = 0.000009804 V 15:43:59 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142279153 Vs 15:44:00   Voltage Measurement, V = 0.000000 V 15:44:01 Temperature Measurement, Probe Number = 0, T = 41.864000 C 15:44:01 Temperature Measurement, Probe Number = 1, T = 24.970000 C 15:44:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.86 P2 = 3458_Meas_Junction, Value = 24.97 15:44:01 Integrated Voltage Measurement... 15:44:35 Voltage Offset Correction: v_off_ini = 0.000010322 V, v_off_fin = 0.000012576 V 15:44:35 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142311489 Vs 15:44:35 Integrated Voltage Measurement... 15:45:05 Voltage Offset Correction: v_off_ini = 0.000011017 V, v_off_fin = 0.000009208 V 15:45:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142279666 Vs 15:45:06   Voltage Measurement, V = 0.000000 V 15:45:07 Temperature Measurement, Probe Number = 0, T = 41.856000 C 15:45:08 Temperature Measurement, Probe Number = 1, T = 24.978000 C 15:45:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.86 P2 = 3458_Meas_Junction, Value = 24.98 15:45:08 Integrated Voltage Measurement... 15:45:43 Voltage Offset Correction: v_off_ini = 0.000009724 V, v_off_fin = 0.000010919 V 15:45:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142303409 Vs 15:45:43 Integrated Voltage Measurement... 15:46:15 Voltage Offset Correction: v_off_ini = 0.000010750 V, v_off_fin = 0.000009103 V 15:46:15 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142273178 Vs 15:46:16   Voltage Measurement, V = 0.000000 V 15:46:17 Temperature Measurement, Probe Number = 0, T = 41.857000 C 15:46:17 Temperature Measurement, Probe Number = 1, T = 24.994000 C 15:46:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.86 P2 = 3458_Meas_Junction, Value = 24.99 15:46:17 Integrated Voltage Measurement... 15:46:49 Voltage Offset Correction: v_off_ini = 0.000009698 V, v_off_fin = 0.000011132 V 15:46:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142313991 Vs 15:46:49 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 0.000011119 V, v_off_fin = 0.000008433 V 15:47:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142278664 Vs 15:47:21   Voltage Measurement, V = 0.000000 V 15:47:21 Temperature Measurement, Probe Number = 0, T = 41.853000 C 15:47:22 Temperature Measurement, Probe Number = 1, T = 24.991000 C 15:47:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.85 P2 = 3458_Meas_Junction, Value = 24.99 15:47:22 Integrated Voltage Measurement... 15:47:54 Voltage Offset Correction: v_off_ini = 0.000009519 V, v_off_fin = 0.000010880 V 15:47:54 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142314504 Vs 15:47:54 Integrated Voltage Measurement... 15:48:26 Voltage Offset Correction: v_off_ini = 0.000011087 V, v_off_fin = 0.000008605 V 15:48:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142291555 Vs