SLAC Magnetic Measurements Date: 10-21-2020 Time: 11:36:25 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 11:36:43 Ambient Measurement Device(s) Being Used, type = None 11:36:43 Magnet Voltage Measurement Device(s) Being Used, type = None 11:36:43 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:36:43 XMAG Device(s) Being Used, type = None 11:36:43 Ambient Measurement Device(s) Being Used, type = None 11:36:46   Voltage Measurement, V = 0.000000 V 11:36:46 Temperature Measurement, Probe Number = 0, T = 20.911000 C 11:36:47 Temperature Measurement, Probe Number = 1, T = 20.577000 C 11:36:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 20.58 11:36:47 Integrated Voltage Measurement... 11:37:17 Voltage Offset Correction: v_off_ini = -0.000000442 V, v_off_fin = 0.000000691 V 11:37:17 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142385960 Vs 11:37:17 Integrated Voltage Measurement... 11:37:51 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = -0.000003759 V 11:37:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142355502 Vs 11:37:52   Voltage Measurement, V = 0.000000 V 11:37:52 Temperature Measurement, Probe Number = 0, T = 20.925000 C 11:37:53 Temperature Measurement, Probe Number = 1, T = 20.455000 C 11:37:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 20.45 11:37:53 Integrated Voltage Measurement... 11:38:25 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = 0.000000053 V 11:38:25 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142386997 Vs 11:38:25 Integrated Voltage Measurement... 11:38:57 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000003827 V 11:38:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142353733 Vs 11:38:58   Voltage Measurement, V = 0.000000 V 11:38:58 Temperature Measurement, Probe Number = 0, T = 20.918000 C 11:38:59 Temperature Measurement, Probe Number = 1, T = 20.364000 C 11:38:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 20.36 11:38:59 Integrated Voltage Measurement... 11:39:33 Voltage Offset Correction: v_off_ini = -0.000001515 V, v_off_fin = 0.000000174 V 11:39:33 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142390727 Vs 11:39:33 Integrated Voltage Measurement... 11:40:06 Voltage Offset Correction: v_off_ini = 0.000000062 V, v_off_fin = -0.000003244 V 11:40:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142343463 Vs 11:40:07   Voltage Measurement, V = 0.000000 V 11:40:08 Temperature Measurement, Probe Number = 0, T = 20.912000 C 11:40:09 Temperature Measurement, Probe Number = 1, T = 20.397000 C 11:40:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 20.40 11:40:09 Integrated Voltage Measurement... 11:40:42 Voltage Offset Correction: v_off_ini = -0.000001582 V, v_off_fin = -0.000001142 V 11:40:42 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142381219 Vs 11:40:42 Integrated Voltage Measurement... 11:41:15 Voltage Offset Correction: v_off_ini = -0.000000068 V, v_off_fin = -0.000003673 V 11:41:15 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142347349 Vs 11:41:16   Voltage Measurement, V = 0.000000 V 11:41:16 Temperature Measurement, Probe Number = 0, T = 20.893000 C 11:41:17 Temperature Measurement, Probe Number = 1, T = 20.435000 C 11:41:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 20.43 11:41:17 Integrated Voltage Measurement... 11:41:49 Voltage Offset Correction: v_off_ini = -0.000001657 V, v_off_fin = 0.000000441 V 11:41:49 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142389574 Vs 11:41:49 Integrated Voltage Measurement... 11:42:22 Voltage Offset Correction: v_off_ini = 0.000000121 V, v_off_fin = -0.000002985 V 11:42:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142341585 Vs 11:42:23   Voltage Measurement, V = 0.000000 V 11:42:24 Temperature Measurement, Probe Number = 0, T = 20.894000 C 11:42:24 Temperature Measurement, Probe Number = 1, T = 20.387000 C 11:42:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 20.39 11:42:24 Integrated Voltage Measurement... 11:42:56 Voltage Offset Correction: v_off_ini = -0.000001776 V, v_off_fin = 0.000000626 V 11:42:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142393858 Vs 11:42:56 Integrated Voltage Measurement... 11:43:28 Voltage Offset Correction: v_off_ini = -0.000000196 V, v_off_fin = -0.000004313 V 11:43:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142338099 Vs 11:43:29   Voltage Measurement, V = 0.000000 V 11:43:29 Temperature Measurement, Probe Number = 0, T = 20.898000 C 11:43:30 Temperature Measurement, Probe Number = 1, T = 20.336000 C 11:43:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 20.34 11:43:30 Integrated Voltage Measurement... 11:44:03 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = 0.000000674 V 11:44:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142388569 Vs 11:44:03 Integrated Voltage Measurement... 11:44:35 Voltage Offset Correction: v_off_ini = 0.000000099 V, v_off_fin = -0.000004411 V 11:44:35 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142350494 Vs 11:44:36   Voltage Measurement, V = 0.000000 V 11:44:36 Temperature Measurement, Probe Number = 0, T = 20.894000 C 11:44:37 Temperature Measurement, Probe Number = 1, T = 20.335000 C 11:44:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 20.34 11:44:37 Integrated Voltage Measurement... 11:45:09 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = -0.000000261 V 11:45:09 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142396510 Vs 11:45:09 Integrated Voltage Measurement... 11:45:43 Voltage Offset Correction: v_off_ini = -0.000000226 V, v_off_fin = -0.000003997 V 11:45:43 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142346845 Vs 11:45:44   Voltage Measurement, V = 0.000000 V 11:45:44 Temperature Measurement, Probe Number = 0, T = 20.896000 C 11:45:45 Temperature Measurement, Probe Number = 1, T = 20.413000 C 11:45:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 20.41 11:45:45 Integrated Voltage Measurement... 11:46:18 Voltage Offset Correction: v_off_ini = -0.000001574 V, v_off_fin = 0.000000614 V 11:46:18 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142391467 Vs 11:46:18 Integrated Voltage Measurement... 11:46:50 Voltage Offset Correction: v_off_ini = -0.000000092 V, v_off_fin = -0.000003544 V 11:46:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142338987 Vs 11:46:51   Voltage Measurement, V = 0.000000 V 11:46:52 Temperature Measurement, Probe Number = 0, T = 20.889000 C 11:46:52 Temperature Measurement, Probe Number = 1, T = 20.471000 C 11:46:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 20.47 11:46:52 Integrated Voltage Measurement... 11:47:23 Voltage Offset Correction: v_off_ini = -0.000001894 V, v_off_fin = 0.000000413 V 11:47:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142384189 Vs 11:47:23 Integrated Voltage Measurement... 11:47:59 Voltage Offset Correction: v_off_ini = -0.000000154 V, v_off_fin = -0.000003043 V 11:47:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142333114 Vs