SLAC Magnetic Measurements Date: 09-23-2020 Time: 17:12:34 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31_Upstairs Serial Number: PC33408 Run Number: 2 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 2 17:12:37 Ambient Measurement Device(s) Being Used, type = None 17:12:37 Magnet Voltage Measurement Device(s) Being Used, type = None 17:12:38 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:12:38 XMAG Device(s) Being Used, type = None 17:12:38 Ambient Measurement Device(s) Being Used, type = None 17:12:41   Voltage Measurement, V = 0.000000 V 17:12:42 Temperature Measurement, Probe Number = 0, T = 22.737000 C 17:12:42 Temperature Measurement, Probe Number = 1, T = 23.401000 C 17:12:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.74 P2 = 3458_Meas_Junction, Value = 23.40 17:12:43 Integrated Voltage Measurement... 17:13:15 Voltage Offset Correction: v_off_ini = 0.000002036 V, v_off_fin = 0.000002785 V 17:13:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142416095 Vs 17:13:16 Integrated Voltage Measurement... 17:13:58 Voltage Offset Correction: v_off_ini = 0.000001981 V, v_off_fin = -0.000000579 V 17:13:58 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142354573 Vs 17:13:59   Voltage Measurement, V = 0.000000 V 17:13:59 Temperature Measurement, Probe Number = 0, T = 22.721000 C 17:14:00 Temperature Measurement, Probe Number = 1, T = 23.351000 C 17:14:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.72 P2 = 3458_Meas_Junction, Value = 23.35 17:14:00 Integrated Voltage Measurement... 17:14:40 Voltage Offset Correction: v_off_ini = 0.000001138 V, v_off_fin = 0.000002557 V 17:14:40 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142382295 Vs 17:14:40 Integrated Voltage Measurement... 17:15:19 Voltage Offset Correction: v_off_ini = 0.000001967 V, v_off_fin = -0.000001319 V 17:15:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142385011 Vs 17:15:20   Voltage Measurement, V = 0.000000 V 17:15:20 Temperature Measurement, Probe Number = 0, T = 22.726000 C 17:15:21 Temperature Measurement, Probe Number = 1, T = 23.333000 C 17:15:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.73 P2 = 3458_Meas_Junction, Value = 23.33 17:15:21 Integrated Voltage Measurement... 17:15:58 Voltage Offset Correction: v_off_ini = 0.000001042 V, v_off_fin = 0.000002446 V 17:15:58 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142420462 Vs 17:15:58 Integrated Voltage Measurement... 17:16:34 Voltage Offset Correction: v_off_ini = 0.000002034 V, v_off_fin = 0.000000499 V 17:16:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142365178 Vs 17:16:35   Voltage Measurement, V = 0.000000 V 17:16:36 Temperature Measurement, Probe Number = 0, T = 22.749000 C 17:16:37 Temperature Measurement, Probe Number = 1, T = 23.311000 C 17:16:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.31 17:16:37 Integrated Voltage Measurement... 17:17:17 Voltage Offset Correction: v_off_ini = 0.000001304 V, v_off_fin = 0.000003085 V 17:17:17 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142397084 Vs 17:17:17 Integrated Voltage Measurement... 17:18:02 Voltage Offset Correction: v_off_ini = 0.000002023 V, v_off_fin = -0.000000802 V 17:18:02 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142370047 Vs 17:18:03   Voltage Measurement, V = 0.000000 V 17:18:04 Temperature Measurement, Probe Number = 0, T = 22.765000 C 17:18:04 Temperature Measurement, Probe Number = 1, T = 23.298000 C 17:18:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.77 P2 = 3458_Meas_Junction, Value = 23.30 17:18:04 Integrated Voltage Measurement... 17:18:38 Voltage Offset Correction: v_off_ini = 0.000001148 V, v_off_fin = 0.000003705 V 17:18:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142399661 Vs 17:18:38 Integrated Voltage Measurement... 17:19:16 Voltage Offset Correction: v_off_ini = 0.000002165 V, v_off_fin = -0.000001080 V 17:19:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142393526 Vs 17:19:17   Voltage Measurement, V = 0.000000 V 17:19:18 Temperature Measurement, Probe Number = 0, T = 22.753000 C 17:19:18 Temperature Measurement, Probe Number = 1, T = 23.307000 C 17:19:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.31 17:19:18 Integrated Voltage Measurement... 17:19:51 Voltage Offset Correction: v_off_ini = 0.000000737 V, v_off_fin = 0.000002709 V 17:19:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142425909 Vs 17:19:51 Integrated Voltage Measurement... 17:20:24 Voltage Offset Correction: v_off_ini = 0.000002318 V, v_off_fin = -0.000001827 V 17:20:24 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142383660 Vs 17:20:25   Voltage Measurement, V = 0.000000 V 17:20:25 Temperature Measurement, Probe Number = 0, T = 22.751000 C 17:20:26 Temperature Measurement, Probe Number = 1, T = 23.300000 C 17:20:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.30 17:20:26 Integrated Voltage Measurement... 17:20:58 Voltage Offset Correction: v_off_ini = 0.000000920 V, v_off_fin = 0.000003016 V 17:20:58 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142418533 Vs 17:20:58 Integrated Voltage Measurement... 17:21:34 Voltage Offset Correction: v_off_ini = 0.000002052 V, v_off_fin = -0.000000726 V 17:21:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142369525 Vs 17:21:35   Voltage Measurement, V = 0.000000 V 17:21:36 Temperature Measurement, Probe Number = 0, T = 22.738000 C 17:21:36 Temperature Measurement, Probe Number = 1, T = 23.292000 C 17:21:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.74 P2 = 3458_Meas_Junction, Value = 23.29 17:21:36 Integrated Voltage Measurement... 17:22:08 Voltage Offset Correction: v_off_ini = 0.000000805 V, v_off_fin = 0.000003116 V 17:22:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142406335 Vs 17:22:08 Integrated Voltage Measurement... 17:22:42 Voltage Offset Correction: v_off_ini = 0.000002486 V, v_off_fin = -0.000000317 V 17:22:42 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142395153 Vs 17:22:43   Voltage Measurement, V = 0.000000 V 17:22:43 Temperature Measurement, Probe Number = 0, T = 22.725000 C 17:22:44 Temperature Measurement, Probe Number = 1, T = 23.286000 C 17:22:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.73 P2 = 3458_Meas_Junction, Value = 23.29 17:22:44 Integrated Voltage Measurement... 17:23:17 Voltage Offset Correction: v_off_ini = 0.000000734 V, v_off_fin = 0.000002979 V 17:23:17 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142417343 Vs 17:23:17 Integrated Voltage Measurement... 17:23:53 Voltage Offset Correction: v_off_ini = 0.000002367 V, v_off_fin = -0.000000917 V 17:23:53 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142379203 Vs 17:23:54   Voltage Measurement, V = 0.000000 V 17:23:54 Temperature Measurement, Probe Number = 0, T = 22.724000 C 17:23:55 Temperature Measurement, Probe Number = 1, T = 23.269000 C 17:23:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.72 P2 = 3458_Meas_Junction, Value = 23.27 17:23:55 Integrated Voltage Measurement... 17:24:29 Voltage Offset Correction: v_off_ini = 0.000001102 V, v_off_fin = 0.000002405 V 17:24:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142412327 Vs 17:24:29 Integrated Voltage Measurement... 17:25:02 Voltage Offset Correction: v_off_ini = 0.000002235 V, v_off_fin = 0.000000126 V 17:25:02 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142372910 Vs