SLAC Magnetic Measurements Date: 10-28-2020 Time: 15:59:10 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30_Upstairs Serial Number: PC33408 Run Number: 6 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch with 213 closed instead of 212. Full Set 5 15:59:29 Ambient Measurement Device(s) Being Used, type = None 15:59:29 Magnet Voltage Measurement Device(s) Being Used, type = None 15:59:29 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:59:29 XMAG Device(s) Being Used, type = None 15:59:29 Ambient Measurement Device(s) Being Used, type = None 15:59:46   Voltage Measurement, V = 0.000000 V 15:59:46 Temperature Measurement, Probe Number = 0, T = 41.840000 C 15:59:47 Temperature Measurement, Probe Number = 1, T = 24.908000 C 15:59:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.84 P2 = 3458_Meas_Junction, Value = 24.91 15:59:47 Integrated Voltage Measurement... 16:00:15 Voltage Offset Correction: v_off_ini = 0.000011038 V, v_off_fin = 0.000011627 V 16:00:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142289559 Vs 16:00:15 Integrated Voltage Measurement... 16:00:51 Voltage Offset Correction: v_off_ini = 0.000011762 V, v_off_fin = 0.000009218 V 16:00:51 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142274757 Vs 16:00:52   Voltage Measurement, V = 0.000000 V 16:00:53 Temperature Measurement, Probe Number = 0, T = 41.818000 C 16:00:53 Temperature Measurement, Probe Number = 1, T = 24.915000 C 16:00:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.82 P2 = 3458_Meas_Junction, Value = 24.91 16:00:53 Integrated Voltage Measurement... 16:01:40 Voltage Offset Correction: v_off_ini = 0.000010836 V, v_off_fin = 0.000011412 V 16:01:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142327682 Vs 16:01:40 Integrated Voltage Measurement... 16:02:22 Voltage Offset Correction: v_off_ini = 0.000011484 V, v_off_fin = 0.000008812 V 16:02:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142288337 Vs 16:02:23   Voltage Measurement, V = 0.000000 V 16:02:24 Temperature Measurement, Probe Number = 0, T = 41.825000 C 16:02:25 Temperature Measurement, Probe Number = 1, T = 24.920000 C 16:02:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.83 P2 = 3458_Meas_Junction, Value = 24.92 16:02:25 Integrated Voltage Measurement... 16:02:58 Voltage Offset Correction: v_off_ini = 0.000010363 V, v_off_fin = 0.000012817 V 16:02:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142321122 Vs 16:02:58 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = 0.000011822 V, v_off_fin = 0.000009705 V 16:03:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142302314 Vs 16:03:32   Voltage Measurement, V = 0.000000 V 16:03:33 Temperature Measurement, Probe Number = 0, T = 41.838000 C 16:03:33 Temperature Measurement, Probe Number = 1, T = 24.919000 C 16:03:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.84 P2 = 3458_Meas_Junction, Value = 24.92 16:03:33 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = 0.000010646 V, v_off_fin = 0.000012451 V 16:04:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142318656 Vs 16:04:08 Integrated Voltage Measurement... 16:04:40 Voltage Offset Correction: v_off_ini = 0.000011634 V, v_off_fin = 0.000009378 V 16:04:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142286527 Vs 16:04:41   Voltage Measurement, V = 0.000000 V 16:04:42 Temperature Measurement, Probe Number = 0, T = 41.830000 C 16:04:43 Temperature Measurement, Probe Number = 1, T = 24.927000 C 16:04:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.83 P2 = 3458_Meas_Junction, Value = 24.93 16:04:43 Integrated Voltage Measurement... 16:05:14 Voltage Offset Correction: v_off_ini = 0.000010048 V, v_off_fin = 0.000012137 V 16:05:14 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142312238 Vs 16:05:14 Integrated Voltage Measurement... 16:05:47 Voltage Offset Correction: v_off_ini = 0.000011203 V, v_off_fin = 0.000008109 V 16:05:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142291697 Vs 16:05:48   Voltage Measurement, V = 0.000000 V 16:05:48 Temperature Measurement, Probe Number = 0, T = 41.806000 C 16:05:49 Temperature Measurement, Probe Number = 1, T = 24.888000 C 16:05:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.81 P2 = 3458_Meas_Junction, Value = 24.89 16:05:49 Integrated Voltage Measurement... 16:06:23 Voltage Offset Correction: v_off_ini = 0.000009572 V, v_off_fin = 0.000010866 V 16:06:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142319318 Vs 16:06:23 Integrated Voltage Measurement... 16:07:05 Voltage Offset Correction: v_off_ini = 0.000010259 V, v_off_fin = 0.000010492 V 16:07:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142289032 Vs 16:07:06   Voltage Measurement, V = 0.000000 V 16:07:06 Temperature Measurement, Probe Number = 0, T = 41.771000 C 16:07:07 Temperature Measurement, Probe Number = 1, T = 24.888000 C 16:07:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.77 P2 = 3458_Meas_Junction, Value = 24.89 16:07:07 Integrated Voltage Measurement... 16:07:38 Voltage Offset Correction: v_off_ini = 0.000009279 V, v_off_fin = 0.000009962 V 16:07:38 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142286002 Vs 16:07:38 Integrated Voltage Measurement... 16:08:11 Voltage Offset Correction: v_off_ini = 0.000009634 V, v_off_fin = 0.000007815 V 16:08:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142290693 Vs 16:08:12   Voltage Measurement, V = 0.000000 V 16:08:12 Temperature Measurement, Probe Number = 0, T = 41.740000 C 16:08:13 Temperature Measurement, Probe Number = 1, T = 24.890000 C 16:08:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.74 P2 = 3458_Meas_Junction, Value = 24.89 16:08:13 Integrated Voltage Measurement... 16:08:47 Voltage Offset Correction: v_off_ini = 0.000008681 V, v_off_fin = 0.000010253 V 16:08:47 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142309724 Vs 16:08:47 Integrated Voltage Measurement... 16:09:27 Voltage Offset Correction: v_off_ini = 0.000009715 V, v_off_fin = 0.000008038 V 16:09:27 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142283716 Vs 16:09:28   Voltage Measurement, V = 0.000000 V 16:09:29 Temperature Measurement, Probe Number = 0, T = 41.724000 C 16:09:29 Temperature Measurement, Probe Number = 1, T = 24.897000 C 16:09:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.72 P2 = 3458_Meas_Junction, Value = 24.90 16:09:29 Integrated Voltage Measurement... 16:10:02 Voltage Offset Correction: v_off_ini = 0.000008782 V, v_off_fin = 0.000010982 V 16:10:02 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142317925 Vs 16:10:02 Integrated Voltage Measurement... 16:10:33 Voltage Offset Correction: v_off_ini = 0.000009915 V, v_off_fin = 0.000006672 V 16:10:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142290063 Vs 16:10:34   Voltage Measurement, V = 0.000000 V 16:10:35 Temperature Measurement, Probe Number = 0, T = 41.726000 C 16:10:35 Temperature Measurement, Probe Number = 1, T = 24.913000 C 16:10:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 41.73 P2 = 3458_Meas_Junction, Value = 24.91 16:10:35 Integrated Voltage Measurement... 16:11:06 Voltage Offset Correction: v_off_ini = 0.000008352 V, v_off_fin = 0.000010246 V 16:11:06 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142314951 Vs 16:11:06 Integrated Voltage Measurement... 16:11:38 Voltage Offset Correction: v_off_ini = 0.000009906 V, v_off_fin = 0.000007520 V 16:11:38 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142294486 Vs