SLAC Magnetic Measurements Date: 09-08-2020 Time: 14:08:29 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: HP_PC33408 Run Number: 8 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 8 14:08:32 Ambient Measurement Device(s) Being Used, type = None 14:08:32 Magnet Voltage Measurement Device(s) Being Used, type = None 14:08:32 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:08:32 XMAG Device(s) Being Used, type = None 14:08:32 Ambient Measurement Device(s) Being Used, type = None 14:09:24   Voltage Measurement, V = 0.000000 V 14:09:24 Temperature Measurement, Probe Number = 0, T = 21.640000 C 14:09:25 Temperature Measurement, Probe Number = 1, T = 22.480000 C 14:09:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.64 P2 = 3458_Meas_Junction, Value = 22.48 14:09:25 Integrated Voltage Measurement... 14:10:07 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = 0.000000361 V 14:10:07 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142338796 Vs 14:10:07 Integrated Voltage Measurement... 14:10:45 Voltage Offset Correction: v_off_ini = 0.000000404 V, v_off_fin = -0.000002013 V 14:10:45 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142319560 Vs 14:10:46   Voltage Measurement, V = 0.000000 V 14:10:47 Temperature Measurement, Probe Number = 0, T = 21.623000 C 14:10:47 Temperature Measurement, Probe Number = 1, T = 22.489000 C 14:10:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 22.49 14:10:47 Integrated Voltage Measurement... 14:11:18 Voltage Offset Correction: v_off_ini = -0.000000899 V, v_off_fin = 0.000000342 V 14:11:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142340586 Vs 14:11:18 Integrated Voltage Measurement... 14:11:49 Voltage Offset Correction: v_off_ini = 0.000000540 V, v_off_fin = -0.000001268 V 14:11:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142305264 Vs 14:11:50   Voltage Measurement, V = 0.000000 V 14:11:51 Temperature Measurement, Probe Number = 0, T = 21.611000 C 14:11:52 Temperature Measurement, Probe Number = 1, T = 22.504000 C 14:11:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 22.50 14:11:52 Integrated Voltage Measurement... 14:12:24 Voltage Offset Correction: v_off_ini = -0.000000991 V, v_off_fin = -0.000000702 V 14:12:24 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142330071 Vs 14:12:24 Integrated Voltage Measurement... 14:12:56 Voltage Offset Correction: v_off_ini = 0.000000218 V, v_off_fin = -0.000001931 V 14:12:56 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142326730 Vs 14:12:57   Voltage Measurement, V = 0.000000 V 14:12:58 Temperature Measurement, Probe Number = 0, T = 21.621000 C 14:12:58 Temperature Measurement, Probe Number = 1, T = 22.498000 C 14:12:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 22.50 14:12:58 Integrated Voltage Measurement... 14:13:33 Voltage Offset Correction: v_off_ini = -0.000000753 V, v_off_fin = 0.000000571 V 14:13:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142360185 Vs 14:13:33 Integrated Voltage Measurement... 14:14:05 Voltage Offset Correction: v_off_ini = 0.000000193 V, v_off_fin = -0.000002625 V 14:14:05 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142319353 Vs 14:14:06   Voltage Measurement, V = 0.000000 V 14:14:06 Temperature Measurement, Probe Number = 0, T = 21.628000 C 14:14:07 Temperature Measurement, Probe Number = 1, T = 22.503000 C 14:14:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.63 P2 = 3458_Meas_Junction, Value = 22.50 14:14:07 Integrated Voltage Measurement... 14:14:44 Voltage Offset Correction: v_off_ini = -0.000000755 V, v_off_fin = 0.000001342 V 14:14:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142358945 Vs 14:14:44 Integrated Voltage Measurement... 14:15:16 Voltage Offset Correction: v_off_ini = 0.000000587 V, v_off_fin = -0.000001892 V 14:15:16 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142321413 Vs 14:15:17   Voltage Measurement, V = 0.000000 V 14:15:18 Temperature Measurement, Probe Number = 0, T = 21.622000 C 14:15:18 Temperature Measurement, Probe Number = 1, T = 22.507000 C 14:15:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 22.51 14:15:18 Integrated Voltage Measurement... 14:15:50 Voltage Offset Correction: v_off_ini = -0.000000680 V, v_off_fin = 0.000001525 V 14:15:50 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142349002 Vs 14:15:50 Integrated Voltage Measurement... 14:16:23 Voltage Offset Correction: v_off_ini = 0.000000340 V, v_off_fin = -0.000002994 V 14:16:23 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142317632 Vs 14:16:24   Voltage Measurement, V = 0.000000 V 14:16:25 Temperature Measurement, Probe Number = 0, T = 21.614000 C 14:16:25 Temperature Measurement, Probe Number = 1, T = 22.510000 C 14:16:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 22.51 14:16:25 Integrated Voltage Measurement... 14:16:59 Voltage Offset Correction: v_off_ini = -0.000000619 V, v_off_fin = 0.000000700 V 14:16:59 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142356140 Vs 14:16:59 Integrated Voltage Measurement... 14:17:31 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = -0.000002546 V 14:17:31 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142318193 Vs 14:17:32   Voltage Measurement, V = 0.000000 V 14:17:33 Temperature Measurement, Probe Number = 0, T = 21.608000 C 14:17:33 Temperature Measurement, Probe Number = 1, T = 22.508000 C 14:17:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 22.51 14:17:33 Integrated Voltage Measurement... 14:18:06 Voltage Offset Correction: v_off_ini = -0.000001101 V, v_off_fin = 0.000000701 V 14:18:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142353624 Vs 14:18:06 Integrated Voltage Measurement... 14:18:39 Voltage Offset Correction: v_off_ini = 0.000000214 V, v_off_fin = -0.000002462 V 14:18:39 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142317480 Vs 14:18:40   Voltage Measurement, V = 0.000000 V 14:18:41 Temperature Measurement, Probe Number = 0, T = 21.597000 C 14:18:41 Temperature Measurement, Probe Number = 1, T = 22.505000 C 14:18:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.60 P2 = 3458_Meas_Junction, Value = 22.50 14:18:41 Integrated Voltage Measurement... 14:19:20 Voltage Offset Correction: v_off_ini = -0.000000686 V, v_off_fin = 0.000000974 V 14:19:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142356106 Vs 14:19:20 Integrated Voltage Measurement... 14:19:57 Voltage Offset Correction: v_off_ini = 0.000000248 V, v_off_fin = -0.000002714 V 14:19:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142311167 Vs 14:19:58   Voltage Measurement, V = 0.000000 V 14:19:58 Temperature Measurement, Probe Number = 0, T = 21.589000 C 14:19:59 Temperature Measurement, Probe Number = 1, T = 22.513000 C 14:19:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.59 P2 = 3458_Meas_Junction, Value = 22.51 14:19:59 Integrated Voltage Measurement... 14:20:31 Voltage Offset Correction: v_off_ini = -0.000000999 V, v_off_fin = 0.000001264 V 14:20:31 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142355695 Vs 14:20:31 Integrated Voltage Measurement... 14:21:06 Voltage Offset Correction: v_off_ini = 0.000000385 V, v_off_fin = -0.000002188 V 14:21:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142313523 Vs