SLAC Magnetic Measurements Date: 11-17-2020 Time: 12:48:18 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_016_Cell_43_Upstairs Serial Number: PC97084 Run Number: 6 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 6 12:48:36 Ambient Measurement Device(s) Being Used, type = None 12:48:36 Magnet Voltage Measurement Device(s) Being Used, type = None 12:48:56 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:48:56 XMAG Device(s) Being Used, type = None 12:48:56 Ambient Measurement Device(s) Being Used, type = None 12:49:05   Voltage Measurement, V = 0.000000 V 12:49:05 Temperature Measurement, Probe Number = 0, T = 27.391000 C 12:49:06 Temperature Measurement, Probe Number = 1, T = 27.396000 C 12:49:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.39 P2 = 3458_Meas_Junction, Value = 27.40 12:49:06 Integrated Voltage Measurement... 12:49:32 Voltage Offset Correction: v_off_ini = 0.000004450 V, v_off_fin = 0.000005997 V 12:49:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142799354 Vs 12:49:32 Integrated Voltage Measurement... 12:50:06 Voltage Offset Correction: v_off_ini = 0.000006042 V, v_off_fin = 0.000005139 V 12:50:06 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142836932 Vs 12:50:07   Voltage Measurement, V = 0.000000 V 12:50:08 Temperature Measurement, Probe Number = 0, T = 27.379000 C 12:50:09 Temperature Measurement, Probe Number = 1, T = 27.396000 C 12:50:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.38 P2 = 3458_Meas_Junction, Value = 27.40 12:50:09 Integrated Voltage Measurement... 12:50:41 Voltage Offset Correction: v_off_ini = 0.000005116 V, v_off_fin = 0.000005810 V 12:50:41 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142841841 Vs 12:50:41 Integrated Voltage Measurement... 12:51:15 Voltage Offset Correction: v_off_ini = 0.000006100 V, v_off_fin = 0.000004769 V 12:51:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142819645 Vs 12:51:16   Voltage Measurement, V = 0.000000 V 12:51:17 Temperature Measurement, Probe Number = 0, T = 27.379000 C 12:51:17 Temperature Measurement, Probe Number = 1, T = 27.400000 C 12:51:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.38 P2 = 3458_Meas_Junction, Value = 27.40 12:51:17 Integrated Voltage Measurement... 12:51:49 Voltage Offset Correction: v_off_ini = 0.000005221 V, v_off_fin = 0.000007301 V 12:51:49 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142827174 Vs 12:51:49 Integrated Voltage Measurement... 12:52:20 Voltage Offset Correction: v_off_ini = 0.000006384 V, v_off_fin = 0.000003700 V 12:52:20 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142812681 Vs 12:52:21   Voltage Measurement, V = 0.000000 V 12:52:22 Temperature Measurement, Probe Number = 0, T = 27.381000 C 12:52:22 Temperature Measurement, Probe Number = 1, T = 27.392000 C 12:52:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.38 P2 = 3458_Meas_Junction, Value = 27.39 12:52:22 Integrated Voltage Measurement... 12:52:53 Voltage Offset Correction: v_off_ini = 0.000005044 V, v_off_fin = 0.000006066 V 12:52:53 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142836576 Vs 12:52:53 Integrated Voltage Measurement... 12:53:23 Voltage Offset Correction: v_off_ini = 0.000006066 V, v_off_fin = 0.000004041 V 12:53:23 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142810193 Vs 12:53:24   Voltage Measurement, V = 0.000000 V 12:53:25 Temperature Measurement, Probe Number = 0, T = 27.372000 C 12:53:26 Temperature Measurement, Probe Number = 1, T = 27.381000 C 12:53:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.37 P2 = 3458_Meas_Junction, Value = 27.38 12:53:26 Integrated Voltage Measurement... 