SLAC Magnetic Measurements Date: 10-06-2020 Time: 13:50:45 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 13:50:47 Ambient Measurement Device(s) Being Used, type = None 13:50:47 Magnet Voltage Measurement Device(s) Being Used, type = None 13:50:48 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:50:48 XMAG Device(s) Being Used, type = None 13:50:48 Ambient Measurement Device(s) Being Used, type = None 13:50:56   Voltage Measurement, V = 0.000000 V 13:50:57 Temperature Measurement, Probe Number = 0, T = 20.849000 C 13:50:57 Temperature Measurement, Probe Number = 1, T = 21.488000 C 13:50:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.85 P2 = 3458_Meas_Junction, Value = 21.49 13:50:57 Integrated Voltage Measurement... 13:51:24 Voltage Offset Correction: v_off_ini = -0.000000528 V, v_off_fin = -0.000000039 V 13:51:24 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142396857 Vs 13:51:24 Integrated Voltage Measurement... 13:51:56 Voltage Offset Correction: v_off_ini = 0.000000011 V, v_off_fin = -0.000003702 V 13:51:56 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142369634 Vs 13:51:57   Voltage Measurement, V = 0.000000 V 13:51:57 Temperature Measurement, Probe Number = 0, T = 20.821000 C 13:51:58 Temperature Measurement, Probe Number = 1, T = 21.478000 C 13:51:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 21.48 13:51:58 Integrated Voltage Measurement... 13:52:31 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = 0.000001311 V 13:52:31 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142400613 Vs 13:52:31 Integrated Voltage Measurement... 13:53:04 Voltage Offset Correction: v_off_ini = -0.000000054 V, v_off_fin = -0.000003197 V 13:53:04 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142352780 Vs 13:53:05   Voltage Measurement, V = 0.000000 V 13:53:06 Temperature Measurement, Probe Number = 0, T = 20.802000 C 13:53:06 Temperature Measurement, Probe Number = 1, T = 21.477000 C 13:53:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.48 13:53:06 Integrated Voltage Measurement... 13:53:39 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000000160 V 13:53:39 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142401949 Vs 13:53:39 Integrated Voltage Measurement... 13:54:17 Voltage Offset Correction: v_off_ini = -0.000000248 V, v_off_fin = -0.000003666 V 13:54:17 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142358983 Vs 13:54:18   Voltage Measurement, V = 0.000000 V 13:54:19 Temperature Measurement, Probe Number = 0, T = 20.787000 C 13:54:20 Temperature Measurement, Probe Number = 1, T = 21.457000 C 13:54:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.46 13:54:20 Integrated Voltage Measurement... 13:54:53 Voltage Offset Correction: v_off_ini = -0.000001506 V, v_off_fin = 0.000000145 V 13:54:53 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142410755 Vs 13:54:53 Integrated Voltage Measurement... 13:55:35 Voltage Offset Correction: v_off_ini = -0.000000322 V, v_off_fin = -0.000003867 V 13:55:35 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142362408 Vs 13:55:36   Voltage Measurement, V = 0.000000 V 13:55:37 Temperature Measurement, Probe Number = 0, T = 20.803000 C 13:55:37 Temperature Measurement, Probe Number = 1, T = 21.444000 C 13:55:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.44 13:55:37 Integrated Voltage Measurement... 13:56:09 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = 0.000000417 V 13:56:09 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142405847 Vs 13:56:09 Integrated Voltage Measurement... 13:56:41 Voltage Offset Correction: v_off_ini = -0.000000308 V, v_off_fin = -0.000003715 V 13:56:41 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142362038 Vs 13:56:42   Voltage Measurement, V = 0.000000 V 13:56:43 Temperature Measurement, Probe Number = 0, T = 20.796000 C 13:56:43 Temperature Measurement, Probe Number = 1, T = 21.427000 C 13:56:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.43 13:56:43 Integrated Voltage Measurement... 13:57:21 Voltage Offset Correction: v_off_ini = -0.000000719 V, v_off_fin = 0.000000745 V 13:57:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142347557 Vs 13:57:21 Integrated Voltage Measurement... 13:58:14 Voltage Offset Correction: v_off_ini = -0.000000336 V, v_off_fin = -0.000003617 V 13:58:14 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142357299 Vs 13:58:15   Voltage Measurement, V = 0.000000 V 13:58:16 Temperature Measurement, Probe Number = 0, T = 20.790000 C 13:58:16 Temperature Measurement, Probe Number = 1, T = 21.401000 C 13:58:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.40 13:58:16 Integrated Voltage Measurement... 13:58:51 Voltage Offset Correction: v_off_ini = -0.000001543 V, v_off_fin = -0.000000157 V 13:58:51 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142409586 Vs 13:58:51 Integrated Voltage Measurement... 13:59:25 Voltage Offset Correction: v_off_ini = -0.000000238 V, v_off_fin = -0.000003386 V 13:59:25 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142354775 Vs 13:59:26   Voltage Measurement, V = 0.000000 V 13:59:27 Temperature Measurement, Probe Number = 0, T = 20.789000 C 13:59:27 Temperature Measurement, Probe Number = 1, T = 21.393000 C 13:59:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.39 13:59:27 Integrated Voltage Measurement... 14:00:00 Voltage Offset Correction: v_off_ini = -0.000001620 V, v_off_fin = -0.000000082 V 14:00:00 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142408163 Vs 14:00:00 Integrated Voltage Measurement... 14:01:41 Voltage Offset Correction: v_off_ini = -0.000000395 V, v_off_fin = -0.000004609 V 14:01:41 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142355188 Vs 14:01:42   Voltage Measurement, V = 0.000000 V 14:01:43 Temperature Measurement, Probe Number = 0, T = 20.787000 C 14:01:43 Temperature Measurement, Probe Number = 1, T = 21.392000 C 14:01:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.39 14:01:43 Integrated Voltage Measurement... 14:02:15 Voltage Offset Correction: v_off_ini = -0.000001781 V, v_off_fin = -0.000000211 V 14:02:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142405515 Vs 14:02:15 Integrated Voltage Measurement... 14:02:48 Voltage Offset Correction: v_off_ini = -0.000000276 V, v_off_fin = -0.000002827 V 14:02:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142356050 Vs 14:02:49   Voltage Measurement, V = 0.000000 V 14:02:49 Temperature Measurement, Probe Number = 0, T = 20.792000 C 14:02:50 Temperature Measurement, Probe Number = 1, T = 21.412000 C 14:02:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.41 14:02:50 Integrated Voltage Measurement... 14:03:23 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = 0.000000511 V 14:03:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142406701 Vs 14:03:23 Integrated Voltage Measurement... 14:03:59 Voltage Offset Correction: v_off_ini = -0.000000217 V, v_off_fin = -0.000003756 V 14:03:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142353845 Vs