SLAC Magnetic Measurements Date: 01-06-2021 Time: 14:27:37 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47_Upstairs Serial Number: PC97084 Run Number: 8 Measurement Device: WalkerVs Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 8 14:27:55 Ambient Measurement Device(s) Being Used, type = None 14:27:55 Magnet Voltage Measurement Device(s) Being Used, type = None 14:27:56 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:27:56 XMAG Device(s) Being Used, type = None 14:27:56 Ambient Measurement Device(s) Being Used, type = None 14:28:12   Voltage Measurement, V = 0.000000 V 14:28:13 Temperature Measurement, Probe Number = 0, T = 27.785000 C 14:28:14 Temperature Measurement, Probe Number = 1, T = 26.902000 C 14:28:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.79 P2 = 3458_Meas_Junction, Value = 26.90 14:28:14 Integrated Voltage Measurement... 14:28:41 Voltage Offset Correction: v_off_ini = 0.000003929 V, v_off_fin = 0.000003915 V 14:28:41 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.142771979 Vs 14:28:41 Integrated Voltage Measurement... 14:29:46 Voltage Offset Correction: v_off_ini = 0.000004119 V, v_off_fin = 0.000001902 V 14:29:46 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142791136 Vs 14:29:47   Voltage Measurement, V = 0.000000 V 14:29:47 Temperature Measurement, Probe Number = 0, T = 27.765000 C 14:29:48 Temperature Measurement, Probe Number = 1, T = 26.894000 C 14:29:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.77 P2 = 3458_Meas_Junction, Value = 26.89 14:29:48 Integrated Voltage Measurement... 14:30:24 Voltage Offset Correction: v_off_ini = 0.000003014 V, v_off_fin = 0.000004851 V 14:30:24 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142822482 Vs 14:30:24 Integrated Voltage Measurement... 14:30:57 Voltage Offset Correction: v_off_ini = 0.000003926 V, v_off_fin = 0.000001456 V 14:30:58 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142785837 Vs 14:30:59   Voltage Measurement, V = 0.000000 V 14:30:59 Temperature Measurement, Probe Number = 0, T = 27.753000 C 14:31:00 Temperature Measurement, Probe Number = 1, T = 26.894000 C 14:31:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.89 14:31:00 Integrated Voltage Measurement... 14:31:31 Voltage Offset Correction: v_off_ini = 0.000002806 V, v_off_fin = 0.000004515 V 14:31:31 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142824084 Vs 14:31:31 Integrated Voltage Measurement... 14:32:04 Voltage Offset Correction: v_off_ini = 0.000004197 V, v_off_fin = 0.000002697 V 14:32:04 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142781776 Vs 14:32:05   Voltage Measurement, V = 0.000000 V 14:32:05 Temperature Measurement, Probe Number = 0, T = 27.751000 C 14:32:06 Temperature Measurement, Probe Number = 1, T = 26.899000 C 14:32:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.90 14:32:06 Integrated Voltage Measurement... 14:33:19 Voltage Offset Correction: v_off_ini = 0.000003547 V, v_off_fin = 0.000004284 V 14:33:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142830468 Vs 14:33:19 Integrated Voltage Measurement... 14:34:45 Voltage Offset Correction: v_off_ini = 0.000003847 V, v_off_fin = 0.000001094 V 14:34:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142788526 Vs 14:34:46   Voltage Measurement, V = 0.000000 V 14:34:47 Temperature Measurement, Probe Number = 0, T = 27.747000 C 14:34:47 Temperature Measurement, Probe Number = 1, T = 26.911000 C 14:34:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.91 14:34:47 Integrated Voltage Measurement... 14:35:28 Voltage Offset Correction: v_off_ini = 0.000003351 V, v_off_fin = 0.000004593 V 14:35:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142839514 Vs 14:35:28 Integrated Voltage Measurement... 14:36:04 Voltage Offset Correction: v_off_ini = 0.000003948 V, v_off_fin = 0.000002423 V 14:36:04 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142774803 Vs 14:36:05   Voltage Measurement, V = 0.000000 V 14:36:06 Temperature Measurement, Probe Number = 0, T = 27.746000 C 14:36:07 Temperature Measurement, Probe Number = 1, T = 26.909000 C 14:36:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.91 14:36:07 Integrated Voltage Measurement... 14:36:38 Voltage Offset Correction: v_off_ini = 0.000002867 V, v_off_fin = 0.000003794 V 14:36:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142828328 Vs 14:36:38 Integrated Voltage Measurement... 14:37:09 Voltage Offset Correction: v_off_ini = 0.000004325 V, v_off_fin = 0.000001811 V 14:37:10 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142777939 Vs 14:37:11   Voltage Measurement, V = 0.000000 V 14:37:11 Temperature Measurement, Probe Number = 0, T = 27.752000 C 14:37:12 Temperature Measurement, Probe Number = 1, T = 26.916000 C 14:37:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.92 14:37:12 Integrated Voltage Measurement... 14:37:42 Voltage Offset Correction: v_off_ini = 0.000002804 V, v_off_fin = 0.000003882 V 14:37:42 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142823130 Vs 14:37:42 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = 0.000004260 V, v_off_fin = 0.000003025 V 14:38:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142775838 Vs 14:38:15   Voltage Measurement, V = 0.000000 V 14:38:16 Temperature Measurement, Probe Number = 0, T = 27.753000 C 14:38:16 Temperature Measurement, Probe Number = 1, T = 26.918000 C 14:38:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.92 14:38:16 Integrated Voltage Measurement... 14:38:51 Voltage Offset Correction: v_off_ini = 0.000003004 V, v_off_fin = 0.000004387 V 14:38:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142831453 Vs 14:38:51 Integrated Voltage Measurement... 14:39:24 Voltage Offset Correction: v_off_ini = 0.000004201 V, v_off_fin = 0.000001196 V 14:39:24 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142791413 Vs 14:39:25   Voltage Measurement, V = 0.000000 V 14:39:25 Temperature Measurement, Probe Number = 0, T = 27.749000 C 14:39:26 Temperature Measurement, Probe Number = 1, T = 26.925000 C 14:39:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.93 14:39:26 Integrated Voltage Measurement... 14:40:00 Voltage Offset Correction: v_off_ini = 0.000003010 V, v_off_fin = 0.000004278 V 14:40:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142837705 Vs 14:40:00 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 0.000004469 V, v_off_fin = 0.000001937 V 14:41:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142774013 Vs 14:41:34   Voltage Measurement, V = 0.000000 V 14:41:35 Temperature Measurement, Probe Number = 0, T = 27.746000 C 14:41:35 Temperature Measurement, Probe Number = 1, T = 26.929000 C 14:41:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.75 P2 = 3458_Meas_Junction, Value = 26.93 14:41:35 Integrated Voltage Measurement... 14:42:25 Voltage Offset Correction: v_off_ini = 0.000003375 V, v_off_fin = 0.000004586 V 14:42:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142832945 Vs 14:42:25 Integrated Voltage Measurement... 14:42:56 Voltage Offset Correction: v_off_ini = 0.000004243 V, v_off_fin = 0.000001578 V 14:42:56 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142778410 Vs