SLAC Magnetic Measurements Date: 09-09-2020 Time: 15:46:38 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_016_Cell_43_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 15:46:40 Ambient Measurement Device(s) Being Used, type = None 15:46:40 Magnet Voltage Measurement Device(s) Being Used, type = None 15:46:41 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:46:41 XMAG Device(s) Being Used, type = None 15:46:41 Ambient Measurement Device(s) Being Used, type = None 15:46:49   Voltage Measurement, V = 0.000000 V 15:46:49 Temperature Measurement, Probe Number = 0, T = 27.176000 C 15:46:50 Temperature Measurement, Probe Number = 1, T = 27.281000 C 15:46:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 27.28 15:46:50 Integrated Voltage Measurement... 15:47:23 Voltage Offset Correction: v_off_ini = 0.000004179 V, v_off_fin = 0.000004808 V 15:47:23 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142793376 Vs 15:47:23 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = 0.000004507 V, v_off_fin = 0.000003225 V 15:47:56 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142803689 Vs 15:47:57   Voltage Measurement, V = 0.000000 V 15:47:58 Temperature Measurement, Probe Number = 0, T = 27.148000 C 15:47:58 Temperature Measurement, Probe Number = 1, T = 27.279000 C 15:47:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.28 15:47:58 Integrated Voltage Measurement... 15:48:37 Voltage Offset Correction: v_off_ini = 0.000003760 V, v_off_fin = 0.000003930 V 15:48:37 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142811604 Vs 15:48:37 Integrated Voltage Measurement... 15:49:07 Voltage Offset Correction: v_off_ini = 0.000004758 V, v_off_fin = 0.000003245 V 15:49:07 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142795455 Vs 15:49:08   Voltage Measurement, V = 0.000000 V 15:49:09 Temperature Measurement, Probe Number = 0, T = 27.151000 C 15:49:09 Temperature Measurement, Probe Number = 1, T = 27.287000 C 15:49:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.29 15:49:10 Integrated Voltage Measurement... 15:49:41 Voltage Offset Correction: v_off_ini = 0.000003685 V, v_off_fin = 0.000005507 V 15:49:41 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142807602 Vs 15:49:41 Integrated Voltage Measurement... 15:50:13 Voltage Offset Correction: v_off_ini = 0.000004689 V, v_off_fin = 0.000004327 V 15:50:13 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142791680 Vs 15:50:14   Voltage Measurement, V = 0.000000 V 15:50:15 Temperature Measurement, Probe Number = 0, T = 27.150000 C 15:50:15 Temperature Measurement, Probe Number = 1, T = 27.287000 C 15:50:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.29 15:50:15 Integrated Voltage Measurement... 15:50:47 Voltage Offset Correction: v_off_ini = 0.000003646 V, v_off_fin = 0.000005111 V 15:50:47 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142801295 Vs 15:50:47 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = 0.000004657 V, v_off_fin = 0.000002415 V 15:51:17 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142787675 Vs 15:51:18   Voltage Measurement, V = 0.000000 V 15:51:19 Temperature Measurement, Probe Number = 0, T = 27.153000 C 15:51:19 Temperature Measurement, Probe Number = 1, T = 27.280000 C 15:51:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.28 15:51:19 Integrated Voltage Measurement... 15:51:53 Voltage Offset Correction: v_off_ini = 0.000003634 V, v_off_fin = 0.000005063 V 15:51:53 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142806032 Vs 15:51:53 Integrated Voltage Measurement... 15:52:45 Voltage Offset Correction: v_off_ini = 0.000004624 V, v_off_fin = 0.000003007 V 15:52:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142788364 Vs 15:52:47   Voltage Measurement, V = 0.000000 V 15:52:47 Temperature Measurement, Probe Number = 0, T = 27.152000 C 15:52:48 Temperature Measurement, Probe Number = 1, T = 27.279000 C 15:52:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.28 15:52:48 Integrated Voltage Measurement... 15:53:21 Voltage Offset Correction: v_off_ini = 0.000003892 V, v_off_fin = 0.000005079 V 15:53:21 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142810758 Vs 15:53:21 Integrated Voltage Measurement... 15:53:51 Voltage Offset Correction: v_off_ini = 0.000004605 V, v_off_fin = 0.000002852 V 15:53:51 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142789671 Vs 15:53:52   Voltage Measurement, V = 0.000000 V 15:53:53 Temperature Measurement, Probe Number = 0, T = 27.155000 C 15:53:53 Temperature Measurement, Probe Number = 1, T = 27.273000 C 15:53:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.27 15:53:53 Integrated Voltage Measurement... 15:54:23 Voltage Offset Correction: v_off_ini = 0.000003625 V, v_off_fin = 0.000003984 V 15:54:23 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142808028 Vs 15:54:23 Integrated Voltage Measurement... 15:55:12 Voltage Offset Correction: v_off_ini = 0.000004620 V, v_off_fin = 0.000002977 V 15:55:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142801637 Vs 15:55:13   Voltage Measurement, V = 0.000000 V 15:55:14 Temperature Measurement, Probe Number = 0, T = 27.146000 C 15:55:14 Temperature Measurement, Probe Number = 1, T = 27.277000 C 15:55:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.28 15:55:14 Integrated Voltage Measurement... 15:55:48 Voltage Offset Correction: v_off_ini = 0.000003742 V, v_off_fin = 0.000004947 V 15:55:48 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142811294 Vs 15:55:48 Integrated Voltage Measurement... 15:56:19 Voltage Offset Correction: v_off_ini = 0.000004835 V, v_off_fin = 0.000003046 V 15:56:19 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142797323 Vs 15:56:20   Voltage Measurement, V = 0.000000 V 15:56:20 Temperature Measurement, Probe Number = 0, T = 27.137000 C 15:56:21 Temperature Measurement, Probe Number = 1, T = 27.260000 C 15:56:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.14 P2 = 3458_Meas_Junction, Value = 27.26 15:56:21 Integrated Voltage Measurement... 15:56:54 Voltage Offset Correction: v_off_ini = 0.000003736 V, v_off_fin = 0.000005169 V 15:56:54 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142814332 Vs 15:56:54 Integrated Voltage Measurement... 15:57:24 Voltage Offset Correction: v_off_ini = 0.000004643 V, v_off_fin = 0.000004353 V 15:57:24 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142782221 Vs 15:57:25   Voltage Measurement, V = 0.000000 V 15:57:26 Temperature Measurement, Probe Number = 0, T = 27.135000 C 15:57:26 Temperature Measurement, Probe Number = 1, T = 27.259000 C 15:57:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.14 P2 = 3458_Meas_Junction, Value = 27.26 15:57:26 Integrated Voltage Measurement... 15:58:02 Voltage Offset Correction: v_off_ini = 0.000003447 V, v_off_fin = 0.000004849 V 15:58:02 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142812265 Vs 15:58:02 Integrated Voltage Measurement... 15:58:33 Voltage Offset Correction: v_off_ini = 0.000004378 V, v_off_fin = 0.000002916 V 15:58:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142795311 Vs