SLAC Magnetic Measurements Date: 12-02-2020 Time: 13:38:47 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 13:39:05 Ambient Measurement Device(s) Being Used, type = None 13:39:05 Magnet Voltage Measurement Device(s) Being Used, type = None 13:39:06 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:39:06 XMAG Device(s) Being Used, type = None 13:39:06 Ambient Measurement Device(s) Being Used, type = None 13:39:13   Voltage Measurement, V = 0.000000 V 13:39:14 Temperature Measurement, Probe Number = 0, T = 20.865000 C 13:39:15 Temperature Measurement, Probe Number = 1, T = 22.448000 C 13:39:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.86 P2 = 3458_Meas_Junction, Value = 22.45 13:39:15 Integrated Voltage Measurement... 13:39:42 Voltage Offset Correction: v_off_ini = 0.000001016 V, v_off_fin = 0.000000860 V 13:39:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142294140 Vs 13:39:42 Integrated Voltage Measurement... 13:40:14 Voltage Offset Correction: v_off_ini = 0.000001041 V, v_off_fin = -0.000003255 V 13:40:14 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142305888 Vs 13:40:15   Voltage Measurement, V = 0.000000 V 13:40:16 Temperature Measurement, Probe Number = 0, T = 20.844000 C 13:40:16 Temperature Measurement, Probe Number = 1, T = 22.400000 C 13:40:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.84 P2 = 3458_Meas_Junction, Value = 22.40 13:40:16 Integrated Voltage Measurement... 13:40:50 Voltage Offset Correction: v_off_ini = -0.000000474 V, v_off_fin = 0.000000822 V 13:40:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142357360 Vs 13:40:50 Integrated Voltage Measurement... 13:41:32 Voltage Offset Correction: v_off_ini = 0.000000709 V, v_off_fin = -0.000001803 V 13:41:32 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142318923 Vs 13:41:33   Voltage Measurement, V = 0.000000 V 13:41:33 Temperature Measurement, Probe Number = 0, T = 20.843000 C 13:41:34 Temperature Measurement, Probe Number = 1, T = 22.386000 C 13:41:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.84 P2 = 3458_Meas_Junction, Value = 22.39 13:41:34 Integrated Voltage Measurement... 13:42:14 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = 0.000000837 V 13:42:14 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142373697 Vs 13:42:14 Integrated Voltage Measurement... 13:42:45 Voltage Offset Correction: v_off_ini = 0.000000697 V, v_off_fin = -0.000002663 V 13:42:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142313607 Vs 13:42:46   Voltage Measurement, V = 0.000000 V 13:42:47 Temperature Measurement, Probe Number = 0, T = 20.838000 C 13:42:47 Temperature Measurement, Probe Number = 1, T = 22.447000 C 13:42:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.84 P2 = 3458_Meas_Junction, Value = 22.45 13:42:47 Integrated Voltage Measurement... 13:43:19 Voltage Offset Correction: v_off_ini = -0.000000861 V, v_off_fin = 0.000001649 V 13:43:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142363941 Vs 13:43:19 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000002936 V 13:43:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142323841 Vs 13:43:54   Voltage Measurement, V = 0.000000 V 13:43:54 Temperature Measurement, Probe Number = 0, T = 20.826000 C 13:43:55 Temperature Measurement, Probe Number = 1, T = 22.471000 C 13:43:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.83 P2 = 3458_Meas_Junction, Value = 22.47 13:43:55 Integrated Voltage Measurement... 13:44:41 Voltage Offset Correction: v_off_ini = -0.000000321 V, v_off_fin = 0.000001798 V 13:44:41 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142389314 Vs 13:44:41 Integrated Voltage Measurement... 13:45:13 Voltage Offset Correction: v_off_ini = 0.000000780 V, v_off_fin = -0.000003113 V 13:45:13 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142312985 Vs 13:45:14   Voltage Measurement, V = 0.000000 V 13:45:15 Temperature Measurement, Probe Number = 0, T = 20.811000 C 13:45:16 Temperature Measurement, Probe Number = 1, T = 22.491000 C 13:45:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.81 P2 = 3458_Meas_Junction, Value = 22.49 13:45:16 Integrated Voltage Measurement... 13:45:47 Voltage Offset Correction: v_off_ini = -0.000000923 V, v_off_fin = 0.000001337 V 13:45:47 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142374699 Vs 13:45:47 Integrated Voltage Measurement... 13:46:18 Voltage Offset Correction: v_off_ini = 0.000000984 V, v_off_fin = -0.000002586 V 13:46:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142311420 Vs 13:46:20   Voltage Measurement, V = 0.000000 V 13:46:20 Temperature Measurement, Probe Number = 0, T = 20.810000 C 13:46:21 Temperature Measurement, Probe Number = 1, T = 22.493000 C 13:46:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.81 P2 = 3458_Meas_Junction, Value = 22.49 13:46:21 Integrated Voltage Measurement... 13:46:52 Voltage Offset Correction: v_off_ini = -0.000001062 V, v_off_fin = 0.000000770 V 13:46:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142363263 Vs 13:46:52 Integrated Voltage Measurement... 13:47:23 Voltage Offset Correction: v_off_ini = 0.000000881 V, v_off_fin = -0.000003021 V 13:47:23 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142319510 Vs 13:47:24   Voltage Measurement, V = 0.000000 V 13:47:25 Temperature Measurement, Probe Number = 0, T = 20.804000 C 13:47:25 Temperature Measurement, Probe Number = 1, T = 22.511000 C 13:47:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 22.51 13:47:25 Integrated Voltage Measurement... 13:47:57 Voltage Offset Correction: v_off_ini = -0.000000980 V, v_off_fin = 0.000001077 V 13:47:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142373197 Vs 13:47:57 Integrated Voltage Measurement... 13:48:29 Voltage Offset Correction: v_off_ini = 0.000000580 V, v_off_fin = -0.000002595 V 13:48:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142319698 Vs 13:48:30   Voltage Measurement, V = 0.000000 V 13:48:31 Temperature Measurement, Probe Number = 0, T = 20.799000 C 13:48:32 Temperature Measurement, Probe Number = 1, T = 22.516000 C 13:48:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 22.52 13:48:32 Integrated Voltage Measurement... 13:49:03 Voltage Offset Correction: v_off_ini = -0.000000914 V, v_off_fin = 0.000000943 V 13:49:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142367472 Vs 13:49:03 Integrated Voltage Measurement... 13:49:35 Voltage Offset Correction: v_off_ini = 0.000000834 V, v_off_fin = -0.000001180 V 13:49:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142312328 Vs 13:49:36   Voltage Measurement, V = 0.000000 V 13:49:36 Temperature Measurement, Probe Number = 0, T = 20.794000 C 13:49:37 Temperature Measurement, Probe Number = 1, T = 22.500000 C 13:49:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 22.50 13:49:37 Integrated Voltage Measurement... 13:50:07 Voltage Offset Correction: v_off_ini = -0.000001022 V, v_off_fin = 0.000000407 V 13:50:07 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142361652 Vs 13:50:07 Integrated Voltage Measurement... 13:50:38 Voltage Offset Correction: v_off_ini = 0.000000990 V, v_off_fin = -0.000002256 V 13:50:38 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142323723 Vs