SLAC Magnetic Measurements Date: 11-18-2020 Time: 13:12:57 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 13:13:15 Ambient Measurement Device(s) Being Used, type = None 13:13:15 Magnet Voltage Measurement Device(s) Being Used, type = None 13:13:15 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:13:15 XMAG Device(s) Being Used, type = None 13:13:15 Ambient Measurement Device(s) Being Used, type = None 13:13:18   Voltage Measurement, V = 0.000000 V 13:13:19 Temperature Measurement, Probe Number = 0, T = 20.915000 C 13:13:19 Temperature Measurement, Probe Number = 1, T = 21.353000 C 13:13:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.35 13:13:20 Integrated Voltage Measurement... 13:13:50 Voltage Offset Correction: v_off_ini = -0.000001113 V, v_off_fin = 0.000000437 V 13:13:50 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142422259 Vs 13:13:50 Integrated Voltage Measurement... 13:14:21 Voltage Offset Correction: v_off_ini = -0.000000804 V, v_off_fin = -0.000003765 V 13:14:21 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142350828 Vs 13:14:22   Voltage Measurement, V = 0.000000 V 13:14:23 Temperature Measurement, Probe Number = 0, T = 20.904000 C 13:14:23 Temperature Measurement, Probe Number = 1, T = 21.364000 C 13:14:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.36 13:14:23 Integrated Voltage Measurement... 13:15:02 Voltage Offset Correction: v_off_ini = -0.000001709 V, v_off_fin = -0.000000448 V 13:15:02 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142390371 Vs 13:15:02 Integrated Voltage Measurement... 13:15:42 Voltage Offset Correction: v_off_ini = -0.000000865 V, v_off_fin = -0.000001918 V 13:15:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142370041 Vs 13:15:43   Voltage Measurement, V = 0.000000 V 13:15:44 Temperature Measurement, Probe Number = 0, T = 20.936000 C 13:15:45 Temperature Measurement, Probe Number = 1, T = 21.372000 C 13:15:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.37 13:15:45 Integrated Voltage Measurement... 13:16:20 Voltage Offset Correction: v_off_ini = -0.000001252 V, v_off_fin = -0.000000209 V 13:16:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142363071 Vs 13:16:20 Integrated Voltage Measurement... 13:16:56 Voltage Offset Correction: v_off_ini = -0.000000717 V, v_off_fin = -0.000004505 V 13:16:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142374342 Vs 13:16:57   Voltage Measurement, V = 0.000000 V 13:16:57 Temperature Measurement, Probe Number = 0, T = 20.940000 C 13:16:58 Temperature Measurement, Probe Number = 1, T = 21.362000 C 13:16:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.36 13:16:58 Integrated Voltage Measurement... 13:17:29 Voltage Offset Correction: v_off_ini = -0.000002503 V, v_off_fin = -0.000000995 V 13:17:29 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142412922 Vs 13:17:29 Integrated Voltage Measurement... 13:18:01 Voltage Offset Correction: v_off_ini = -0.000000700 V, v_off_fin = -0.000004644 V 13:18:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142367266 Vs 13:18:02   Voltage Measurement, V = 0.000000 V 13:18:03 Temperature Measurement, Probe Number = 0, T = 20.907000 C 13:18:04 Temperature Measurement, Probe Number = 1, T = 21.359000 C 13:18:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.36 13:18:04 Integrated Voltage Measurement... 13:18:35 Voltage Offset Correction: v_off_ini = -0.000002361 V, v_off_fin = -0.000000555 V 13:18:35 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142425748 Vs 13:18:35 Integrated Voltage Measurement... 13:19:13 Voltage Offset Correction: v_off_ini = -0.000000826 V, v_off_fin = -0.000004584 V 13:19:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142371058 Vs 13:19:14   Voltage Measurement, V = 0.000000 V 13:19:15 Temperature Measurement, Probe Number = 0, T = 20.878000 C 13:19:16 Temperature Measurement, Probe Number = 1, T = 21.385000 C 13:19:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.88 P2 = 3458_Meas_Junction, Value = 21.39 13:19:16 Integrated Voltage Measurement... 13:19:46 Voltage Offset Correction: v_off_ini = -0.000002514 V, v_off_fin = -0.000000449 V 13:19:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142417172 Vs 13:19:46 Integrated Voltage Measurement... 13:20:16 Voltage Offset Correction: v_off_ini = -0.000000635 V, v_off_fin = -0.000003867 V 13:20:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142368806 Vs 13:20:17   Voltage Measurement, V = 0.000000 V 13:20:18 Temperature Measurement, Probe Number = 0, T = 20.867000 C 13:20:19 Temperature Measurement, Probe Number = 1, T = 21.398000 C 13:20:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.87 P2 = 3458_Meas_Junction, Value = 21.40 13:20:19 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = -0.000002391 V, v_off_fin = -0.000000166 V 13:20:50 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142426598 Vs 13:20:50 Integrated Voltage Measurement... 13:21:21 Voltage Offset Correction: v_off_ini = -0.000000630 V, v_off_fin = -0.000004325 V 13:21:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142376523 Vs 13:21:22   Voltage Measurement, V = 0.000000 V 13:21:22 Temperature Measurement, Probe Number = 0, T = 20.865000 C 13:21:23 Temperature Measurement, Probe Number = 1, T = 21.414000 C 13:21:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.86 P2 = 3458_Meas_Junction, Value = 21.41 13:21:23 Integrated Voltage Measurement... 13:21:56 Voltage Offset Correction: v_off_ini = -0.000002156 V, v_off_fin = -0.000000390 V 13:21:56 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142435900 Vs 13:21:56 Integrated Voltage Measurement... 13:22:26 Voltage Offset Correction: v_off_ini = -0.000000740 V, v_off_fin = -0.000004086 V 13:22:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142359820 Vs 13:22:27   Voltage Measurement, V = 0.000000 V 13:22:28 Temperature Measurement, Probe Number = 0, T = 20.864000 C 13:22:28 Temperature Measurement, Probe Number = 1, T = 21.425000 C 13:22:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.86 P2 = 3458_Meas_Junction, Value = 21.43 13:22:28 Integrated Voltage Measurement... 13:23:02 Voltage Offset Correction: v_off_ini = -0.000002428 V, v_off_fin = -0.000000494 V 13:23:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142414613 Vs 13:23:02 Integrated Voltage Measurement... 13:23:34 Voltage Offset Correction: v_off_ini = -0.000000784 V, v_off_fin = -0.000003621 V 13:23:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142372078 Vs 13:23:35   Voltage Measurement, V = 0.000000 V 13:23:35 Temperature Measurement, Probe Number = 0, T = 20.855000 C 13:23:36 Temperature Measurement, Probe Number = 1, T = 21.424000 C 13:23:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.86 P2 = 3458_Meas_Junction, Value = 21.42 13:23:36 Integrated Voltage Measurement... 13:24:07 Voltage Offset Correction: v_off_ini = -0.000002285 V, v_off_fin = 0.000000387 V 13:24:07 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142433846 Vs 13:24:07 Integrated Voltage Measurement... 13:24:37 Voltage Offset Correction: v_off_ini = -0.000000860 V, v_off_fin = -0.000004797 V 13:24:37 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142379910 Vs