SLAC Magnetic Measurements Date: 01-07-2021 Time: 11:48:14 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 11:48:31 Ambient Measurement Device(s) Being Used, type = None 11:48:31 Magnet Voltage Measurement Device(s) Being Used, type = None 11:48:32 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:48:32 XMAG Device(s) Being Used, type = None 11:48:32 Ambient Measurement Device(s) Being Used, type = None 11:48:38   Voltage Measurement, V = 0.000000 V 11:48:38 Temperature Measurement, Probe Number = 0, T = 20.590000 C 11:48:39 Temperature Measurement, Probe Number = 1, T = 21.584000 C 11:48:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.59 P2 = 3458_Meas_Junction, Value = 21.58 11:48:39 Integrated Voltage Measurement... 11:49:05 Voltage Offset Correction: v_off_ini = 0.000000224 V, v_off_fin = 0.000000468 V 11:49:05 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142337620 Vs 11:49:05 Integrated Voltage Measurement... 11:49:59 Voltage Offset Correction: v_off_ini = 0.000000515 V, v_off_fin = -0.000001021 V 11:49:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142337471 Vs 11:50:00   Voltage Measurement, V = 0.000000 V 11:50:01 Temperature Measurement, Probe Number = 0, T = 20.586000 C 11:50:01 Temperature Measurement, Probe Number = 1, T = 21.576000 C 11:50:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.59 P2 = 3458_Meas_Junction, Value = 21.58 11:50:01 Integrated Voltage Measurement... 11:50:40 Voltage Offset Correction: v_off_ini = -0.000000316 V, v_off_fin = 0.000001368 V 11:50:40 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142365099 Vs 11:50:40 Integrated Voltage Measurement... 11:51:10 Voltage Offset Correction: v_off_ini = 0.000000746 V, v_off_fin = -0.000001717 V 11:51:10 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142328070 Vs 11:51:11   Voltage Measurement, V = 0.000000 V 11:51:12 Temperature Measurement, Probe Number = 0, T = 20.593000 C 11:51:12 Temperature Measurement, Probe Number = 1, T = 21.528000 C 11:51:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.59 P2 = 3458_Meas_Junction, Value = 21.53 11:51:12 Integrated Voltage Measurement... 11:51:45 Voltage Offset Correction: v_off_ini = -0.000000450 V, v_off_fin = 0.000000531 V 11:51:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142362457 Vs 11:51:45 Integrated Voltage Measurement... 11:52:15 Voltage Offset Correction: v_off_ini = 0.000000810 V, v_off_fin = -0.000001549 V 11:52:15 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142333607 Vs 11:52:16   Voltage Measurement, V = 0.000000 V 11:52:17 Temperature Measurement, Probe Number = 0, T = 20.598000 C 11:52:18 Temperature Measurement, Probe Number = 1, T = 21.520000 C 11:52:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.60 P2 = 3458_Meas_Junction, Value = 21.52 11:52:18 Integrated Voltage Measurement... 11:52:49 Voltage Offset Correction: v_off_ini = -0.000000455 V, v_off_fin = 0.000000810 V 11:52:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142356802 Vs 11:52:49 Integrated Voltage Measurement... 11:53:20 Voltage Offset Correction: v_off_ini = 0.000000992 V, v_off_fin = -0.000001230 V 11:53:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142331122 Vs 11:53:21   Voltage Measurement, V = 0.000000 V 11:53:22 Temperature Measurement, Probe Number = 0, T = 20.598000 C 11:53:22 Temperature Measurement, Probe Number = 1, T = 21.494000 C 11:53:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.60 P2 = 3458_Meas_Junction, Value = 21.49 11:53:22 Integrated Voltage Measurement... 11:53:56 Voltage Offset Correction: v_off_ini = -0.000000029 V, v_off_fin = 0.000001081 V 11:53:56 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142359586 Vs 11:53:56 Integrated Voltage Measurement... 11:54:27 Voltage Offset Correction: v_off_ini = 0.000000761 V, v_off_fin = -0.000002309 V 11:54:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142350169 Vs 11:54:28   Voltage Measurement, V = 0.000000 V 11:54:28 Temperature Measurement, Probe Number = 0, T = 20.584000 C 11:54:29 Temperature Measurement, Probe Number = 1, T = 21.485000 C 11:54:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.58 P2 = 3458_Meas_Junction, Value = 21.48 11:54:29 Integrated Voltage Measurement... 11:55:00 Voltage Offset Correction: v_off_ini = -0.000000455 V, v_off_fin = 0.000002016 V 11:55:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142351384 Vs 11:55:00 Integrated Voltage Measurement... 11:55:31 Voltage Offset Correction: v_off_ini = 0.000000731 V, v_off_fin = -0.000001935 V 11:55:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142325540 Vs 11:55:32   Voltage Measurement, V = 0.000000 V 11:55:33 Temperature Measurement, Probe Number = 0, T = 20.580000 C 11:55:33 Temperature Measurement, Probe Number = 1, T = 21.504000 C 11:55:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.58 P2 = 3458_Meas_Junction, Value = 21.50 11:55:33 Integrated Voltage Measurement... 11:57:22 Voltage Offset Correction: v_off_ini = 0.000000444 V, v_off_fin = 0.000001619 V 11:57:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142373058 Vs 11:57:22 Integrated Voltage Measurement... 11:58:01 Voltage Offset Correction: v_off_ini = 0.000000509 V, v_off_fin = -0.000001544 V 11:58:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142340040 Vs 11:58:02   Voltage Measurement, V = 0.000000 V 11:58:03 Temperature Measurement, Probe Number = 0, T = 20.544000 C 11:58:03 Temperature Measurement, Probe Number = 1, T = 21.512000 C 11:58:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.54 P2 = 3458_Meas_Junction, Value = 21.51 11:58:03 Integrated Voltage Measurement... 11:58:37 Voltage Offset Correction: v_off_ini = -0.000000297 V, v_off_fin = 0.000002154 V 11:58:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142354982 Vs 11:58:37 Integrated Voltage Measurement... 11:59:08 Voltage Offset Correction: v_off_ini = 0.000000367 V, v_off_fin = -0.000002655 V 11:59:08 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142327767 Vs 11:59:09   Voltage Measurement, V = 0.000000 V 11:59:10 Temperature Measurement, Probe Number = 0, T = 20.556000 C 11:59:11 Temperature Measurement, Probe Number = 1, T = 21.490000 C 11:59:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.56 P2 = 3458_Meas_Junction, Value = 21.49 11:59:11 Integrated Voltage Measurement... 11:59:41 Voltage Offset Correction: v_off_ini = -0.000000347 V, v_off_fin = 0.000000581 V 11:59:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142366366 Vs 11:59:41 Integrated Voltage Measurement... 12:00:13 Voltage Offset Correction: v_off_ini = 0.000000755 V, v_off_fin = -0.000002432 V 12:00:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142336106 Vs 12:00:14   Voltage Measurement, V = 0.000000 V 12:00:15 Temperature Measurement, Probe Number = 0, T = 20.565000 C 12:00:15 Temperature Measurement, Probe Number = 1, T = 21.515000 C 12:00:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.57 P2 = 3458_Meas_Junction, Value = 21.52 12:00:15 Integrated Voltage Measurement... 12:00:46 Voltage Offset Correction: v_off_ini = -0.000000431 V, v_off_fin = 0.000001428 V 12:00:46 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142355052 Vs 12:00:46 Integrated Voltage Measurement... 12:01:18 Voltage Offset Correction: v_off_ini = 0.000000667 V, v_off_fin = -0.000001404 V 12:01:18 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142326280 Vs