SLAC Magnetic Measurements Date: 12-02-2020 Time: 13:24:27 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_018_Cell_30 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 13:24:44 Ambient Measurement Device(s) Being Used, type = None 13:24:44 Magnet Voltage Measurement Device(s) Being Used, type = None 13:24:45 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:24:45 XMAG Device(s) Being Used, type = None 13:24:45 Ambient Measurement Device(s) Being Used, type = None 13:24:46   Voltage Measurement, V = 0.000000 V 13:24:47 Temperature Measurement, Probe Number = 0, T = 20.757000 C 13:24:48 Temperature Measurement, Probe Number = 1, T = 22.327000 C 13:24:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 22.33 13:24:48 Integrated Voltage Measurement... 13:25:14 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000001839 V 13:25:14 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142309940 Vs 13:25:14 Integrated Voltage Measurement... 13:25:49 Voltage Offset Correction: v_off_ini = 0.000001077 V, v_off_fin = -0.000001537 V 13:25:50 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142275717 Vs 13:25:51   Voltage Measurement, V = 0.000000 V 13:25:51 Temperature Measurement, Probe Number = 0, T = 20.755000 C 13:25:52 Temperature Measurement, Probe Number = 1, T = 22.338000 C 13:25:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.75 P2 = 3458_Meas_Junction, Value = 22.34 13:25:52 Integrated Voltage Measurement... 13:26:27 Voltage Offset Correction: v_off_ini = 0.000000224 V, v_off_fin = 0.000001615 V 13:26:27 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142304798 Vs 13:26:27 Integrated Voltage Measurement... 13:26:58 Voltage Offset Correction: v_off_ini = 0.000000822 V, v_off_fin = -0.000001888 V 13:26:58 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142302412 Vs 13:26:59   Voltage Measurement, V = 0.000000 V 13:27:00 Temperature Measurement, Probe Number = 0, T = 20.796000 C 13:27:00 Temperature Measurement, Probe Number = 1, T = 22.384000 C 13:27:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 22.38 13:27:00 Integrated Voltage Measurement... 13:27:39 Voltage Offset Correction: v_off_ini = -0.000000202 V, v_off_fin = 0.000001134 V 13:27:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142328529 Vs 13:27:39 Integrated Voltage Measurement... 13:28:11 Voltage Offset Correction: v_off_ini = 0.000000829 V, v_off_fin = -0.000001931 V 13:28:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142296166 Vs 13:28:12   Voltage Measurement, V = 0.000000 V 13:28:13 Temperature Measurement, Probe Number = 0, T = 20.822000 C 13:28:14 Temperature Measurement, Probe Number = 1, T = 22.391000 C 13:28:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 22.39 13:28:14 Integrated Voltage Measurement... 13:28:46 Voltage Offset Correction: v_off_ini = -0.000000193 V, v_off_fin = 0.000001534 V 13:28:46 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142315317 Vs 13:28:46 Integrated Voltage Measurement... 13:29:24 Voltage Offset Correction: v_off_ini = 0.000000741 V, v_off_fin = -0.000001911 V 13:29:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142293199 Vs 13:29:25   Voltage Measurement, V = 0.000000 V 13:29:25 Temperature Measurement, Probe Number = 0, T = 20.847000 C 13:29:26 Temperature Measurement, Probe Number = 1, T = 22.423000 C 13:29:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.85 P2 = 3458_Meas_Junction, Value = 22.42 13:29:26 Integrated Voltage Measurement... 13:30:10 Voltage Offset Correction: v_off_ini = 0.000000126 V, v_off_fin = 0.000000865 V 13:30:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142316022 Vs 13:30:10 Integrated Voltage Measurement... 13:30:41 Voltage Offset Correction: v_off_ini = 0.000000733 V, v_off_fin = -0.000001732 V 13:30:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142297493 Vs 13:30:42   Voltage Measurement, V = 0.000000 V 13:30:43 Temperature Measurement, Probe Number = 0, T = 20.836000 C 13:30:43 Temperature Measurement, Probe Number = 1, T = 22.470000 C 13:30:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.84 P2 = 3458_Meas_Junction, Value = 22.47 13:30:43 Integrated Voltage Measurement... 13:31:18 Voltage Offset Correction: v_off_ini = -0.000000363 V, v_off_fin = 0.000001179 V 13:31:18 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142326911 Vs 13:31:18 Integrated Voltage Measurement... 13:31:57 Voltage Offset Correction: v_off_ini = 0.000000516 V, v_off_fin = -0.000002300 V 13:31:57 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142287009 Vs 13:31:58   Voltage Measurement, V = 0.000000 V 13:31:59 Temperature Measurement, Probe Number = 0, T = 20.820000 C 13:32:00 Temperature Measurement, Probe Number = 1, T = 22.468000 C 13:32:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 22.47 13:32:00 Integrated Voltage Measurement... 13:32:49 Voltage Offset Correction: v_off_ini = -0.000000123 V, v_off_fin = 0.000000277 V 13:32:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142327066 Vs 13:32:49 Integrated Voltage Measurement... 13:33:21 Voltage Offset Correction: v_off_ini = 0.000000712 V, v_off_fin = -0.000002099 V 13:33:21 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142293180 Vs 13:33:22   Voltage Measurement, V = 0.000000 V 13:33:22 Temperature Measurement, Probe Number = 0, T = 20.800000 C 13:33:23 Temperature Measurement, Probe Number = 1, T = 22.489000 C 13:33:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 22.49 13:33:23 Integrated Voltage Measurement... 13:33:58 Voltage Offset Correction: v_off_ini = -0.000000201 V, v_off_fin = 0.000000437 V 13:33:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142321600 Vs 13:33:58 Integrated Voltage Measurement... 13:34:29 Voltage Offset Correction: v_off_ini = 0.000000576 V, v_off_fin = -0.000002881 V 13:34:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142285268 Vs 13:34:30   Voltage Measurement, V = 0.000000 V 13:34:30 Temperature Measurement, Probe Number = 0, T = 20.809000 C 13:34:31 Temperature Measurement, Probe Number = 1, T = 22.478000 C 13:34:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.81 P2 = 3458_Meas_Junction, Value = 22.48 13:34:31 Integrated Voltage Measurement... 13:35:03 Voltage Offset Correction: v_off_ini = -0.000000279 V, v_off_fin = 0.000002169 V 13:35:03 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142322176 Vs 13:35:03 Integrated Voltage Measurement... 13:35:36 Voltage Offset Correction: v_off_ini = 0.000000892 V, v_off_fin = -0.000000851 V 13:35:36 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142299756 Vs 13:35:37   Voltage Measurement, V = 0.000000 V 13:35:38 Temperature Measurement, Probe Number = 0, T = 20.820000 C 13:35:39 Temperature Measurement, Probe Number = 1, T = 22.484000 C 13:35:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 22.48 13:35:39 Integrated Voltage Measurement... 13:36:11 Voltage Offset Correction: v_off_ini = -0.000000159 V, v_off_fin = 0.000001628 V 13:36:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142323294 Vs 13:36:11 Integrated Voltage Measurement... 13:36:42 Voltage Offset Correction: v_off_ini = 0.000000882 V, v_off_fin = -0.000001793 V 13:36:42 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142292296 Vs