SLAC Magnetic Measurements Date: 03-10-2021 Time: 19:49:23 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_016_Cell_43_Upstairs Serial Number: PC97084 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral Measurement upstairs, Tunnel No Access for 5 days. Switch used Set 12 19:49:41 Ambient Measurement Device(s) Being Used, type = None 19:49:41 Magnet Voltage Measurement Device(s) Being Used, type = None 19:49:42 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 19:49:42 XMAG Device(s) Being Used, type = None 19:49:42 Ambient Measurement Device(s) Being Used, type = None 19:49:44   Voltage Measurement, V = 0.000000 V 19:49:45 Temperature Measurement, Probe Number = 0, T = 26.484000 C 19:49:45 Temperature Measurement, Probe Number = 1, T = 27.305000 C 19:49:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.48 P2 = 3458_Meas_Junction, Value = 27.30 19:49:46 Integrated Voltage Measurement... 19:50:12 Voltage Offset Correction: v_off_ini = 0.000006035 V, v_off_fin = 0.000007311 V 19:50:12 Integrated Voltage Measurement Delta Gap = 0.0040025 m VT = 0.142930461 Vs 19:50:12 Integrated Voltage Measurement... 19:50:48 Voltage Offset Correction: v_off_ini = 0.000006198 V, v_off_fin = 0.000004319 V 19:50:49 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142813722 Vs 19:50:50   Voltage Measurement, V = 0.000000 V 19:50:50 Temperature Measurement, Probe Number = 0, T = 26.463000 C 19:50:51 Temperature Measurement, Probe Number = 1, T = 27.297000 C 19:50:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.30 19:50:51 Integrated Voltage Measurement... 19:51:21 Voltage Offset Correction: v_off_ini = 0.000005128 V, v_off_fin = 0.000006943 V 19:51:21 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142847957 Vs 19:51:21 Integrated Voltage Measurement... 19:51:52 Voltage Offset Correction: v_off_ini = 0.000006167 V, v_off_fin = 0.000003881 V 19:51:52 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142821724 Vs 19:51:53   Voltage Measurement, V = 0.000000 V 19:51:54 Temperature Measurement, Probe Number = 0, T = 26.459000 C 19:51:55 Temperature Measurement, Probe Number = 1, T = 27.298000 C 19:51:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.30 19:51:55 Integrated Voltage Measurement... 19:52:29 Voltage Offset Correction: v_off_ini = 0.000005390 V, v_off_fin = 0.000005955 V 19:52:29 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142855068 Vs 19:52:29 Integrated Voltage Measurement... 19:53:08 Voltage Offset Correction: v_off_ini = 0.000006442 V, v_off_fin = 0.000005897 V 19:53:08 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142829272 Vs 19:53:09   Voltage Measurement, V = 0.000000 V 19:53:09 Temperature Measurement, Probe Number = 0, T = 26.459000 C 19:53:10 Temperature Measurement, Probe Number = 1, T = 27.300000 C 19:53:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.30 19:53:10 Integrated Voltage Measurement... 19:53:46 Voltage Offset Correction: v_off_ini = 0.000005300 V, v_off_fin = 0.000007334 V 19:53:46 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142854031 Vs 19:53:46 Integrated Voltage Measurement... 19:54:15 Voltage Offset Correction: v_off_ini = 0.000006408 V, v_off_fin = 0.000003875 V 19:54:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142825286 Vs 19:54:16   Voltage Measurement, V = 0.000000 V 19:54:17 Temperature Measurement, Probe Number = 0, T = 26.464000 C 19:54:18 Temperature Measurement, Probe Number = 1, T = 27.298000 C 19:54:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.30 19:54:18 Integrated Voltage Measurement... 19:54:52 Voltage Offset Correction: v_off_ini = 0.000005302 V, v_off_fin = 0.000006542 V 19:54:53 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142865324 Vs 19:54:53 Integrated Voltage Measurement... 19:55:26 Voltage Offset Correction: v_off_ini = 0.000006111 V, v_off_fin = 0.000003842 V 19:55:26 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142828295 Vs 19:55:27   Voltage Measurement, V = 0.000000 V 19:55:28 Temperature Measurement, Probe Number = 0, T = 26.457000 C 19:55:28 Temperature Measurement, Probe Number = 1, T = 27.292000 C 19:55:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.29 19:55:28 Integrated Voltage Measurement... 19:56:02 Voltage Offset Correction: v_off_ini = 0.000005185 V, v_off_fin = 0.000005753 V 19:56:02 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142850791 Vs 19:56:02 Integrated Voltage Measurement... 19:56:32 Voltage Offset Correction: v_off_ini = 0.000006283 V, v_off_fin = 0.000004709 V 19:56:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142826102 Vs 19:56:34   Voltage Measurement, V = 0.000000 V 19:56:34 Temperature Measurement, Probe Number = 0, T = 26.462000 C 19:56:35 Temperature Measurement, Probe Number = 1, T = 27.292000 C 19:56:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.46 P2 = 3458_Meas_Junction, Value = 27.29 19:56:35 Integrated Voltage Measurement... 19:57:08 Voltage Offset Correction: v_off_ini = 0.000005133 V, v_off_fin = 0.000007199 V 19:57:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142866689 Vs 19:57:08 Integrated Voltage Measurement... 19:57:41 Voltage Offset Correction: v_off_ini = 0.000006335 V, v_off_fin = 0.000004444 V 19:57:41 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142825940 Vs 19:57:42   Voltage Measurement, V = 0.000000 V 19:57:42 Temperature Measurement, Probe Number = 0, T = 26.468000 C 19:57:43 Temperature Measurement, Probe Number = 1, T = 27.293000 C 19:57:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.47 P2 = 3458_Meas_Junction, Value = 27.29 19:57:43 Integrated Voltage Measurement... 19:58:13 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = 0.000006946 V 19:58:14 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142859055 Vs 19:58:14 Integrated Voltage Measurement... 19:58:45 Voltage Offset Correction: v_off_ini = 0.000006379 V, v_off_fin = 0.000003685 V 19:58:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142826486 Vs 19:58:46   Voltage Measurement, V = 0.000000 V 19:58:46 Temperature Measurement, Probe Number = 0, T = 26.467000 C 19:58:47 Temperature Measurement, Probe Number = 1, T = 27.297000 C 19:58:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.47 P2 = 3458_Meas_Junction, Value = 27.30 19:58:47 Integrated Voltage Measurement... 19:59:17 Voltage Offset Correction: v_off_ini = 0.000005002 V, v_off_fin = 0.000006840 V 19:59:17 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142863206 Vs 19:59:17 Integrated Voltage Measurement... 19:59:49 Voltage Offset Correction: v_off_ini = 0.000006123 V, v_off_fin = 0.000003149 V 19:59:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142834726 Vs 19:59:50   Voltage Measurement, V = 0.000000 V 19:59:51 Temperature Measurement, Probe Number = 0, T = 26.468000 C 19:59:51 Temperature Measurement, Probe Number = 1, T = 27.298000 C 19:59:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.47 P2 = 3458_Meas_Junction, Value = 27.30 19:59:51 Integrated Voltage Measurement... 20:00:22 Voltage Offset Correction: v_off_ini = 0.000005139 V, v_off_fin = 0.000007381 V 20:00:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142877205 Vs 20:00:22 Integrated Voltage Measurement... 20:00:54 Voltage Offset Correction: v_off_ini = 0.000006297 V, v_off_fin = 0.000004333 V 20:00:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142832213 Vs