SLAC Magnetic Measurements Date: 09-09-2020 Time: 22:38:52 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 22:38:55 Ambient Measurement Device(s) Being Used, type = None 22:38:55 Magnet Voltage Measurement Device(s) Being Used, type = None 22:38:56 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 22:38:56 XMAG Device(s) Being Used, type = None 22:38:56 Ambient Measurement Device(s) Being Used, type = None 22:38:58   Voltage Measurement, V = 0.000000 V 22:38:59 Temperature Measurement, Probe Number = 0, T = 23.086000 C 22:39:00 Temperature Measurement, Probe Number = 1, T = 23.730000 C 22:39:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.09 P2 = 3458_Meas_Junction, Value = 23.73 22:39:00 Integrated Voltage Measurement... 22:39:35 Voltage Offset Correction: v_off_ini = -0.000001835 V, v_off_fin = -0.000003637 V 22:39:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142287236 Vs 22:39:35 Integrated Voltage Measurement... 22:40:07 Voltage Offset Correction: v_off_ini = -0.000002813 V, v_off_fin = -0.000001718 V 22:40:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.142279713 Vs 22:40:08   Voltage Measurement, V = 0.000000 V 22:40:09 Temperature Measurement, Probe Number = 0, T = 23.102000 C 22:40:09 Temperature Measurement, Probe Number = 1, T = 23.741000 C 22:40:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.10 P2 = 3458_Meas_Junction, Value = 23.74 22:40:09 Integrated Voltage Measurement... 22:40:42 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000002539 V 22:40:42 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142297072 Vs 22:40:42 Integrated Voltage Measurement... 22:41:14 Voltage Offset Correction: v_off_ini = -0.000003001 V, v_off_fin = -0.000001369 V 22:41:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.142268717 Vs 22:41:15   Voltage Measurement, V = 0.000000 V 22:41:16 Temperature Measurement, Probe Number = 0, T = 23.135000 C 22:41:16 Temperature Measurement, Probe Number = 1, T = 23.771000 C 22:41:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.14 P2 = 3458_Meas_Junction, Value = 23.77 22:41:16 Integrated Voltage Measurement... 22:41:48 Voltage Offset Correction: v_off_ini = -0.000002171 V, v_off_fin = -0.000003830 V 22:41:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142286581 Vs 22:41:48 Integrated Voltage Measurement... 22:42:20 Voltage Offset Correction: v_off_ini = -0.000002854 V, v_off_fin = -0.000001023 V 22:42:20 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.142277014 Vs 22:42:21   Voltage Measurement, V = 0.000000 V 22:42:22 Temperature Measurement, Probe Number = 0, T = 23.170000 C 22:42:22 Temperature Measurement, Probe Number = 1, T = 23.810000 C 22:42:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.17 P2 = 3458_Meas_Junction, Value = 23.81 22:42:22 Integrated Voltage Measurement... 22:42:55 Voltage Offset Correction: v_off_ini = -0.000002040 V, v_off_fin = -0.000002973 V 22:42:55 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142286664 Vs 22:42:55 Integrated Voltage Measurement... 22:43:27 Voltage Offset Correction: v_off_ini = -0.000003140 V, v_off_fin = -0.000001348 V 22:43:27 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.142278165 Vs 22:43:28   Voltage Measurement, V = 0.000000 V 22:43:28 Temperature Measurement, Probe Number = 0, T = 23.203000 C 22:43:29 Temperature Measurement, Probe Number = 1, T = 23.845000 C 22:43:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.20 P2 = 3458_Meas_Junction, Value = 23.84 22:43:29 Integrated Voltage Measurement... 22:44:01 Voltage Offset Correction: v_off_ini = -0.000002003 V, v_off_fin = -0.000002770 V 22:44:01 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142287662 Vs 22:44:01 Integrated Voltage Measurement... 22:44:35 Voltage Offset Correction: v_off_ini = -0.000003252 V, v_off_fin = -0.000002397 V 22:44:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = 0.142282016 Vs 22:44:36   Voltage Measurement, V = 0.000000 V 22:44:36 Temperature Measurement, Probe Number = 0, T = 23.232000 C 22:44:37 Temperature Measurement, Probe Number = 1, T = 23.869000 C 22:44:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.23 P2 = 3458_Meas_Junction, Value = 23.87 22:44:37 Integrated Voltage Measurement... 22:45:13 Voltage Offset Correction: v_off_ini = -0.000002160 V, v_off_fin = -0.000003472 V 22:45:13 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = -0.142285518 Vs 22:45:13 Integrated Voltage Measurement... 22:45:46 Voltage Offset Correction: v_off_ini = -0.000003087 V, v_off_fin = -0.000002535 V 22:45:46 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.142277514 Vs 22:45:47   Voltage Measurement, V = 0.000000 V 22:45:48 Temperature Measurement, Probe Number = 0, T = 23.268000 C 22:45:48 Temperature Measurement, Probe Number = 1, T = 23.919000 C 22:45:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.27 P2 = 3458_Meas_Junction, Value = 23.92 22:45:48 Integrated Voltage Measurement... 22:46:26 Voltage Offset Correction: v_off_ini = -0.000002306 V, v_off_fin = -0.000004057 V 22:46:26 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142292858 Vs 22:46:26 Integrated Voltage Measurement... 22:47:00 Voltage Offset Correction: v_off_ini = -0.000003130 V, v_off_fin = -0.000001791 V 22:47:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = 0.142276969 Vs 22:47:01   Voltage Measurement, V = 0.000000 V 22:47:02 Temperature Measurement, Probe Number = 0, T = 23.300000 C 22:47:02 Temperature Measurement, Probe Number = 1, T = 23.966000 C 22:47:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.30 P2 = 3458_Meas_Junction, Value = 23.97 22:47:02 Integrated Voltage Measurement... 22:47:37 Voltage Offset Correction: v_off_ini = -0.000002097 V, v_off_fin = -0.000003945 V 22:47:37 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142292290 Vs 22:47:37 Integrated Voltage Measurement... 22:48:10 Voltage Offset Correction: v_off_ini = -0.000003053 V, v_off_fin = -0.000000813 V 22:48:10 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = 0.142281499 Vs 22:48:11   Voltage Measurement, V = 0.000000 V 22:48:12 Temperature Measurement, Probe Number = 0, T = 23.332000 C 22:48:13 Temperature Measurement, Probe Number = 1, T = 23.993000 C 22:48:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.33 P2 = 3458_Meas_Junction, Value = 23.99 22:48:13 Integrated Voltage Measurement... 22:48:46 Voltage Offset Correction: v_off_ini = -0.000002090 V, v_off_fin = -0.000002484 V 22:48:46 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142292837 Vs 22:48:46 Integrated Voltage Measurement... 22:49:18 Voltage Offset Correction: v_off_ini = -0.000003133 V, v_off_fin = -0.000002263 V 22:49:18 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.142277866 Vs 22:49:19   Voltage Measurement, V = 0.000000 V 22:49:20 Temperature Measurement, Probe Number = 0, T = 23.359000 C 22:49:20 Temperature Measurement, Probe Number = 1, T = 24.028000 C 22:49:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.36 P2 = 3458_Meas_Junction, Value = 24.03 22:49:20 Integrated Voltage Measurement... 22:49:52 Voltage Offset Correction: v_off_ini = -0.000002174 V, v_off_fin = -0.000004594 V 22:49:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142293074 Vs 22:49:52 Integrated Voltage Measurement... 22:50:24 Voltage Offset Correction: v_off_ini = -0.000003151 V, v_off_fin = -0.000002237 V 22:50:25 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.142285895 Vs