12:54:02 Voltage Offset Correction: v_off_ini = 0.000005224 V, v_off_fin = 0.000007010 V 12:54:02 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142832637 Vs 12:54:02 Integrated Voltage Measurement... 12:54:33 Voltage Offset Correction: v_off_ini = 0.000006250 V, v_off_fin = 0.000004159 V 12:54:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142811337 Vs 12:54:34   Voltage Measurement, V = 0.000000 V 12:54:35 Temperature Measurement, Probe Number = 0, T = 27.364000 C 12:54:35 Temperature Measurement, Probe Number = 1, T = 27.374000 C 12:54:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.36 P2 = 3458_Meas_Junction, Value = 27.37 12:54:35 Integrated Voltage Measurement... 12:55:07 Voltage Offset Correction: v_off_ini = 0.000005008 V, v_off_fin = 0.000006367 V 12:55:07 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142834908 Vs 12:55:07 Integrated Voltage Measurement... 12:55:39 Voltage Offset Correction: v_off_ini = 0.000006232 V, v_off_fin = 0.000004136 V 12:55:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142820195 Vs 12:55:40   Voltage Measurement, V = 0.000000 V 12:55:41 Temperature Measurement, Probe Number = 0, T = 27.354000 C 12:55:41 Temperature Measurement, Probe Number = 1, T = 27.367000 C 12:55:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.35 P2 = 3458_Meas_Junction, Value = 27.37 12:55:41 Integrated Voltage Measurement... 12:56:14 Voltage Offset Correction: v_off_ini = 0.000004965 V, v_off_fin = 0.000006701 V 12:56:14 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142849639 Vs 12:56:14 Integrated Voltage Measurement... 12:56:46 Voltage Offset Correction: v_off_ini = 0.000006121 V, v_off_fin = 0.000004447 V 12:56:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142810951 Vs 12:56:47   Voltage Measurement, V = 0.000000 V 12:56:48 Temperature Measurement, Probe Number = 0, T = 27.351000 C 12:56:49 Temperature Measurement, Probe Number = 1, T = 27.352000 C 12:56:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.35 P2 = 3458_Meas_Junction, Value = 27.35 12:56:49 Integrated Voltage Measurement... 12:57:27 Voltage Offset Correction: v_off_ini = 0.000005273 V, v_off_fin = 0.000006773 V 12:57:27 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142842599 Vs 12:57:27 Integrated Voltage Measurement... 12:58:07 Voltage Offset Correction: v_off_ini = 0.000006139 V, v_off_fin = 0.000004100 V 12:58:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142820881 Vs 12:58:08   Voltage Measurement, V = 0.000000 V 12:58:09 Temperature Measurement, Probe Number = 0, T = 27.340000 C 12:58:09 Temperature Measurement, Probe Number = 1, T = 27.347000 C 12:58:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.34 P2 = 3458_Meas_Junction, Value = 27.35 12:58:09 Integrated Voltage Measurement... 12:58:40 Voltage Offset Correction: v_off_ini = 0.000005077 V, v_off_fin = 0.000006673 V 12:58:40 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142847355 Vs 12:58:40 Integrated Voltage Measurement... 12:59:15 Voltage Offset Correction: v_off_ini = 0.000006314 V, v_off_fin = 0.000005052 V 12:59:15 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142813097 Vs 12:59:16   Voltage Measurement, V = 0.000000 V 12:59:16 Temperature Measurement, Probe Number = 0, T = 27.339000 C 12:59:17 Temperature Measurement, Probe Number = 1, T = 27.350000 C 12:59:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.34 P2 = 3458_Meas_Junction, Value = 27.35 12:59:17 Integrated Voltage Measurement... 12:59:48 Voltage Offset Correction: v_off_ini = 0.000005284 V, v_off_fin = 0.000006073 V 12:59:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142820169 Vs 12:59:48 Integrated Voltage Measurement... 13:00:22 Voltage Offset Correction: v_off_ini = 0.000006056 V, v_off_fin = 0.000004542 V 13:00:22 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142814134 Vs